– 17 –
SECTION  5
MECHANICAL  ADJUSTMENTS
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened
swab:
record/playback heads
pinch rollers
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head demagne-
tizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
• Torque Measurement
• Tape Tension Measurement
• Torque  Measurement
• Tape Tension  Measurement
Mode
Torque Meter
Meter Reading
Forward
CQ-102C
36 to 61g•cm
(0.50 – 0.84 oz•inch)
Forward
CQ-102C
2 to 6g•cm
Back Tension
(0.026 – 0.082 oz•inch)
Reverse
CQ-102RC
36 to 61g•cm
(0.50 – 0.84 oz•inch)
Reverse
CQ-102RC
2 to 6g•cm
Back Tension
(0.026 – 0.082 oz•inch)
FF, REW
CQ-201B
61 to 143g•cm
(0.85 – 1.98 oz•inch)
Mode
Tension Meter
Meter Reading
Forward
CQ-403A
more than 100 g (3.52 oz)
Reverse
CQ-403R
more than 100 g (3.52 oz)
0 dB=0.775 V
TAPE  DECK  SECTION
SECTION  6
ELECTRICAL  ADJUSTMENTS
1. Demagnetize the record/playback head with a head demagne-
tizer.  (Do not bring the head demagnetizer close to the erase
head.)
2. Do not use a magnetized screwdriver for the adjustments.
3. After the adjustments, apply suitable locking compound to the
parts adjust.
4. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
5. The adjustments should be performed in the order given in
this service manual.  (As a general rule, playback circuit ad-
justment should be completed before performing recording
circuit adjustment.)
6. The adjustments should be performed for both L-CH and R-
ch.
7. Switches and controls should be set as follows unless other-
wise specified.
8. Set to test mode.  (Press key switch same time
[SPECTRUM ANALYZER]
 
[ENTER]
  and  
[EFFECT]
  but-
ton.)
• Test Tape
Tape
Signal
Used for
P-4-A100
10 kHz, –10 dB
Azimuth Adjustment
WS-48B
3 kHz, 0 dB
Tape Speed Adjustment
P-4-L300
315 Hz, 0 dB
Level Adjustment
Record/ Playback Head Azimuth Adjustment
 DECK  A
 DECK  B
Note:
 Perform this adjustments for both decks
Procedure:
set
main board
CN207
Pin 
3
 (L-CH)
Pin 
1
 (R-CH)
main board
CN207
Pin 
2
 
+
level meter
test tape
P-4-A100
(10 kHz, –10 dB)
– 18 –
1. Mode:  Playback (FWD)
2. Turn the adjustment screw and check output peaks.  If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
3. Mode: Playback (FWD)
4. Repeat steps 1 to 3 in playback (REV) mode.
5. After the adjustments, apply suitable locking compound to the
pats adjusted.
Adjustment Location: Record/Playback Head (Deck A and B)
and MAIN board.
Screw
position
L-CH
peak
within
1dB
output
level
L-CH
peak
R-CH
peak
within
1dB
Screw
position
R-CH
peak
main
board
CN207
set
test tape
P-4-A100
(10 kHz, –10 dB)
pin 
1
oscilloscope
L-CH
R-CH
V
H
waveform of oscilloscope
in phase 45 
°
90 
°
135 
°
180 
°
good
wrong
pin 
2
pin 
3
L
R
reverse
forward
Tape Speed Adjustment 
DECK  A
Note:
Start the Tape Speed adjustment as below after setting to the test
mode.
In the test mode, the tape speed is high during pressing the
[H. SPEED DUBB]
 button.
Procedure:
1. Turn the power switch on.
2. Press the 
[SPECTRUM ANALYZER]
 button, 
[ENTER]
 but-
ton and 
[EFFECT]
 button simultaneously.
To exit from the test mode, press the
I /
u
button.
Mode: Playback (FWD)
1. Insert the WS-48B into the deck A and the blank tape into the
deck B.
2. Press the 
[REC]
 button and
· button on the deck B.  Then
the deck B is at recording mode.
3. Set the deck A to playback mode.
4. Keep pressing the 
[H. SPEED DUBB]
 button in playback mode.
Then at HIGH speed mode.
5. Adjust RV652 on the AUDIO board do that frequency counter
reads 6,000 ± 60 Hz.
6. Take off the 
[H. SPEED DUBB]
 button.
Then at NORMAL speed mode.
7. Adjust RV651 on the AUDIO  board so that frequency counter
reads 3,000 ± 20 Hz.
8. Frequency difference between deck  A and deck B the begin-
ning of the tape should be within ± 1.5%.
Adjustment Location: AUDIO and MAIN boards
Sample Value of Wow and flutter: 0.29% or less W. RMS
(WS-48B)
Playback level Adjustment
Procedure:
Mode: Playback (FWD)
Deck A is RV311 (L-CH) and RV411 (R-CH), Deck B is RV301
(L-CH) and RV401 (R-CH) so that adjustment within adjustment
level as follows.
Adjustment Level:
CN207 PB level: 301.5 to 338.3 mV (–8.2 to  –7.2 dB) level
difference between the channels: within ± 0.5 dB
Adjustment Location:  AUDIO and MAIN boards
+
set
test tape
WS-48B 
(3 kHz, 0 dB)
MAIN board
CN207 (Pin 
3
 : L-CH)
     (Pin 
1
 :R-CH)
frequency counter
 DECK  A
 DECK  B
+
set
test tape
P-4-L300
(315 Hz, 0 dB)
main board
CN207 (Pin 
3
: L-CH)
(Pin 
1
: R-CH)
level meter
– 19 –
Record bias Current Adjustment
Procedure:
1. Mode: Record
2. Mode:  Playback
Confirm playback the signal recorded in step 1 become adjustable
limits as follows.
If these levels do not adjustable limits, adjustment the RV341 (L-
CH) and RV441 (R-CH) on the AUDIO board to repeat steps 1
and 2.
Adjustable limits: Playback output of 315 Hz to playback output
of 10 kHz: 0 ± 0.5 dB
Adjustment Location: AUDIO and MAIN boards
Record Level Adjustment
Procedure:
1. Mode: Record
2. Mode: Playback
Confirm playback the signal recorded in step 1 become adjustable
limits as follows.
If these levels do not adjustable limits, adjustment the RV1501
(L-CH) and RV1551 (R-CH) on the MAIN board to repeat steps 1
and 2.
Adjustable limits:
CN207 PB level: 36.7 to 41.1 mV (–26.5 to –25.5 dB)
Adjustment Location:  MAIN board
 DECK  B
attenuator
set
Pin 
6
 (L-CH) of IC1501 on the MAIN board.
Pin 
 (R-CH) of IC1501 on the MAIN board.
1) 315 Hz
2) 10 kHz
50 mV (–23.8 dB)
Pin 
2
 (GND) of CN207 on the MAIN 
board.
600 
blank tape
CN-123
AF OSC
+
set
recorded
portion
CN207 (Pin 
3
: L-CH)
(Pin 
1
: R-CH)
level meter
 DECK  B
set
Pin 
6
  (L-CH) of IC1501 on the MAIN board.
Pin 
  (R-CH) of IC1501 on the MAIN board.
315 Hz, 50 mV (–23.8 dB)
blank tape
CS-123
Pin 
2
  (GND) of CN207 on the MAIN board.
600 
attenuator
AF OSC
+
set
recorded
portion
CN207 (Pin 
3
: L-CH)
(Pin 
1
: R-CH)
level meter
Adjustment Location:
[MAIN  BOARD] (Component Side)
[AUDIO  BOARD] (Conductor Side)
* As the adjustment parts is mounted on the component side, ad-
just it through a hole in the AUDIO board form conductor side.
(Except RV431, 441)
CN207
CN205
RECORD
LEVEL
IC1501
RV1501
RV1551
3
1
RV651
RV311 L
RV411 R
RV652
(NORMAL) (HIGH)
TAPE SPEED
PB
LEVEL
– DECK A –
– DECK B –
        
RECORD
BIAS CURRENT
RV341
RV441
RV301
RV401
L
R
PB LEVEL
R L
  
– 20 –
CD SECTION
Note:
1.
CD Block is basically designed to operate without adjustment.  There-
fore, check each item in order given.
2.
Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3.
Use an oscilloscope with more than 10M  impedance.
4.
Clean the object lens by an applicator with neutral detergent when the
signal level is low than specified value with the following checks.
Focus Bias check
Procedure:
1. Connect oscilloscope to test point TP (RF). (GND terminal:
VC)
2. Turned Power switch on.
3. Put disc (YEDS-18) in and playback.
4. Confirm that the shape “≈” can be clearly distinguished at the
center of the waveform and check the RF signal level.
•  RF signal
BD board
TP (FEO)
TP (VC)
+
oscilloscope
S Curve Check
Procedure:
1. Connect oscilloscope to test point TP (FEO).
2. Connect between test point TP (FOK) and GND by lead wire.
3. Turn Power switch on.
4.  Put disc (YEDS-18) in and turned Power switch on again and
actuate the focus search.  (actuate the focus search when disc
table is moving in and out.)
5. Check the oscilloscope waveform (S-curve) is symmetrical
between A and B.  And confirm peak to peak level within
3 ± 1 Vp-p.
6. After check, remove the lead wire connected in step 2.
Note:
• Try to measure several times to make sure than the ratio of A : B
or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the brightness to
obtain best waveform.
RF Level Check
Procedure:
1. Connect oscilloscope to test point TP (TEO) on BD board.
2. Turned Power switch on.
3. Put disc (YEDS-18) in to play the number five track.
4. Confirm that oscilloscope waveform is clear and check RF
signal level is correct or not.
•  SF signal
Note:
Clear RF signal waveform means that the shape “≈” can be clearly
distinguished at the center of the waveform.
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
level:
1.3 
±
 0.3 Vp-p
BD board
TP (FEO)
TP (VC)
+
oscilloscope
S-curve waveform
BD board
TP (RF)
TP (VC)
+
oscilloscope
A
B
symmetry
within 3 
±
 1 Vp-p
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
level:
1.3 
±
 0.3 Vp-p
Page of 78