Sony HCD-SHAKE5 / HCD-SHAKE6D (serv.man2) Service Manual ▷ View online
HCD-SHAKE5/SHAKE6D
13
[HISTORY MODE]
This mode is used to check important data stored in the system
when PROTECTOR happen.
This mode is used to check important data stored in the system
when PROTECTOR happen.
Procedure:
1. During demo mode, press [ENTER] button and [LED
PATTERN] for 5 seconds to mode in to history mode.
2. Press the [M >
/TUNING+] (SHAKE5) / [TUNING +/
>] (SHAKE6D) or [
.m/TUNING‒] (SHAKE5) /
[TUNING‒/.] (SHAKE6D) button to check history data
stored.
stored.
To release from History Mode.
To release from this mode, press [
To release from this mode, press [
\/1
] button.
Display on fl uorescent indicator tube
Description
P
R
O
C
O
U
N
T
※ ※
No of time protector happen (0 ~ 99)
P
R
O
T
Y
P
E
※ ※ ※ ※
Indication protector type (refer protector kind test mode)
Protector type
Protector Error Code
AMPL
E01
PWR2
E03
SPK
E04
TEMP
E05
FAN
E06
T
1
※ ※ ※ ※ ※
H
※ ※
M
Single Power On Time until protector happened
(0~99999 hours, 0~99Min)
(0~99999 hours, 0~99Min)
T
2
※ ※ ※ ※ ※
H
※ ※
M
Total Power On Time [ no consider protector happen ]
(0~99999 hours, 0~99Min)
(0~99999 hours, 0~99Min)
F
U
N
C
※ ※ ※ ※ ※ ※ ※
Input Function during protector happened
V
O
L
※ ※ ※
Volume setting (MIN / 1 - 50 / MAX)
A
T
T
※ ※ ※
Actual attenuation (-87 … 0)
E
Q
L
O
W
※ ※ ※
Low EQ level (-6 … 0 … +6)
E
Q
M
I
D
※ ※ ※
Mid EQ level (-6 … 0 … +6)
E
Q
H
I
G
H
※ ※ ※
High EQ level (-6 … 0 … +6)
V
A
C
S
※ ※
VACS level (0 ... 5)
A
P
V
A
C
S
※ ※
AP VACS level (0 … 7)
S
U
R
R
※ ※ ※
Surround setting (OFF / ON)
D
J
※ ※ ※ ※ ※ ※
※ ※
DJ Effect setting
DJ Mode: OFF/ISOLAT/FLANGE/PHASER/FLASH
DJ Setting Value: 1~ 40
DJ Mode: OFF/ISOLAT/FLANGE/PHASER/FLASH
DJ Setting Value: 1~ 40
B
A
Z
U
C
A
※ ※ ※
Bass Bazuca setting (OFF / ON)
HCD-SHAKE5/SHAKE6D
14
[MODEL & DEST WRITE MODE]
This mode is used to set software model & destination.
This mode is only available when no permanent model &
destination is stored.
This mode is used to set software model & destination.
This mode is only available when no permanent model &
destination is stored.
Procedure:
1. Press [OPTIONS] (SHAKE5) / [X] (SHAKE6D) button and
[FOOTBALL] button simultaneously and hold for 5 seconds.
2. Fluorescent indicator tube display will show “M XXXXX”.
3. Press
3. Press
[+ /
] (SHAKE5) / [+/PRESET+] (SHAKE6D) /
[‒ /
] (SHAKE5) / [‒/PRESET‒] (SHAKE6D) button to
select the model based on the set’s model.
Product Code
F. Tube display
STORM-JR-CD
“M STORM-JR”
STORM-JR-DVD
“M STORM-JRD”
4. Press [ENTER] button.
5. Fluorescent indicator tube display will show “D XXXXX”.
6. Press
5. Fluorescent indicator tube display will show “D XXXXX”.
6. Press
[+ /
] (SHAKE5) / [+/PRESET+] (SHAKE6D) /
[‒ /
] (SHAKE5) / [‒/PRESET‒] (SHAKE6D) button to
select the destination based on the set’s country.
Area Code Country
F. Tube display
J1
Japan
“D J”
JE1
Tourist
“D JE”
U2/CA2
America, Canada
“D NA”
CEL/CE1/
CE2
CE2
Europe (general)
“D CE2”
CEK
U.K.
“D CEK”
RU1/RU3
Russia
“D RU”
AU1
Australia
“D AU”
CN1
China
“D CN”
E12
India, Pakistan, Morocco
“D E12”
E3/E93/
SA2/E15
SA2/E15
Middle East, Africa
(South Africa), Iran
(South Africa), Iran
“D E3”
E4
Africa
“D E12”
EA3
Saudi Arabia
“D EA3”
HK1/
HK2/PL1/
SP1/SP2/
SP6/TH1
HK2/PL1/
SP1/SP2/
SP6/TH1
Hong Kong, Philippines,
Singapore, Malaysia,
Thailand
Singapore, Malaysia,
Thailand
“D ASIA”
KR2
Korea
“D KR”
TW2
Taiwan
“D TW”
E2, E32,
E51, AR2
E51, AR2
Latin America (general),
Chile, Peru, Argentina
Chile, Peru, Argentina
“D LATIN”
BR1
Brazil
“D BR”
MX2,
MX4
MX4
Mexico
“D MX”
7. Press [ENTER] button to confi rm the selection.
8. “RESET” appears on the fl uorescent indicator tube. After that,
8. “RESET” appears on the fl uorescent indicator tube. After that,
the fl uorescent indicator tube becomes blank for a while, and
the system is reset.
the system is reset.
9. Mode in [PANEL TEST MODE] again to confi rm on the
model & destination.
[PROTECT KIND CHECK TEST MODE]
This mode is used to check types of protect occurred during
protector on.
This mode is used to check types of protect occurred during
protector on.
Procedure:
1. During
protection
on,
fl uorescent indicator tube shows blinking
message “PROTECT EXX” where “EXX” represent the error
code.
code.
2. Press
[] button and [‒ /
] (SHAKE5) / [‒/PRESET‒]
(SHAKE6D) button simultaneously.
3. Fluorescent indicator tube display will toggle between
“PROTECT” message and protector kind message display.
Below table explains on protector kind.
Error
Code
Code
Protector
Message
Message
Description
E01
“AMP OCP”
The over current condition to
MOSFET occurs by defect of
MOSFET or defect of PS output
line.
MOSFET occurs by defect of
MOSFET or defect of PS output
line.
E03
“POWER
SUPPLY”
SUPPLY”
Defect of power supply circuit
to AMP
to AMP
E04
“DC DETECT”
DC appears in SP terminal by
defect of AMP IC and MOS-
FET.
defect of AMP IC and MOS-
FET.
E05
“THERMISTOR”
Unusual heat up of MOSFET by
improper assembly of heat sink,
destruction of MOSFET etc.
improper assembly of heat sink,
destruction of MOSFET etc.
E06
“FAN BLOCK”
Defect of DC FAN and DC FAN
driver circuit
driver circuit
To release from this mode:
Press [] button and [‒ /
Press [] button and [‒ /
] (SHAKE5) / [‒/PRESET‒]
(SHAKE6D) button simultaneously again or unplug & re-plug in
the power cord.
the power cord.
If speaker does not have output even if the set status is not in
PROTECT mode, the following defect might be possible:
PROTECT mode, the following defect might be possible:
Defects
Possible cause
RESET defect
Reset signal status from micom is not ‘H’.
If the PROTECT mode is “POWER SUPPLY”, there is possibility
of unusual power supply of any of the AMP IC or Pre-amplifi er.
of unusual power supply of any of the AMP IC or Pre-amplifi er.
HCD-SHAKE5/SHAKE6D
15
[DVD COLOR SYSTEM MODE] (SHAKE6D)
• This mode let you change the color system of the video output
• This mode let you change the color system of the video output
from PAL to NTSC or vice-versa.
Procedure:
1. Press the [\/1] button to turn on the system.
2. Press the [DVD/CD] button.
3. Press the [ENTER] button and [LED COLOR] button
2. Press the [DVD/CD] button.
3. Press the [ENTER] button and [LED COLOR] button
simultaneously and hold for 3 seconds.
4. The message “COLOR PAL” or “COLOR NTSC” appears on
the fl uorescent indicator tube.
•
To release from DVD Color System Mode
1. Once the color system has been selected, the mode is fi xed
there after. If you wish to change the mode again, perform the
above item 3 again.
above item 3 again.
[DVD SERVICE MODE] (SHAKE6D)
• This mode let you make diagnosis and adjustment easily by
• This mode let you make diagnosis and adjustment easily by
using the remote commander and the TV. The instructions,
diagnostic results, etc. are given on the on-screen display.
diagnostic results, etc. are given on the on-screen display.
•
TEST DISC LIST
Be sure to use the DVD disc that matches the signal standards
of your region.
of your region.
• CD
YEDS-18
(Part No.: 3-702-101-01)
PATD-012
(Part No.: 4-225-203-01)
• DVD SL (Single Layer)
NTSC : HLX-503 (Part No.: J-6090-069-A)
HLX-504 (Part No.: J-6090-088-A)
PAL :
HLX-506 (Part No.: J-6090-077-A)
• DVD DL (Double Layer)
NTSC : HLX-501 (Part No.: J-6090-071-A)
HLX-505 (Part No.: J-6090-089-A)
PAL :
HLX-507 (Part No.: J-6090-078-A)
•
Procedure to enter DVD Service Mode:
1. Press the [\/1] button to turn on the system.
2. Press the [DVD/CD] button.
3. Press the [ENTER] button and [+/PRESET+] button
2. Press the [DVD/CD] button.
3. Press the [ENTER] button and [+/PRESET+] button
simultaneously and hold 3 seconds.
4. The message “SERVICE IN” appears on the fl uorescent
indicator tube and the Top Menu of Remocon Diagnosis
Menu appears on the on-screen display on the TV.
Menu appears on the on-screen display on the TV.
The display of the “Model Name” of the “Remocon Diagnosis
Menu” change with the model and the destination. Refer to
below on the model name.
Menu” change with the model and the destination. Refer to
below on the model name.
STOMJRD : SHAKE-6D
*1: Changes depending on destination
5. To execute each function, press its number by using numeric
button on the remote commander.
6. To release from this mode, press the [\/1] button to turn off
the system.
•
Execute IOP Measurement
In order to execute IOP measurement, the following standard
procedures must be followed.
procedures must be followed.
1. From the Top Menu of Remocon Diagnosis Menu, select
“2. Drive Manual Operation” by pressing the [2] button on
the remote commander. The following screen appears on the
on-screen display.
the remote commander. The following screen appears on the
on-screen display.
2. Select “3. Manual Adjustment” by pressing the [3] button on
the remote commander. The following screen appears on the
on-screen display.
on-screen display.
3. Select “6. Iop:” by pressing the [6] button on the remote
commander.
4. Wait until a hexadecimal number appears in the on-screen
display as below:
5. Convert data from hexadecimal to decimal by using
conversion table.
6. Please
fi nd the label on the rear of the BU (Base Unit).
The default IOP value is written in the label.
7. Subtract between these two values.
8. If the remainder is smaller than 93 (decimal), then it is OK.
8. If the remainder is smaller than 93 (decimal), then it is OK.
However if the value is higher than 93, then the BU is defective
and need to be change.
and need to be change.
9. Press the [RETURN] button on the remote commander to
return to previous menu.
10. Press the [0] button on the remote commander to return to the
Top Menu of Remocon Diagnosis Menu.
11. Press the [\/1] button to turn off the system.
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
5. USB Test Mode Setting
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
5. USB Test Mode Setting
Model Name
IF-con
Syscon
IF-con
Syscon
: SHAKE6D_ XX
*1
: Ver. XX.XX (XXXX)
: Ver. X.XXX
: Ver. X.XXX
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Mecha test mode
5. MIRR time Adjust
0. Return to Top Menu
2. Track/Layer Jump
3. Manual Adjustment
4. Mecha test mode
5. MIRR time Adjust
0. Return to Top Menu
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg Boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve (FE) Level:
9. RFL (PI) Level:
0. MIRR Time:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg Boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve (FE) Level:
9. RFL (PI) Level:
0. MIRR Time:
O
o Change Value
RETURN Return to previous menu
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg Boost Adjust:
6. Iop. ED
7. TRV. Level:
8. S curve (FE) Level:
9. RFL (PI) Level:
0. MIRR Time:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg Boost Adjust:
6. Iop. ED
7. TRV. Level:
8. S curve (FE) Level:
9. RFL (PI) Level:
0. MIRR Time:
O
o Change Value
RETURN Return to previous menu
HCD-SHAKE5/SHAKE6D
16
•
Check Emergency History
To check the emergency history, please follow the following
procedure.
procedure.
1. From the Top Menu of Remocon Diagnosis Menu, select
“3. Emergency History” by pressing the [3] button on the
remote commander. The following screen appears on the on-
screen display.
remote commander. The following screen appears on the on-
screen display.
2. You can check the total time when the laser is turned on
during playback of DVD and CD from the above menu. The
maximum time, which can be displayed are 999h 59min.
maximum time, which can be displayed are 999h 59min.
3. You can check the error code of latest 10 emergency history
from the above menu. To view the previous or next page of
emergency history, press the [.] button or [>] button
on the remote commander. The error code consists of
emergency history, press the [.] button or [>] button
on the remote commander. The error code consists of
•
Error Code
The meaning of error code is as below:
01: Communication error (No reply from syscon)
02: Syscon hung up
03: Power OFF request when syscon hung up
19: Thermal shutdown
24: MoveSledHome error
25: Mechanical move error (5 Changer)
26: Mechanical move stack error
30: DC motor adjustment error
31: DPD offset adjustment error
32: TE balance adjustment error
33: TE sensor adjustment error
34: TE loop gain adjustment error
35: FE loop gain adjustment error
36: Bad jitter after adjustment
40: Focus NG
42: Focus layer jump NG
51: Spindle stop error
52: Open kick spindle error
60: Focus on error
61: Seek fail error
62: Read Q data/ID error
70: Lead in data read fail
71: TOC read time out (CD)
80: Can’t buffering
81: Unknown media type
01: Communication error (No reply from syscon)
02: Syscon hung up
03: Power OFF request when syscon hung up
19: Thermal shutdown
24: MoveSledHome error
25: Mechanical move error (5 Changer)
26: Mechanical move stack error
30: DC motor adjustment error
31: DPD offset adjustment error
32: TE balance adjustment error
33: TE sensor adjustment error
34: TE loop gain adjustment error
35: FE loop gain adjustment error
36: Bad jitter after adjustment
40: Focus NG
42: Focus layer jump NG
51: Spindle stop error
52: Open kick spindle error
60: Focus on error
61: Seek fail error
62: Read Q data/ID error
70: Lead in data read fail
71: TOC read time out (CD)
80: Can’t buffering
81: Unknown media type
Emg. History Check
1. 01 05 04 04
Laser Hours
CD
999h
59min
DVD
999h
59min
00 92 46 00
00 00 00 00
00 00 23 45
2. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
Next Next Page
Prev Prev Page
O Return to Top Menu
•
Parameter of error code
This is the detail of error code.
•
Time of error code
This is the laser time when an error occurred.
To clear the Laser Hours
Press the [
DISPLAY] button and then press the [CLEAR]
button. The data for both CD and DVD data are reset.
To clear the Emergency History
Press the [DVD TOP MENU] button and then press the [CLEAR]
button.
The error code for all emergency history would be reset.
button.
The error code for all emergency history would be reset.
To clear the Initialize Setup Data
Press the [DVD/TUNER MENU] button and then press the
[CLEAR] button on the remote commander.
[CLEAR] button on the remote commander.
Example of Error code
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
Example of Error code
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
Example of Error code
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
Emg. History Check
1. 01 05 04 04
Laser Hours
CD
0h
0min
DVD
0h
0min
00 92 46 00
00 00 00 00
00 00 23 45
2. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
Next Next Page
Prev Prev Page
O Return to Top Menu
Emg. History Check
1. 00 00 00 00
Laser Hours
CD
999h
59min
DVD
999h
59min
00 00 00 00
00 00 00 00
00 00 00 00
2. 00 00 00 00
00 00 00 00
00 00 00 00
00 00 00 00
Next Next Page
Prev Prev Page
O Return to Top Menu
Emg. History Check
Initialize setup data...
Laser Hours
CD
999h
59min
DVD
999h
59min
Next Next Page
Prev Prev Page
O Return to Top Menu
Click on the first or last page to see other HCD-SHAKE5 / HCD-SHAKE6D (serv.man2) service manuals if exist.