13
HCD-VX555/VX555J
* Tape function
1. When a tape is inserted in Deck B and recording is started, the
input source function selects VIDEO automatically.
When  CD SYNC/HI-DUB  button is pressed during Rec in
function, ALC is turned on.
2.   When   x  button is pressed to stop recording, the Tape (Deck)
B is selected and tape is rewound, tape is rewound using  m
button, tape is stops at around the record-starting position and
playback of the recorded portion of the tape is started.  If PAUSE
is inserted even once during recording, tape is rewound to the
position around the PAUSE position and is played back.
3.
When  CD SYNC / HI-DUB  button is pressed during playback
of Deck B, either normal speed or high speed can be selected
by this button.
* AMS Test Mode
1.
Set TAPE function
2.
Select the desired loop by pressing the  PLAY MODE  button.
Insert a test tape AMS-110A or AMS-120 to Deck A.
3.
Press the  SPECTRUM  button to enter the AMS test mode.
4.
After a tape is rewound first, the FF AMS is checked, and the
mechanism is shut off after detecting the AMS signal twice.
5.
Then the REW AMS is checked and the mechanism is shut off
after detecting the AMS signal twice.
6.
When the check is complete, a message of either OK or NG
appears.
* To return to normal mode again.
1.
When you want to exit this mode, press the  ?/1  button.
2.     The cold reset is enforced at the same time.
[VACS ON/OFF Mode]
• This mode is used to switch ON and OFF the VACS (Variable
Attenuation Control System).
Procedure:
Press the  ENTER  and  SPECTRUM  buttons simultaneously.  The
message “VACS OFF” or “VACS ON” appears.
[CD Aging Mode]
Procedure:
1.
Short SL501 by soldering.
2.
Turn on the main power.  Set a disc on the DISC1 tray.  Select
CD.
3.
Press the  SELECT/gG  button.  The aging mode starts.
4.
Aging status appears on the monitor screen.
How to exit the CD aging mode:
1.
Press the  ?/1   and turn off the main power.
2.
Remove soldering from SL501.
[Function Change Mode]
Select either VIDEO or MD of the external FUNCTION input.
Procedure:
1.
Turn on the power.
2.
Press the two buttons  ENTER  and  ?/1  at the same time.
The main power is turned on and the other function of the
previous function is selected and displayed.  “MD” or
“VIDEO”.
[VIDEO CD Color-bars Mode]
On this mode, the data of the color-bars signal as a picture signal
and the 1 kHz sine wave signal as a sound signal are output by the
mechanism controller (IC502) for the video CD signal check.  When
measurement of the voltage and waveform on the VIDEO board,
perform it in this mode.
For reference, the color-bars signal can be observed at CN301 pin2
using an oscilloscope.
Procedure:
1. Short the both ends of the land of SL503 of the VIDEO board.
2. Turn the power on. Press the  CD  button to select CD.
3. The color-bars appears when the CD is in stop status, and it
disappears when the CD goes in play status.
4. After measuring, remove the lead wire connected.VIDEO board
(SIDE B)
[CD Servo ON/OFF Mode]
Procedure:
1.
Short SL502 on the VIDEO board by soldering.
2.
Turn on the main power.  Set a disc on the DISC1 tray.  Select
CD.
3.
Press the hH button to play back CD.
4.
When the  > +  button is pressed, 100 track jump is executed.
5.
Also, every pressing of the PLAY MODE button triggers
between  ON and OFF of TRACKING SERVO and SLED
SERVO.
How to quit the CD servo ON/OFF mode:
1.
Press the  ?/1  button to turn off the main power.
2.
Remove soldering from SL502.
[CD Ship Mode (Memory Clear) ]
• This mode moves the pickup to the position durable to vibra-
tion. Use this mode when returning the set to the customer after
repair.
Procedure:
1. Press
1/u button to turn the set ON.
2. Press  three  buttons  x  , ENTER and GAME  simultaneously.
3. After the "STANDBY" display blinks six times, a message
“LOCK” is displayed on the fluorescent indicator tube, and the
CD ship mode is set.
[CD Ship Mode (No Memory Clear) ]
• This mode moves the pickup to the position durable to vibra-
tion. Use this mode when returning the set to the customer after
repair.
Procedure:
1. Press
1/u button to turn the set ON.
2. Press  CD  button and  
1/u   button simultaneously.
3. After the "STANDBY" display blinks six times, a message
“LOCK” is displayed on the fluorescent indicator tube, and the
CD ship mode is set.
TOC reading
Last track is played back
First track is played back
OPEN
CLOSE
Monitor Display
1st line
OPEN/CLOSE/CD PLAY display
2nd line
DISC1/DISC1-15/DISC1-1/TIME display
4th line
COUNT : 1 display
5th line
TOTAL ERR : 00 display
6th line
JITTER FF display
3rd line
AGING
Ver 1.3  2002.07
14
HCD-VX555/VX555J
[ VIDEO BOARD ] (SIDE A)
J301
CN501
CN301
1  2  3
CN503
SL503
SL502
SL501
CHECK LED
CN502
15
HCD-VX555/VX555J
SECTION 4
MECHANICAL ADJUSTMENTS
SECTION 5
ELECTRICAL ADJUSTMENTS
0 dB=0.775 V
DECK  SECTION
1. Demagnetize the record/playback head with a head
demagnetizer.
2. Do not use a magnetized screwdriver for the adjustments.
3. After the adjustments, apply suitable locking compound to the
parts adjust.
4. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
5. The adjustments should be performed in the order given in this
service manual.  (As a general rule, playback circuit adjustment
should be completed before performing recording circuit
adjustment.)
6. The adjustments should be performed for both L-CH and R-
CH.
7. Switches and controls should be set as follows unless otherwise
specified.
• Test Tape
Record/Playback Head Azimuth Adjustment
Tape
Signal
Used for
P-4-A100
10 kHz, –10 dB
Azimuth Adjustment
WS-48B
3 kHz, 0 dB
Tape Speed Adjustment
P-4-L300J
315 Hz, 0 dB
Level Adjustment
DECK A      DECK B
Note:
  Perform this adjustments for both decks
Procedure:
1. Mode:  Playback
Precaution
1. Clean the following parts with a denatured alcohol-moistened
swab:
record/playback heads
pinch rollers
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head
 demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
Torque Measurement
set
MAIN board
CN301
Pin 
3
 (L-CH)
Pin 
1
 (R-CH)
MAIN board
CN301
Pin 
2
 (GND)
+
level meter
test tape
P-4-A100
(10 kHz, –10 dB)
3.06 N • m to 6.96 N • m
31 to 71 g • cm
(0.43 – 0.98 oz • inch)
0.19 N • m to 0.58 N • m
2 to 6 g • cm
(0.02 – 0.08 oz • inch)
3.06 N • m to 6.96 N • m
31 to 71 g • cm
(0.43 – 0.98 oz • inch)
0.19 N • m to 0.58 N • m
2 to 6 g • cm
(0.02 – 0.08 oz • inch)
6.96 N • m to 14.02 N • m
71 to 143 g • cm
(0.98 – 1.99 oz • inch)
9.80 N • m
100 g or more
(3.53 oz or more)
9.80 N • m
100 g or more
(3.53 oz or more)
Mode
Torque meter
CQ-102C
CQ-102C
CQ-102RC
CQ-102RC
CQ-201B
CQ-403A
CQ-403R
Meter reading
FWD
FWD
back tension
REV
REV
back tension
FF/REW
FWD tension
REV tension
16
HCD-VX555/VX555J
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
3. Mode:  Playback
4. After the adjustments, apply suitable locking compound to the
pats adjusted.
Tape Speed Adjustment
DECK B
Note:
Start the Tape Speed adjustment as below after setting to the test
mode.
In the test mode, the tape speed is high during pressing the
 CD SYNC/HI-DUB 
 button.
Procedure:
1. Turn the power switch on.
2. Press the x button,  ENTER  button and  DISC 3  button
simultaneously.
(The “TEST MODE” on the fluorescent indicator tube display
while in the test mode.)
To exit from the test mode, press the ?/1 button.
Mode:  Playback
1. Insert the WS-48B into the deck B.
2. Press the gG button on the deck B.
3. Press the  CD SYNC/HI-DUB  button in playback mode.
Then at HIGH speed mode.
4. Adjust RV1001 on the LEAF SW board so that frequency
counter reads 6,000 
± 30 Hz.
5. Press the  CD SYNC/HI-DUB  button.
Then back to NORMAL speed mode.
6. Adjust RV1002 on the LEAF SW board so that frequency
counter reads 3,000 
± 15 Hz.
Adjustment Location:  LEAF SW board
Playback level Adjustment
DECK A      DECK B
Procedure:
Mode:  Playback
1. Confirm that level difference between the channels is with 
±
0.5 dB.
2. After check, adjust the following RVs.
Deck A is RV302 (L-CH), Deck B is RV303 (L-CH) so that
adjustment within adjustment level as follows.
Adjustment Level:
CN301 PB level:  334.4 to 748.7 mV (–7.3 to  –0.3 dB)
Adjustment Location:  MAIN board
Sample Volue of Wow and Flutter: 0.3% or less W. RMS
(WS-48B)
Screw
position
L-CH
peak
within
1dB
Output
level
L-CH
peak
R-CH
peak
within
1dB
Screw
position
R-CH
peak
MAIN
board
CN301
set
test tape
P-4-A100
(10 kHz, –10 dB)
pin 
1
oscilloscope
L-CH
R-CH
V
H
waveform of oscilloscope
in phase 45
°
90
°
135
°
180
°
good
wrong
pin 
2
pin 
3
L
R
+
set
test tape
WS-48B 
(3 kHz, 0 dB)
MAIN board
CN301 (Pin 
3
 : L-CH)
(Pin 
1
 : R-CH)
frequency counter
+
set
test tape
P-4-L300J
(315 Hz, 0 dB)
MAIN board
CN301 (Pin 
3
: L-CH)
(Pin 
1
: R-CH)
level meter
forward
reverse
Page of 85
Display

Click on the first or last page to see other HCD-VX555 / HCD-VX555J / MHC-VX555 / MHC-VX555J service manuals if exist.