21
SECTION  3
TEST  MODE
[COLD  RESET]
The cold reset clears all data including preset data stored in the 
RAM to initial conditions. Execute this mode when returning the 
set to the customer.
Procedure:
1.  Press the [
?/1
] button to turn the power ON.
2.  Press three buttons of [
?/1
], [PRESET EQ] and [DISC 3] si-
multaneously.
3.  The message “RESET” is displayed on the LCD display mo-
mentarily, then becomes standby states.
[TUNING  STEP  CHANGE] (E3, PH, SP models)
A step of AM tuning interval can be changed over between 9 kHz 
and 10 kHz.
Procedure:
1.  Press the [
?/1
] button to turn the power on.
2.  Press the [TUNER/BAND] button to select “AM”.
3.  Press the [
?/1
] button to turn the power off. When the set is 
in the ECO mode at that time, any later operations are invalid.  
These operations should be performed either in the DEMO 
mode or while the clock is displayed.
4.  Press the [
?/1
] button while pressing the [
y
 
M
/TUNING +] 
button.
5.  The message “AM 9K STEP” or “AM 10K STEP” is displayed 
on the LCD display, and thus the channel step is changed over.
[DVD  SHIP  MODE]
This mode moves the optical pick-up to the position durable to 
vibration. Use this mode when returning the set to the customer 
after repair.
Procedure:
1.  Ensure that no disc is placed in the DVD tray.
2.  Press the [
?/1
] button to turn the power on.
3.  Press the [DVD] button to select “DVD”.
4.  Press two buttons of [
N
] and [
?/1
] simultaneously.
5.  The message “LOCK” is displayed on the LCD display, and 
the DVD ship mode is set.
6.  To release from the mode, disconnect the AC plug to turn the 
power off.
[DVD  SHIP  MODE  &  COLD  RESET]
This mode is used to perform DVD ship (lock) mode and cold reset 
simultaneously.
Procedure:
1.  Ensure that no disc is placed in the DVD tray.
2.  Press the [
?/1
] button to turn the power on.
3.  Press the [DVD] button to select “DVD”.
4.  Press three buttons of [
x
], [ENTER] and [
?/1
] simultane-
ously.
5.  The message “RESET” is displayed on the LCD display mo-
mentarily, then becomes standby states.
6.  To release from the mode, disconnect the AC plug to turn the 
power off.
[CHANGE-OVER  FUNCTION  OF  SAT/VIDEO]
This mode is used to enable function of external input to change 
over between SAT and VIDEO.
Procedure:
1.  Press the [
?/1
] button to turn the power on.
2.  Press two buttons of [VIDEO/SAT] and [
?/1
] simultaneously.
3.  The message “SAT” or “VIDEO” is displayed on the LCD dis-
play, and the function of external input is changed over.
[DVD  COLOR  SYSTEM  CHANGE]
(E3, PH, SP, EA models)
Color system change to video signal format (NTSC/PAL).
Procedure:
1.  Press the [
?/1
] button to turn the power on.
2.  Press the [FUNCTION] button to set the function “DVD”.
3.  Press the [
?/1
] button to turn the power off. When the set is 
in the ECO mode at that time, any later operations are invalid.  
These operations should be performed either in the DEMO 
mode or while the clock is displayed.
4.  Press the [
?/1
] button while pressing the [
X
] button.
5.  The display of LCD display changes to “COLOR PAL” or 
“COLOR NTSC”.
[DVD  TRAY  LOCK  MODE]
This mode is used to unable to take sample disc out of tray in the 
shop.
Procedure:
1.  Press the [
?/1
] button to turn the power on.
2.  Press the [DVD] button to select “DVD”.
3.  Set disc on the DVD tray, press two buttons of [
x
] and [
Z
] for 
5 seconds.
4.  The message “LOCKED” is displayed on the LCD display and 
the DVD tray is locked. (Even if pressing the [
Z
] button, the 
message “LOCKED” is displayed on the LCD display and the 
DVD tray is locked)
5.  To release from this mode, press two buttons of [
x
] and [
Z
for 5 seconds.
6.  The message “UNLOCKED” is displayed on the LCD display 
and the DVD tray is unlocked.
HCD-RV222D/RV222DL/RV333D/RV333DL/RV555D
22
[PANEL  TEST  MODE]
This mode is used to check the LCD display, LEDs, keys, [MAS-
TER VOLUME] jog, model, destination and software version.
Procedure:
1.  Press [
?/1
] button to turn on the system.
2.  Press [
x
] button, [ENTER] button and [DISPLAY] button si-
multaneously.
3.  All LEDs and segments in LCD display are lighted up. All 
LEDs are lighted.
4.  Pressing the [DISC 1] button gets the date/version and DVD 
Lib version shown on the LCD display.
G 0 1 0 0 A 0 3 0 3
Press [DISC 1] button.
Release date
Version of the MC
G 0 0 4 4 A 0 3 0 2
Press [DISC 1] button.
Release date
Version of the DVD-lib
included in the MC
5.  Pressing the [DISC 2] button gets the destination shown on the 
LCD display.
6.  Pressing the [DISC 3] button causes the KEY TEST mode to 
be entered with the Key Test display appearing on the LCD 
display.
    
K E Y     0     0     0
KEY 1
KEY 2
KEY 3
Key Test display
KEY 1
KEY 2
KEY 3
Count
Button name
Count
Button name
Count
Button name
0
0
0
1
?/1
1
PRESET EQ
1
N
2
DISPLAY
2
ECHO
2
X
3
DVD
3
TUNING –
3
Z
OPEN/CLOSE
4
TAPE A/B
4
BUSWOOFER
(RV333D only)
4
DISC SKIP/
EX-CHANGE
5
TUNER/BAND
5
y
 M
TUNING +
5
DISC 1
6
VIDEO/SAT
6
REC TO TAPE
6
DISC 2
7
./
PRESET –
7
x
7
DISC 3
8
>/
PRESET +
8
GROOVE
8
ENTER
7.  To release from this mode, press three buttons in the same 
manner as step 2, or disconnect the power cord.
[COMMON  TEST  MODE]
This mode is used to check operations of the respective sections of 
Amplifi er and VACS.
Procedure:
1.  Press the [
?/1
] button to turn on the system.
2.  Press [
Z
] button, [DISPLAY] button and [PRESET EQ] but-
ton simultaneously. The message “VACS0” appears on the 
LCD display.
•  Releasing from the mode:
3.  Press the [
?/1
] button. “COLD RESET” is executed and then 
the power is tuned off.
•  Switching the EQ mode of Amplifi er:
4.  Each time the [PRESET EQ] button is pressed, the EQ mode is 
switched as follows:
ALL  EQ  MIN
ALL  EQ  MAX
ALL  EQ  FL
•  Changing the GAIN of Amplifi er:
5.  Pressing the [ECHO] button causes the LCD display to show 
the message “VOLUME MIN” and the GAIN of Amplifi er to 
be set to the minimum.
6.  Pressing the [GROOVE] button causes the LCD display to 
show the message “VOLUME MAX” and the GAIN of Am-
plifi er to be set to the maximum.
•  Setting the VACS to ON or OFF:
7  Each time the [REC TO TAPE] button is pressed, the message 
on the LCD display changes between “VACS ON” and “VACS 
OFF” and the VACS is set to ON or OFF.
[VACS  DISPLAY]
This mode is used to check the VACS level.
Procedure:
1.  Press [
?/1
] button to turn on the system.
2.  Press [DISPLAY] button, [PRESET EQ] button and [ENTER] 
button simultaneously.
3.  The message “V$  %  #” appears on the LCD display. 
 
“$” is the Conventional VACS level.
 
“%” is the present value of the input.
 
“#” is the peak value of the input.
HCD-RV222D/RV222DL/RV333D/RV333DL/RV555D
23
[DVD  SERVICE  MODE]
1.  GENERAL  DESCRIPTION
The IOP measurement allows you to make diagnosis and adjust-
ment simply by using the remote commander and monitor TV. The 
instructions, diagnosis results, etc. are given on the on-screen dis-
play (OSD).
Be sure to execute the IOP measurement when a BU (Base Unit) 
is replaced.
2.  HOW  TO  ENTER  TEST  MODE
While pressing the [
x
] and [
Z
] buttons simultaneously, turn 
[VOLUME] control in the direction of (+) with the DVD player 
in power on.
The Test Mode starts, displayed “SERVICE IN” on this model 
display then the menu shown below will be displayed on the TV 
screen.
*  The display of the “Model Name” of the “Remocon Diagnosis 
Menu” change with the model and the destination. Refer to 
below on the model name.
 
RV222D/RV222DL : RV0D
 
RV333D/RV333DL : RV2DS
 
RV555D : RV1D
The menu above is the Remocon Diagnosis Menu screen which 
consists of fi ve main functions. At the bottom of the menu screen, 
the model name and IF-con version. To exit from the Test Mode, 
press the [
?/1
] button on the remote commander.
3.  EXECUTING  IOP  MEASUREMENT
In order to execute IOP measurement, the following standard pro-
cedures must be followed.
(1)  In power on, while pressing the [
x
] and [
Z
] buttons simulta-
neously, turn the [VOLUME] control in the direction of (+).
(2)  Select “2. Drive Manual Operation” by pressing the [2] button 
on the remote commander. The screen will appear as shown.
(3)  Select “3. Manual Adjustment” by pressing the [3] button on 
the remote commander. The screen will appear as shown.
(4)  Select “6. IOP” by pressing the [6] button on the remote com-
mander.
(5)  Wait until a hexadecimal number appear.
(6)  Convert each data from hexadecimal to decimal using conver-
sion table.
(7) Please fi nd the label on the rear of the BU (Base Unit).
 
The default IOP value is written in the label.
(8)  Subtract between these two values.
(9)  If the remainder is smaller than 93 (decimal), then it is OK. 
However if the value is higher than 93, then the BU is defec-
tive and need to be change.
(10) Press the [RETURN] button on the remote commander to re-
turn back to previous menu.
(11) Press the [0] button on the remote commander to return to Top 
Menu.
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
Model Name
IF-con
: Ver. XX.XX (XXXX)
Syscon
: Ver. X.XXX
: RV2DS_XX
*
1
*1: Changes depending on destination 
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
Model Name
IF-con
: Ver. XX.XX (XXXX)
Syscon
: Ver. X.XXX
: RV2DS_XX
*
1
*1: Changes depending on destination 
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
5. MIRR time adjust
0. Return to Top Menu
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
O o  Change Value
[RETURN] Return to previous menu
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop. 4C:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
[RETURN] Return to previous menu
O o  Change Value
Ver. 1.3
HCD-RV222D/RV222DL/RV333D/RV333DL/RV555D
24
 
52:   Open kick spindle error
 
60:   Focus on error
 
61:   Seek fail error
 
62:   Read Q data/ID error
 
70:   Lead in data read fail
 
71:  TOC read time out (CD)
 
80:   Can’t buffering
 
81:   Unknown media type
4-1.  Clear the Laser Hour
Press [  DISPLAY] button and then press [CLEAR] button on the 
remote commander. The data for both CD and DVD data are reset.
4-2.  Clear the Emergency History
Press [DVD TOP MENU]  button and then press [CLEAR] button 
on the remote commander. The error code for all emergency his-
tory would be reset.
4-3.  Clear the Initialize Setup Data
Press [DVD MENU] button and then press [CLEAR] button on the 
remote commander.
4.  EMERGENCY  HISTORY
To check the emergency history, please follow the following pro-
cedure.
(1) From the Top Menu of Remocon Diagnosis Menu, select “3. 
Emergency History Check” by pressing the [3] button on the 
remote commander. The following screen appears on the on-
screen display.
(2)  You can check the total time when the laser is turned on during 
playback of DVD and CD from the above menu. The maxi-
mum time, which can be displayed are 999h 59min.
(3) You can check the error code of latest 10 emergency history 
from the above menu. To view the previous or next page of 
emergency history, press [
.
] or [
>
] button on the remote 
commander. The error code consists of the following three 
blocks. The fi rst block indicates the error code. The second 
block indicates the parameter and the third block indicates the 
time of error code as shown below.
•  Error Code
 
*1 : Error Code
 
*2 : Parameter of error code
 
*3 : Time of error code
 
The meaning of error code is as below:
 
01:   Communication error (No reply from syscon)
 
02:   Syscon hung up
 
03:   Power OFF request when syscon hung up
 
19:   Thermal shutdown
 
24:   MoveSledHome error
 
25:   Mechanical move error (5 Changer)
 
26:  Mechanical move stack error
 
30:   DC motor adjustment error
 
31:   DPD offset adjustment error
 
32:   TE balance adjustment error
 
33:   TE sensor adjustment error
 
34:   TE loop gain adjustment error
 
35:   FE loop gain adjustment error
 
36:   Bad jitter after adjustment
 
40:   Focus NG
 
42:   Focus layer jump NG
 
51:   Spindle stop error
Emg. History Check
01.  01  05  04  04
Laser Hours
CD
999h
59min
DVD
999h
59min
00  92  46  00
00  00  00  00
00  00  23  45
02.  02  02  01  01
00  A9  4B  00
00  00  00  00
00  00  23  45
 
[Next]   Next Page    [Prev]  Prev Page
[O]  Return to Top Menu
Emg. History Check
01.  01  05  04  04
Laser Hours
CD
999h
59min
DVD
999h
59min
00  92  46  00
00  00  00  00
00  00  23  45
02.  02  02  01  01
00  A9  4B  00
00  00  00  00
00  00  23  45
 
[Next]   Next Page    [Prev]  Prev Page
[O]  Return to Top Menu
*
1
*
2
*
3
Emg. History Check
01.  01  05  04  04
Laser Hours
CD
0h
0min
DVD
0h
0min
00  92  46  00
00  00  00  00
00  00  23  45
02.  02  02  01  01
00  A9  4B  00
00  00  00  00
00  00  23  45
 
[Next]   Next Page    [Prev]  Prev Page
[O]  Return to Top Menu
01.  00  00  00  00
Laser Hours
CD
999h
59min
DVD
999h
59min
00  00  00  00
00  00  00  00
00  00  00  00
02.  00  00  00  00
00  00  00  00
00  00  00  00
00  00  00  00
 
[Next]   Next Page    [Prev]  Prev Page
[O]  Return to Top Menu
Emg. History Check
Emg. History Check
initialize setup data...
Laser Hours
CD
999h
59min
DVD
999h
59min
 
[Next]   Next Page    [Prev]  Prev Page
[O]  Return to Top Menu
Page of 102
Display

Click on the first or last page to see other HCD-RV222D / HCD-RV333D / HCD-RV555D / MHC-RV222D / MHC-RV222DL / MHC-RV333D / MHC-RV333DL / MHC-RV555D service manuals if exist.