hcd-rg40-mhc-dx30-mhc-rg40.pdf
Date

Sony HCD-RG40 / MHC-DX30 / MHC-RG40 Service Manual ▷ View online

16
HCD-DX30/RG40
2)  Operation during aging mode
In the aging mode, the program is executed in the following
sequence.
(1)
The disc tray opens and closes.
(2)
The mechanism accesses DISC 2 and makes an attempt to
read TOC.  However, since there are no discs, a message
“CD2 NO DISC” appears.
(3)
The mechanism accesses DISC 3 and a message “CD3 NO
DISC” appears.
(4)
The disc tray turns to select a disc1.
(5)
A disc is chucked.
(6)
TOC of disc is read.
(7)
The pickup accesses to the track 1, and  playing 2 seconds.
(8)
The pickup accesses to the last track, and playing 2 seconds.
(9)
Every time when an aging operation of step 1 to step 8 is
complete, the display “AGING[*][*][*][*]” value increases
as the number of aging operations is counted up.
(10) Returns to step 1.
3. Aging Mode in Tape Deck section
1) Display state
• No error occurs
Display action now
• Error occurred
Display action last time
2)  Operation during aging mode
In the aging mode, the program is executed in the following
sequence.
(1) Rewind is executed up to the top of tape A and B.
(2) A tape on FWD side is played for 2 minutes.
(3) FF is executed up to either made for 20 second or the end of
tape.
(4) A tape is reversed, and the tape on REV side is played for 2
minutes.
The tape on the REV side is played in both A and B.
(5) Rewind is executed up to the top of tape.
(6) Returns to step 2, and repeat steps from 2 to 5.
[Function Change Mode]
* elect either VIDEO or MD of the external FUNCTION input.
Procedure:
1.
Turn on the power.
2.
Press the two buttons  MD (VIDEO)  and  ?/1  at the same
time.
The main power is turned on and the other function of the
previous function is selected and displayed.  “MD” or
“VIDEO”.
NO. Display action
Action contents
Final timing
1
TAPE A AG-6
Rewind the TAPE A
The top of tape
TAPE B AG-1
Rewind the TAPE B
2
TAPE A AG-2
FWD play the TAPE A
2 minutes playing
3
TAPE A AG-3
F.F. the TAPE A
20 second FF or the end
of tape
4
TAPE A AG-4
REV play the TAPE A
2 minutes playing
5
TAPE A AG-5
Rewind the TAPE A
The top of tape
6
TAPE B AG-2
FWD play the TAPE B
2 minutes playing
7
TAPE B AG-3
F.F. the TAPE B
20 second FF or the end
of tape
8
TAPE B AG-4
REV play the TAPE B
2 minutes playing
9
TAPE B AG-5
Rewind the TAPE B
The top of tape
17
HCD-DX30/RG40
SECTION 5
ELECTRICAL ADJUSTMENTS
FM Tuned Level Adjustment
Procedure:
1.
Supply a 98 MHz signal at 28 dB from the ANTENNA terminal.
2.
Tune the set to 98 MHz.
3.
Adjust RV101 to the point (moment) when the TUNED
indicator will change from going off to going on.
Adjustment Location: MAIN board
Null Adjustment
Procedure:
1.
Supply a 98 MHz signal at 60 dB from the ANTENNA terminal.
2.
Tune the set to 98 MHz.
3.
Measure voltage between pin 21 and pin 23 of IC 101.  Adjust
T101 ubtil the voltage becomes 0 V.
Adjustment Location: MAIN board
Adjustment Location
[MAIN BOARD]   Component side
FM RF Signalgenerator
75 
 coaxial
Carrier frequency : 98 MHz
Modulation           : AUDIO 1 kHz, 75 kHz
                              deviation (100%)
Output level          : 28 dB  (at 75 
 open)
FM ANTENNA terminal
(TM101)
set
FM RF Signalgenerator
75 
 coaxial
Carrier frequency : 98 MHz
Modulation           : AUDIO 1 kHz, 75 kHz
                              deviation (100%)
Output level          : 60 dB  (at 75 
 open)
FM ANTENNA terminal
(TM101)
set
CD SECTION
Note :
1. CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.
2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M
Ω impedance.
4. Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the
following checks.
S-Curve Check
Procedure :
1. Connect oscilloscope to TP (FEO).
2. Connect between TP (FEI) and TP (VC) by lead wire.
3. Connect between TP (AGCCON) and TP (D GND) by lead wire.
4. Turn Power switch on.
5. Load a disc (YEDS-18) and actuate the focus search. (In
consequence of open and close the disc tray, actuate the focus
search)
6. Confirm that the oscilloscope waveform (S-curve) is
symmetrical between A and B. And confirm peak to peak level
within 4 
±1 Vp-p.
7. After check, remove the lead wire connected in step 2 and 3.
Note :
• Try to measure several times to make sure than the ratio
of A : B or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
RF Level Check
Procedure :
1. Connect oscilloscope to TP (RF).
2. Connect between TP (AGCCON) and TP (D GND) by lead wire.
3. Turned Power switch on.
4. Load a disc (YEDS-18) and playback.
5. Confirm that oscilloscope waveform is clear and check RF signal
level is correct or not.
6. After check, remove the lead wire connected in step 2.
BD board
Oscilloscope
TP(FEO)
TP(VC)
symmetry
S-curve waveform
within 4 
±
1Vp-p
A
B
TP(RF)
TP(VC)
BD board
oscilloscope
T101
RV661
RV101
IFT101
T102
RV661:TAPE SPEED
T101:NULL
RV101:FM TUNED LEVEL
18
HCD-DX30/RG40
Note :
Clear RF signal waveform means that the shape “ 
◊ ” can be clearly
distinguished at the center of the waveform.
E-F Balance (1 Track jump) Check
Procedure :
1. Connect oscilloscope to TP (TEO) and TP (VC).
2. Turned Power switch on.
3. Load a disc (YEDS-18) and playback the number five track.
4. Press the  gG  button. (Becomes the 1 track jump mode.)
5. Confirm that the level B and A (DC voltage) on the oscilloscope
waveform.
6. After check, remove the lead wire connected in step 1.
RF PLL Free-run Frequency Check
Procedure :
1. Connect frequency counter to test point (XPCK) with lead wire.
2. Turned Power switch on.
3. Put the disc (YEDS-18) in to play the number five track.
Confirm that reading on frequency counter is 4.3218MHz.
RF signal waveform
VOLT/DIV : 200mV
TIME/DIV : 500ns
level : 1.45 
±
 0.3Vp-p
TP(TEO)
TP(VC)
BD board
oscilloscope
level=1.3
±
0.6Vp-p
symmetry
A (DC voltage)
center of
waveform
B
0V
1 track jump waveform
Specified level: –– 
× 100=less than ±22%
B
A
BD board
TP (XPCK)
frequency counter
TP
(XPCK)
TP
(TEO)
TP
(FEO)
TP
(FEI)
TP
(RF)
TP
(VC)
TP
(DGND)
TP
(AGCCON)
1
12
24
1
20
21
40
60
80
41
61
IC101
IC103
Adjustment Location:
[BD BOARD] (Conductor Side)
19
HCD-DX30/RG40
SECTION 6
DIAGRAMS
Note on Schematic Diagram:
• All capacitors are in 
µ
F unless otherwise noted.  pF: 
µµ
F
50 WV or less are not indicated except for electrolytics
and tantalums.
• All resistors are in 
 and 
1
/
4
 
W or less unless otherwise
specified.
¢
: internal component.
C
: panel designation.
Note on Printed Wiring Boards:
• X
: parts extracted from the component side.
• b
: Pattern from the side which enables seeing.
• Indication of transistor.
Note:
The components identi-
fied by mark 
!
 or dotted
line with mark 
!
 are criti-
cal for safety.
Replace only with part
number specified.
Note:
Les composants identifiés par
une marque 
!
 sont critiques
pour la sécurité.
Ne les remplacer que par une
piéce portant le numéro
spécifié.
A
: B+ Line.
B
: B– Line.
H
: adjustment for repair.
• Voltages and waveforms are dc with respect to ground
under no-signal (detuned) conditions.
• Voltages are taken with a VOM (Input impedance 10 M
).
Voltage variations may be noted due to normal produc-
tion tolerances.
no mark : FM
(
) : CD
[
] : TAPE
• Waveforms are taken with a oscilloscope.
Voltage variations may be noted due to normal produc-
tion tolerances.
• Circled numbers refer to waveforms.
• Signal path.
F
: FM
f
: AM
E
: PB (DECK A)
d
: PB (DECK B)
G
: REC (DECK B)
J
: CD
c
: digital out
• Abbreviation
CND : Canadian model
AUS
: Australian model
SP
: Singapore model
KR
: Korea model
MX
: Mexican model
AR
: Argentina model
TH
: Thai model
THIS NOTE IS COMMON FOR PRINTED WIRING BOARDS AND SCHEMATIC DIAGRAMS.
(In addition to this, the necessary note is printed in each block.)
C
B
These are omitted.
E
Q
B
These are omitted.
C
E
Q
• Abbreviation
CND : Canadian model
AUS
: Australian model
SP
: Singapore model
KR
: Korea model
MX
: Mexican model
AR
: Argentina model
TH