HCD-VP100
10
2-6.
CD  MECHANISM  DECK (CDM55F-K6BD42A), MPEG  BOARD
2-7.
BASE  UNIT (BU-K6BD42A)
4
two screws
(BTP3 
×
 8)
7
three screws
(DIA.2.6 
×
 8)
3
connector
(CN503)
3
connector
(CN504)
9
two screws
(DIA.2.6 
×
 8)
0
bracket (MPEG)
8
MPEG board
qa
CD mechanism deck
(CDM55F-K6BD42A)
5
2
connector
(CN401)
1
flexible flat cable 
(19core) (CN101)
6
flexible flat cable 
(24core) (CN501)
1
floating screw
(PTPWHM2.6)
2
base unit
(BU-K6BD42A)
HCD-VP100
11
2-8.
LOADING  BOARD
2-9.
CAM (CDM55)
2
belt (CDM55)
B
3
Pull the tray 
with pushing 
B
.
4
two screws
(BTP2.6 
×
 6)
5
LOADING board
1
Rotate the gear(B) in
the direction of arrow 
A
.
A
2
lever (SW)
1
torsion spring
6
gear (B)
3
spacer (55)
4
pulley (LDG)
5
gear (A)
7
roller
8
cam (CDM55)
HCD-VP100
12
SECTION  3
TEST  MODE
Start
REC pause for 3 seconds
FWD REC
Fast forward
REV Play
REC pause for 3 seconds
REV REC
Rewind
FWD Play
Shut off
Shut off
Shut off
Shut off
1 minute
3 minutes
1 minute
3 minutes
Start
Open the disc tray
Close the disc tray
Play the last track
[Cold Reset]
• The cold reset clears all data including preset data stored in the
RAM to initial conditions. Execute this mode when returning
the set to the customer.
Procedure:
1. Turn ON the power.
2. Press three buttons
x
(TAPE), 
x
(CD), and 
[BAND]
simultaneously.
3. The set is reset.
[Liquid Crystal Display All Lit Check Mode]
Procedure:
1.
Set to standby state.
2.
Press three buttons of
x
(TAPE),
x
 (CD), and
[TUNING MODE]
 simultaneously.
3.
Liquid crystal display are all turned on.
4.
To exit from this mode, press the
I/1
button to turn the power
OFF.
[Tape Deck Aging Mode]
This mode can be used for operation check of tape deck section.
Procedure:
1.
Set a tape in the tape deck.
2.
Set to standby state.
3.
Press three buttons of
x
(TAPE),
x
 (CD), and 
[TUNING +]
simultaneously.
4.
The aging is executed in bellow sequence.
5.
To exit from the aging mode, press the
I/1
button to turn the
power OFF.
Aging mode sequence:
[CD Aging Mode]
This mode can be used for operation check of CD section.
Procedure:
1.
Load a CD disc.
2.
Set to standby state.
3.
Press three buttons of
x
(TAPE),
x
(CD), and 
[TUNING --]
simultaneously.
4.
The aging is executed in bellow sequence.
5.
To exit from the aging mode, press the
I/1
button to turn the
power OFF.
Aging mode sequence:
HCD-VP100
13
13
2.
Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
3.
Mode: Playback
4.
Repeat step 1 to 3 in playback (REV) mode.
5.
After the adjustments, apply suitable locking compound to the
pats adjusted.
Adjustment Location:
SECTION  4
ELECTRICAL  ADJUSTMENTS
0 dB=0.775 V
DECK  SECTION
Tape
Signal
Used for
P-4-A100
10 kHz, –10 dB
Azimuth Adjustment
WS-48B
3 kHz, 0 dB
Tape Speed Adjustment
P-4-L300
315 Hz, 0 dB
Level Adjustment
Note:
Confirm each contents of this section first of all. If the results are
not satisfied, do the adjustment.
1.
Demagnetize the record/playback head with a head
demagnetizer.
2.
Do not use a magnetized screwdriver for the adjustments.
3.
After the adjustments, apply suitable locking compound to the
parts adjust.
4.
The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
5.
The adjustments should be performed in the order given in this
service manual.  (As a general rule, playback circuit adjustment
should be completed before performing recording circuit
adjustment.)
6.
The adjustments should be performed for both L-CH and R-
CH.
7.
Switches and controls should be set as follows unless otherwise
specified.
• Test Tape
Record/Playback Head Azimuth Adjustment
Procedure:
1.
Mode:  Playback
set
MAIN board
SPEAKER terminals (SJ301)
L-CH, R-CH
+
level meter
test tape
P-4-A100
(10 kHz, –10 dB)
Screw
position
L-CH
peak
within
1 dB
Output
level
L-CH
peak
R-CH
peak
within
1 dB
Screw
position
R-CH
peak
MAIN
board
CN301
set
test tape
P-4-A100
(10 kHz, –10 dB)
R-CH
oscilloscope
L-CH
R-CH
V
H
waveform of oscilloscope
in phase 45
°
90
°
135
°
180
°
good
wrong
MAIN board
SPEAKER terminals (SJ301)
L-CH
forward
reverse
CD SECTION
Notes:
1. CD block basically constructed to operate without adjustment.  There-
fore, check each item in order given.
2. Use YEDS-18 disc (Part No.: 3-702-101-01) unless otherwise indicated.
3. Use the oscilloscope with more than 10 M
 impedance.
4. Clean an object lens by an applicator with neutral detergent when the
signal level is low than specified value with the following checks.
S-Curve Confirmation
Connection:
Procedure:
1. Connect an oscilloscope to IC703 pin qg and TP (VC) on the
CD board.
2. Connect between TP (FOK) and TP (GND) on the CD board
by lead wire.
3. Turn the power ON.
4. Press the
 [EJECT    ]
 (CD) button to open the disc tray, and
put the disc (YEDS-18).
5. Press the 
[EJECT    ]
 (CD) button to close the disc tray (Actu-
ate the focus search).
6. Confirm that the waveform on the oscilloscope is symmetrical
between A and B and that peak to peak level is within 3.0 
±
1.0 Vp-p.
S-curve waveform
7. After confirmation, disconnect the lead wire in step 2.
Note:
• Try to measure several times to make sure that the ratio of A : B
or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the brightness
to obtain best waveform.
RF Level Confirmation
Connection:
Procedure:
1. Connect an oscilloscope to IC703 pin qh and TP (VC) on the
CD board.
2. Turn the power ON.
3. Load the disc (YEDS-18), and press the 
[    ]
 button to play-
back the disc.
4. Confirm that the waveform on the oscilloscope is clear and
that the RF signal level is correct.
Note:
Clear RF signal waveform means that the shape “
” can be clearly
distinguished at the center of the waveform.
+
CD board
IC703 pin qg
TP (VC)
oscilloscope
+
CD board
IC703 pin qh
TP (VC)
oscilloscope
(AC range)
RF signal waveform
When observing the eye pattern, set the oscilloscope for AC range
and raise vertical sensitivity.
Connecting Location:
– CD  Board (Conductor Side) –
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
(with the 10: 1 probe 
in use)
level: 1.3        Vp-p
+0.25
–0.20
Z
within 3.0 
±
 1.0 Vp-p
A
B
symmetry
TP (GND)
TP (VC)
TP (FOK)
20
11
1
10
CN701
IC701
IC703
u
Z
Page of 47