— 21 —
2. Turn the adjustment screw and check output peaks.  If the peaks
do not match for L-CH and R-CH, turn the adjustment screw so
that outputs match within 1dB of peak.
3. Mode:  Playback (FWD)
4. Repeat steps 1 to 3 in playback (REV) mode.
5. After the adjustments, apply suitable locking compound to the
pats adjusted.
Adjustment Location: Record/Playback Head (Deck A and B)
and main board.
Tape Speed Adjustment
DECK  A
Notes:
• Start the Tape Speed adjustment as below after setting to the test
mode.
• In the test mode, the tape speed is high during pressing the
H. SPEED DUB  button.
Procedure:
1. Turn the power switch on.
2. Press the GROOVE button, ENTER/NEXT button and
DISC 4 button simultaneously.
To exit from the test mode, press the POWER button.
Mode:  Playback (FWD)
Deck A is RV311 (L-CH) and RV411 (R-CH), Deck B is RV301
(L-CH) and RV401 (R-CH) so that adjustment within adjustment
level as follows.
Adjustment Level:
CN207 PB level:  301.5 to 338.3 mV (–8.2 to  –7.2 dB) level
difference between the channels:  within ±0.5 dB
Adjustment Location:  AUDIO and main boards
1. Insert the WS-48B into the deck A and the blank tape into the
deck B.
2. Press the REC button and · button on the deck B.  Then
the deck B is at recording mode.
3. Set the deck A to playback mode.
4. Keep pressing the H. SPEED DUB button in playback mode.
Then at HIGH speed mode.
5. Adjust RV652 on the AUDIO board do that frequency counter
reads 6,000 ± 180 Hz.
6. Take off the H. SPEED DUB button.
Then at NORMAL speed mode.
7. Adjust RV651 on the AUDIO  board so that frequency counter
reads 3,000 ± 90 Hz.
8. Frequency difference between deck  A and deck B the beginning
of the tape should be within ± 1.5%.
Adjustment Location:  AUDIO board
Screw
position
L-CH
peak
within
1dB
output
level
L-CH
peak
R-CH
peak
within
1dB
Screw
position
R-CH
peak
main
board
CN207
set
test tape
P-4-A100
(10kHz, –10dB)
pin 
3
oscilloscope
L-CH
R-CH
V
H
waveform of oscilloscope
in phase 45
°
90
°
135
°
180
°
good
wrong
pin 
2
pin 
1
L
R
reverse
forward
+
set
test tape
WS-48B 
(3 kHz, 0 dB)
main board
CN207 (Pin 
1
 : L-CH)
     (Pin 
3
 :R-CH)
frequency counter
+
set
test tape
P-4-L300
(315 Hz, 0 dB)
main board
CN207 (Pin 
1
: L-CH)
(Pin 
3
: R-CH)
level meter
Sample Value of Wow and flutter
W.RMS (JIS) within 0.3%
(test tape: WS-48B)
Playback level Adjustment
DECK A
DECK B
Procedure:
Mode:  Playback (FWD)
— 22 —
Record Bias Current Adjustment
DECK B
Procedure:
1. Mode:  record
2. Mode:  Playback
Confirm playback that the signal recorded in step 1 becomes adjustable
limits as follows.
If these levels are not adjustable limits, adjust the RV341 (L-CH) and
RV441 (R-CH) on the AUDIO board to repeat steps 1 and 2.
Adjustable limits: Playback output of 315 Hz to playback output
of 10kHz:  0±0.5 dB
Adjustment Location: AUDIO and main boards
Record Level Adjustment   DECK B
Procedure:
1. Mode:  record
2. Mode:  Playback
Confirm playback that the signal recorded in step 1 becomes
adjustable limits as follows.
If these levels are not adjustable limits, adjust the RV1501 (L-CH)
and RV1551 (R-CH) on the main board to repeat steps 1 and 2.
Adjustable limits:
CN207 PB level:  47.3 to 53.1 mV (–24.3 to –23.3 dB)
Adjustment Location:  main board
[MAIN  BOARD] (Component Side)
[AUDIO  BOARD]  (Conductor Side)
attenuator
set
Pin 
6
 (L-CH) of IC1501 on the main board.
Pin 
 (L-CH) of IC1501 on the main board.
1) 315 Hz
2) 10 kHz
50 mV (–23.8 dB)
Pin 
2
 (GND) of ICN207 on the main board.
600 
blank tape
CN-123
AF OSC
+
set
recorded
portion
CN207 (Pin 
1
: L-CH)
(Pin 
3
: R-CH)
level meter
set
Pin 
6
  (L-CH) of IC1501 on the main board.
Pin 
  (R-CH) of IC1501 on the main board.
315 Hz, 50 mV (–23.8 dB)
blank tape
CS-123
Pin 
2
  (GND) of CN207 on the main board.
600 
attenuator
AF OSC
+
set
recorded
portion
CN207 (Pin 
1
: L-CH)
(Pin 
3
: R-CH)
level meter
RV1501
IC1501
CN205
CN207
RV1551
RECORD LEVEL
IC301
IC201
RECORD
BAIS
TAPE SPEED
(NORMAL)
RV651
®
(HIGH)
RV652
®
RV311
®
RV411
®
PB
LEVEL
RV441 RV341
RV301
®
L
RV401
®
R
R
L
– DECK B –
– DECK A –
PB LEVEL
    
— 23 —
CD SECTION
Note:
1. CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.
2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M
 impedance.
4. Clean the object lens by an applicator with neutral detergent when the
signal level is low than specified value with the following checks.
5. Adjust the focus bias adjustment when optical block is replaced.
Focus Bias check
Procedure:
1. Connect oscilloscope to test point TP (RF). (GND terminal :
VC)
2. Turned Power switch on.
3. Put disc (YEDS-18) in and playback.
4. Confirm that the shape “
” can be clearly distinguished at the
center of the waveform and check the RF signal level.
•  RF signal
S Curve Check
Procedure:
1. Connect oscilloscope to test point TP (FEO).
2. Connect between test point TP (FOK) and GND by lead wire.
3. Turn Power switch on.
4.  Put disc (YEDS-18) in and turned Power switch on again and
actuate the focus search.  (actuate the focus search when disc
table is moving in and out.)
5. Check the oscilloscope waveform (S-curve) is symmetrical
between A and B.  And confirm peak to peak level within 3±1
Vp-p.
S-curve waveform
6. After check, remove the lead wire connected in step 2.
Notes:
• Try to measure several times to make sure than the ratio of A : B
or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the brightness
to obtain best waveform.
RF Level Check
•  RF signal
+
BD board
TP (RF)
VC
oscilloscope
(DC range)
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
level:
1.3 
±
 0.3Vp-p
+
BD board
TP (FEO)
TP (VC)
oscilloscope
A
B
symmetry
within 3 
±
 1 Vp-p
Procedure:
1. Connect oscilloscope to test point TP (RF) on BD board.
2. Turned Power switch on.
3. Put disc (YEDS-18) in and playback.
4. Confirm that oscilloscope waveform is clear and check RF signal
level is correct or not.
Note:
  
Clear RF signal waveform means that the shape “
≈” can be
clearly distinguished at the center of the waveform.
+
BD board
TP (RF)
TP (VC)
oscilloscope
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
level:
1.3 
±
 0.3Vp-p
— 24 —
E-F Balance (1 Track Jump) check
(Without remote commander)
Procedure:
1. Connect oscilloscope to test point TP (TEO) on BD board.
2. Turned Power switch on.
3. Put disc (YEDS-18) in to play the number five track.
4. Press the “P (Pause)” button.  (Becomes the 1 track jump mode)
5. Check the level B of the oscilloscope's waveform and the A
(DC voltage) of the center of the Traverse waveform.
Confirm the following:
A – B
2 (A + B)  
×
 100 = ±7 (%)
+
BD board
TP (TEO)
TP (VC)
oscilloscope
Center of the waveform
B
level : 500 mV 
±
 100 mVp-p
symmetry
A (DC voltage)
0V
Adjustment Location:
IC103
CNU102
IC101
IC
I02
TP
(RF)
TP
(FOK)
TP
(VC)
TP (FEO)
TP (TEO)
TP
(GND)
CNU101
1 track jump waveform
[BD BOARD]  (Conductor Side)
Page of 80
Display