— 13 —
TUNER SECTION
0 dB=1µV
AM Tuning Voltage  Adjustment
Procedure:
1.
Set the reception frequency of the unit to 530 kHz.
2.
Adjust L105 for 1.2 ± 0.05 V reading on the DC voltmeter.
3.
Set the reception frequency of the unit to 1,710 kHz.
4.
Confirm that the voltage reading on the DC voltmeter is within
8.0 ± 0.5 V.
Adjustment Location:  MAIN board (See page 14)
AM Tracking  Adjustment
Procedure:
1.
Tune the set to 600 kHz.
2.
Set the output of AM RF SSG so that the input level of the set
will become 60 dB (µV/m).
3.
Adjust L104 so that when the waveform on the oscilloscope is
maximum, no noise appears.
4.
Tune the set to 1,400 kHz.
Main board
TP1
G
VT
DC voltmeter
+
AM RF  SSG
loop antenna
set
loop antenna
(Supplied accessories)
60 cm
AM ANTENNA
terminal (TM1)
30% amplitude
modulation by
400 Hz signal
Field strength dB (
µ
V/m) =SSG output level dB (
µ
V/m) –26 dB.
5.
Adjust TC102 so that when the waveform on the oscilloscope
is maximum, no noise appears.
• Repeat the procedures in each adjustment several times, and the
tracking adjustment should be finally done by the trimmer
capacitors.
Adjustment Location: MAIN board (See page 14)
— 14 —
FM Tuned Level Adjustment
Procedure:
1.
Supply a 28 dB 98 MHz signal from the ANTENNA terminal.
2.
Tune the set to 98 MHz.
3.
Adjust SFR101 to the point (moment) when the TUNED
indicator will change from going off to going on.
Adjustment Location: MAIN board
Adjustment Location
[MAIN BOARD] — Component side —
FM RF SSG
75 
 coaxial
Carrier frequency : 98 MHz
Modulation           : AUDIO 1 kHz, 75 kHz
                              deviation (100%)
Output level          : 28 dB  (at 75 W open)
FM ANTENNA terminal
(JK101)
set
L104
TC102
TP1
SFR101
L105
FM Tuned Level
AM Tuning Voltage
AM Tracking
JK101
— 15 —
CD SECTION
Note:
1.
CD Block is basically constructed to operate without
adjustment. Therefore, check each item in order given.
2.
Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3.
Use an oscilloscope with more than 10M
 impedance.
4.
Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the
following checks.
5.
Adjust the focus bias adjustment when optical block is replaced.
RF Level Check
Procedure :
1.
Connect oscilloscope to test point TP (RF) on CD DECODER
board.
2.
Turned Power switch on.
3.
Put disc (YEDS-18) in and playback.
4.
Confirm that oscilloscope waveform is clear and check RF
signal level is correct or not.
Note: Clear RF signal waveform means that the shape “
” can be
clearly distinguished at the center of the waveform.
Adjustment Location:
[CD DECODER BOARD] — Component side —
CD DECODER
board
oscilloscope
TP (RF)
TP (VC)
VOLT/DIV: 200 mV
TIME/DIV: 500 nS
level: 1.0         Vp-p
+0.3
–0.2
IC702
IC701
J778
J789
TP (VC)
TP
(RF)
CN701
— 16 —
SECTION 6
DIAGRAMS
6-1. CIRCUIT BOARDS LOCATION
CD DECORD board
FRONT board
MAIN board
SW (A) board
SW (B) board
SW (C) board
SW (D) board
MOTOR board
H/P SUPPLY board
AC SUPPLY board
VR SWITCH board
TR board
SENSOR board
MOTOR (6P) (S) board
Page of 50
Display

Click on the first or last page to see other HCD-RXD2 / MHC-RXD2 service manuals if exist.