— 10 —
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw so
that outputs match within 1 dB of peak.
output
level
3. Mode: Playback
Tape Speed Adjustment (Deck A)
Note: Start the Tape Speed adjustment as below after setting the test
mode.
The tape speed can be changed with the  HIGH SPEED
DUBBING   button during the test mode.
Method :
1. Turn the power switch on.
2. Press the  DISPLAY/DEMO  button,  FILE 1  button and    TUNER/
BAND   button simultaneously.
To exit from the test mode, Press the  SYSTEM POWER  button.
Procedure :
Mode: Playback
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
Adjustment Location: Playback Head (Deck A)
Record/Playback/Erase Head (Deck B)
45˚
90˚
135˚
180˚
wrong
good
in phase
R
set
FWD side
REV side
L-CH
peak
screw
position
R-CH
peak
within
1dB
within 1dB
L-CH
peak
R-CH
peak
screw
position
test tape
P-4-A100
(10kHz, –10dB)
main board
CN403
Pin 
3
 (L-CH)
oscilloscope
Pin 
2
 (GND)
L
Pin 
1
 (R-CH)
Waveform of oscilloscope
Adjustment screw
+
main board
CN403 Pin 
3
 (L-CH)
Pin 
1
 (R-CH)
set
test tape WS-48B
(3kHz, 0dB)
frequency counter
1. Insert the WS-48B into the deck A to playback.
2. Press the  HIGH SPEED DUBBING  button. Then at HIGH
SPEED mode.
3. Adjust the RV652 on the AUDIO board so that the frequency
counter reading becomes 6,000 ± 30 Hz.
4. Press the  HIGH SPEED DUBBING  button again to be set the
NORMAL SPEED mode.
5. Set to the playback mode.
6. Adjust the RV651 on the AUDIO board so that the frequency
counter reading becomes 3,000 ± 15 Hz.
Frequency difference between deck A and deck B the beginning
of the tape should be within ± 1.5%.
Adjustment Location: AUDIO board
Playback Level Adjustment (Deck A,  Deck B)
Procedure:
Mode: Playback
set
test tape P-4-L300
(315Hz, 0dB)
main board
CN403 Pin 
3
 (L-CH)
Pin 
1
 (R-CH)
level meter
Deck A is RV311 (L-CH) and RV411 (R-CH), deck B is RV301
(L-CH) and RV401 (R-CH)
so that adjustment within the following adjustment level.
Adjustment level:
CN403 playback level: 301.5 to 338.3 mV (–8.2 to –7.2 dB)
level difference between the channels: within ± 0.5 dB
Adjustment Location: AUDIO board
— 11 —
Record Bias Adjustment  (Deck B)
Procedure:
Reference)
When set to the test mode performed in 
Tape Speed Adjustment
,
when the tape is rewound after recording, the “REC memory mode”
which rewinds only the recorded portion and stops is set.
This “REC memory mode” is convenient for performing this adjust-
ment.
1. Press  FUNCTION  button to select VIDEO.
2. Mode: record
Record Level Adjustment  (Deck B)
Procedure:
Reference)
When set to the test mode performed in 
Tape Speed Adjustment
,
when the tape is rewound after recording, the “REC memory mode”
which rewinds only the recorded portion and stops is set.
This “REC memory mode” is convenient for performing this
adjustment.
1. Press  FUNCTION  button to select VIDEO.
2. Mode: record
set
VIDEO (AUDIO) IN
1) 315Hz
2) 10kHz
} 50 mV (–23.8 dB)
AF OSC
attenuator
600 
blank tape
CS-123
3. Mode: Playback
4. Confirm playback the signal recorded in step 2 become adjust-
ment level as follows.
If these levels do not adjustment level, adjust the RV341 (L-CH)
and RV441 (R-CH) on the AUDIO board to repeat steps 2 and 3.
Adjustment level: The playback output of 10 kHz level difference
against 315 Hz reference should be ± 0.5 dB.
Adjustment Location: AUDIO board
recorded
position
level meter
VIDEO (AUDIO) IN
315 Hz 50 mV (–23.8 dB)
set
blank tape
CS-123
600 
attenuator
AF OSC
3. Mode: Playback
level meter
set
main board
CN403 Pin 
3
 (L-CH)
Pin 
1
 (R-CH)
recorded
position
4. Confirm playback the signal recorded in step 2 become adjust-
ment level as follows.
If these levels do not adjustment level, adjust the RV301 (L-CH)
and RV351 (R-CH) on the main board to repeat steps 2 and 3.
Adjustment level:
CN403 PB level: 47.2 to 53.0 mV (–24.3 to –23.3 dB)
Adjustment Location: MAIN board
Adjustment Location
[AUDIO BOARD] 
(Conductor Side)
[MAIN BOARD] (Component Side)
main board
CN403 Pin 
3
 (L-CH)
Pin 
1
 (R-CH)
set
1  3
CN403
RV351
IC401
RV301
RV351
Record Level Adjustment
(R CH)
RV301
Record Level Adjustment
(L CH)
RV341(Lch),RV441(Rch)
Record Bias
RV301
RV401
RV441 RV341
RV301(Lch),RV401(Rch)
Playback Level (Deck B)
RV651 (Normal Speed)
RV652 (High Speed)
Tape Speed
RV652
RV651
RV311
RV411
RV311(Lch),RV411(Rch)
Playback Level (Deck A)
— 12 —
TUNER SECTION
0dB=1µV
Note: 1. As a front-end (FE1) is difficult to repair if faulty, replace
it with new one.
AM Tuned Level Adjustment
Note: FM Tuned Level adjustment should be performed after this
AM Tuned Level Adjustment.
Setting:
Band: MW
loop antenna
Field strength dB (µV/m) = SSG output level dB (µV/m) –26dB.
Procedure:
1. Set the output of SSG so that the input level of the set becomes 55
dB.
2. Tune the set to 999 kHz or 1,050 kHz.
3. Adjust RV42 to the point (moment) when the TUNED  indicator
will change from going off to going on.
Adjustment Location: TCB board
FM Tuned Level Adjustment
Note: This adjustment should be performed after the AM Tuned
Level Adjustment.
Setting:
Band: FM
AM RF SSG
30% amplitude
modulation by
400Hz signal
60cm
AM antenna
terminal (TM1)
loop antenna
(Supplied accessories)
Modulation: 999 kHz (at 9 kHz step)
1,050 kHz (at 10 kHz step)
set
75 
 coaxial
set
Carrier frequency: 98MHz
Modulation:
AUDIO 1kHz, 75kHz
deviation (100%)
Output level:
25dB (at 75 
 open)
FM RF SSG
FM ANTENNA terminal
(TM1)
Procedure:
1. Supply a 25 dB 98 MHz signal from the ANTENNA terminal.
2. Tune the set to 98 MHz.
3. Adjust RV41 to the point (moment) when the TUNED indicator
will change from going off to going on.
Adjustment Location
[TCB BOARD] 
(Component Side)
RV42
AM Tuned
Level
TM1
FE1
RV41
FM  Tuned Level
IC2
— 13 —
CD SECTION
Note:
1. CD Block is basically constructed to operate without adjustment.
Therefore, check each item in order given.
2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M  impedance.
4. Clean the object lens by an applicator with neutral detergent when
the signal level is low than specified value with the following
checks.
5. Adjust the focus bias adjustment when optical block is replaced.
Focus Bias Adjustment
Procedure:
1. Connect oscilloscope to test point TP (RF).
2. Turned Power switch on.
3. Put disc (YEDS-18) in and playback.
4. Adjust RV101 so that the waveform is clear.
(Clear RF signal waveform means that the shape “
” can be clearly
distinguished at the center of the waveform.)
5. After adjustment, check the RF signal level.
• RF signal
VOLT/DIV: 200 mV
TIME/DIV: 500 nS
oscilloscope
BD board
TP (RF)
TP (VC)
level: 1.3 ± 0.3 Vp-p
Procedure :
1. Connect oscilloscope to test point TP (FEO).
2. Connect between test point TP (FOK) and Ground by lead wire.
3. Turn Power switch on.
4. Put disc (YEDS-18) in and turned Power switch on again and
actuate the focus search. (actuate the focus search when disc table
is moving in and out.)
5. Check the oscilloscope waveform (S-curve) is symmetrical be-
tween A and B. And confirm peak to peak level within 2.4 ± 0.7
Vp-p.
S-curve waveform
S Curve Check
6. After check, remove the lead wire connected in step 2.
Note:
 • Try to measure several times to make sure than the ratio of
A : B or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the bright-
ness to obtain best waveform.
RF Level Check
Procedure :
1. Connect oscilloscope to test point TP (RF) on BD board.
2. Turned Power switch on.
3. Put disc (YEDS-18) in and playback.
4. Confirm that oscilloscope waveform is clear and check RF signal
level is correct or not.
Note:
Clear RF signal waveform means that the shape “
” can be
clearly distinguished at the center of the waveform.
RF signal waveform
level: 1.3 ± 0.3 Vp-p
VOLT/DIV: 200 mV
TIME/DIV: 500 nS
A
B
within 2.4 ± 0.7 Vp-p
symmetry
oscilloscope
BD board
oscilloscope
BD board
TP (RF)
TP (VC)
TP (FEO)
TP (VC)