17
SECTION  3
TEST  MODE
COLD  RESET
The cold reset clears all data including preset data stored in the 
memory to initial conditions. Execute this mode when returning 
the set to the customer.
Procedure:
1.  In the standby status, press the [
?
/
1
] button to turn the power 
on.
2.  Press two buttons of [ENTER] and [
?
/
1
] simultaneously.
3.  When “RESET” appears, the set enters.
AUTO  STANDBY  MODE
This mode is used to change the automatic standby function.
With this function, the system enters standby mode automatically 
in about 30 minutes when there is no operation or audio signal 
output. By default, the automatic standby function is turned on.
Procedure:
1.  Press the [
?
/
1
] button to turn the power on.
2.  Press the [
?
/
1
] button for 2 seconds.
3.  The message “AUTO STANDBY” is displayed on the liquid 
crystal element and the automatic standby OFF mode is set.
4.  To turn this function on, press the [
?
/
1
] button again for 2 sec-
onds.
 
The message “AUTO STANDBY” is displayed on the liquid 
crystal element and the automatic standby ON mode is set.
COMMON  TEST  MODE
This mode is used to check operations of amplifi er.
Procedure:
1.  Press the [
?
/
1
] button to turn the power on.
2.  Press two buttons of [ENTER] and [FUNCTION] simultane-
ously.
3.  When the COMMON test mode is activated, “AUDIO IN” is 
displayed on the liquid crystal element and “
c PLAY SLEEP” 
blink on the liquid crystal element.
4.  Each time [EQ] button on the remote commander is pressed, 
the display changes starting “TONE MAX”, “TONE MIN” 
and “TONE FLAT” this order.
5.  Turn the [VOLUME] knob counterclockwise, “VOLUME 
MIN”  is displayed on the liquid crystal element. Turn the 
[VOLUME] knob clockwise, “VOLUME MAX” is displayed 
on the liquid crystal element.
Releasing method:
Press the [
?
/
1
] button to turn off the system.
PANEL  TEST  MODE
This mode is used to check the liquid crystal element, LED, model, 
destination, software version and key.
Procedure:
1.  Press the [
?
/
1
] button to turn the power on.
2.  Press two buttons of [ENTER] and [
x
] simultaneously.
3.  All segments on the liquid crystal element, [STANDBY] LED 
light up. 
4.  Press the [ENTER] button, the model and destination are dis-
played on the liquid crystal element.
5.  Press the [ENTER] button again, MC version is displayed on 
the liquid crystal element.
6.  Each time [ENTER] button is pressed, the display changes 
starting from MC version, GC version, USBL version , USBM 
version, NWA version, NWD version, NWM version, IPL ver-
sion, CD version, CDD version, CDMA version, CDMB ver-
sion, BDA version, BDB version, ST version, TA version and 
TM version this order, and returns to the MC version display.
7. When 
[
x
] button is pressed while the MC version is displayed, 
year, month and day of the software creation is displayed. 
When [
x
] button is pressed again, the display returns to the 
MC version display.
8.  Press the [OPTIONS] button, the key test mode is activated 
and “K 0 V0” is displayed on the liquid crystal element.
9.  Each time a button is pressed, “K” value increases. However, 
once a button is pressed, it is no longer taken into account.
 
All keys are pressed, display becomes “K11” .
10. “V” value increases 2, 4, 6 ... if turn the [VOLUME] knob 
clockwise, or it decreases 8, 6, 4 ... if turn the knob counter-
clockwise.
Releasing method:
Press two buttons of [ENTER] and [
x
] simultaneously, or discon-
nect the power cord.
CD  SHIP  MODE
This mode moves the optical pick-up to the position durable to 
vibration. Use this mode when returning the set to the customer 
after repair.
Procedure:
1.  Press the [
?
/
1
] button to turn the power on.
2.  Press the [FUNCTION] button to select “CD”.
3.  Press two buttons of [OPTIONS] and [
?
/
1
] simultaneously.
4.  After blink “STANDBY”, “LOCK” is displayed, disconnect 
the AC plug.
CD  SHIP  MODE  &  MEMORY  CLEAR
This mode is used to perform CD ship mode and cold reset simul-
taneously.
Procedure:
1.  Press the [
?
/
1
] button to turn the power on.
2.  Press three buttons of [
x
] and [BACK] simultaneously.
3.  After blink “STANDBY”, “LOCK” is displayed disconnect 
the AC plug.
DISC  TRAY  LOCK  MODE
This mode is used to unable to take sample disc out of disc tray in 
the shop.
Procedure:
1.  Press the [
?
/
1
] button to turn the power on.
2.  Press the [
Z
] button to open the disc tray and set the CD disc.
3.  Press the [
Z
] button to close the disc tray.
4.  Press two buttons of [
x
] and [
Z
] for 5 seconds.
5.  The message “LOCKED” is displayed on the liquid crystal el-
ement and the disc tray is locked. (Even if pressing the [
Z
] but-
ton, the message “LOCKED” is displayed on the liquid crystal 
element and the disc tray is locked)
Releasing method:
1.  Press two buttons of [
x
] and [
Z
] for 5 seconds.
2.  The message “UNLOCKED” is displayed on the liquid crystal 
element and the disc tray is unlocked.
CD  POWER  MANAGE
This mode is used to changed over CD power on/off for decreasing 
of reception noise in the tuner mode.
Procedure:
1.  Press the [
?
/
1
] button to turn the power on.
2.  Press the [FUNCTION] button to select “CD”.
3.  Press the [
?
/
1
] button again to turn the power off.
4.  Press two buttons of [  + 
v
] and [
?
/
1
] simultaneously.
5.  The message “CD POWER ON” or “CD POWER OFF” is dis-
played on the liquid crystal element, and CD power on/off is 
changed over in the tuner mode.
HCD-MX700Ni/MX750Ni
18
CD  SERVICE  MODE
This mode can run the CD sled motor freely. Use this mode, for 
instance, when cleaning the optical pick-up.
Procedure:
1.  Press the [
?
/
1
] button to turn the power on.
2.  Press the [FUNCTION] button to select “CD”.
3.  Press three buttons of [
x
] and [  + 
v
] simultaneously, the 
message “SERVICE MODE” is displayed on the liquid crystal 
element.
4.  Press the [
l m 
TUNE –] button to move the optical pick-
up to inside track and the message “SLED IN” is displayed 
on the liquid crystal element, or press the [
M L 
TUNE 
+] button to outside track and the message “SLED OUT” is 
displayed on the liquid crystal element.
5.  Press the [
u
] button, “LD ON” or “LD OFF” is displayed  on 
the liquid crystal element. Each time [
u
] button is pressed, 
laser diode on/off is changed over.
Releasing method:
Press the [
?
/
1
] button to turn off the system.
CD  SERVO  TEST  MODE
This mode can check the servo system operations of the optical 
pick-up system (= optical unit + BD96U board).
Note 1: Do not enter the [CD SERVO TEST MODE] while any other test 
mode is in progress.
Note 2: Do not enter any other test mode while the [CD SERVO TEST 
MODE] is in progress.
Note 3: In RAM Read, “SBADrough”, “SBBTrough”, “DT-GI rough”, 
“SBAD  fi ne”,  “SBBT  fi ne”,  “DT-GI  fi ne”, “DSPcomcnt”, and 
“DECcomcnt” are displayed but are not used in the service.
How to Enter the CD Servo Test Mode
Procedure:
1.  Press the [
?/1
] button to turn the power on.
2.  Press the [FUNCTION] button to select CD function.
3.  Press three buttons of [
x
], and [
V
   –] simultaneously.
4.  It enters the CD servo test mode and displays “bdt S CURVE”.
How to Exit from the CD Servo Test Mode
Procedure:
1.  To release this mode, press the [
?/1
] button.
Key Operation:
[  + 
v
], [
V
   –]: 
Use these keys to move between the seven modes contained in the 
CD Servo Test Mode, that are the S-Curve Mode, the RAM Read 
Mode, the RAM Write Mode, the Command Out Mode, the Error 
Rate Mode the LOG Initialize Mode and the LOG Read Mode as 
described below. Also, use these keys to move between the menus 
within the respective seven modes. When [  + 
v
] is pressed, the 
screen advances to the next menu or to the next mode. When [
V
 
 –] is pressed, the screen returns back to the previous menu or 
to the previous mode. Use these keys also to increase or decrease 
the numeric value when changing the numeric value. Pressing [  
v
] increases the value and pressing [
V
   –] decreases the value. 
[ENTER], [
x
]: 
Use these keys to move between the different layers of the hier-
archy of the CD Servo Test Mode shown below. Press [ENTER] 
to move down to the lower layer, and press [
x
] to move up to the 
higher layer. 
[
M L TUNE +], [l m TUNE –]: 
Use these keys to move the cursor to the right digit or to the left 
digit in the six-digit number, when changing the numeric value. 
Press [
M L TUNE +] to move the cursor to the right, and 
press [
l m TUNE –] to return the cursor to the left.
[
u
]: 
Use this key to execute Command Out in the Command Out Mode. 
CD Servo Test Mode Tree:
  
S Curve Mode 
LD ON
  
(bdt S CURVE) 
(LD ON)
  
RAM Read Mode  
Disc Type  
value indication
  
(bdtRAM READ)   
(DiscType)  
(AL: 0000, RW: 0001)
  
 
Gain Index  
value indication
  
 
(GainIndx) 
(0001)
  
 
RFO GAIN  
value indication
  
 
(RFO_GAIN)  
(0008)
  
 
FEO GAIN  
value indication
  
 
(FEO_GAIN)  
(0005)
  
 
SBAD GAIN  
value indication
  
 
(SBAD_GAIN)  
(0008)
  
 
TEO GAIN  
value indication
  
 
(TEO_GAIN)  
(0008)
  
 
Disc Size  
value indication
  
 
(DiscSize)  
(0000: Non disc, 0001: 8cm, 
  
 
0002: 
12cm)
  
 
Op ABRAKE Error   value indication
  
 
(OpAbrkErr)  
(0000)
  
 
SBBT Data  
value indication
  
 
(SBBT Data)  
(0053)
 
 
TE Peak 
value indication
  
(TE 
P-P) 
(0097)
  
 
FEOOCD  
value indication
  
 
(FEOOCD)  
(00C0)
 
 
The following items are not used (Note 3)
 
RAM Write Mode  
SPG Mask  
value edit
 
(bdtRAM WRITE)  
(00  SPG_Mask)   (Non mask:00, Mask:01)
 
 
Fix RF Gain  
value edit
 
 
(00  FixRFgain)  
(Non Fix:00, AL Fix:01, RW Fix:02)
 
 
TMAX ON  
value edit
 
 
(00  tmaxon)         
 
 
Driver Mute OFF   value edit
 
 
(00  d_muteoff)  
(Normal:00, Forced OFF:01)
 
Command Out Mode  
COMOUT6X  
value edit  
command out
 
(bdt COMOUT)  
(COMOUT6X)  
(000000)  
(ok)
 
 
READ2X  
value edit  
command out
 
 
(READ2X)  
(60)  
(50)
 
 
REG READ  
value edit  
command out
 
 
(REG_READ)  
(00)  
(0000)
 
 
FEBC?  
 
command out
  
(FEBC?) 
 
 
(00)
  
 
FGADD?  
 
command out
  
 
(FGADD?)  
 
(FA)
  
 
TEBC?  
 
command out
  
 
(TEBC?)  
 
(02)
  
 
TGADD?  
 
command out
  
 
(TGADD?)  
 
(0D)
  
 
RFGC?  
 
command out
  
 
(RFGC?)  
 
(3F)
  
 
FEOF?  
 
command out
  
 
(FEOF?)  
 
(0000)
  
 
TEOF?  
 
command out
  
 
(TEOF?)  
 
(FFC0)
  
 
TEIOCD1?  
 
command out
  
 
(TEIOCD1?)  
 
(FEC0)
  
 
TEIOCD2?  
 
command out
  
 
(TEIOCD2?)  
 
(FEC0)
  
 
TEIOCD3?  
 
command out
  
 
(TEIOCD3?)  
 
(0080)
  
 
TEOOCD?  
 
command out
  
 
(TEOOCD?)  
 
(FB80)
  
 
FEOOCD?  
 
command out
  
 
(FEOOCD?)  
 
(00C0)
  
 
MONITOR  
value edit  
command out
  
 
(MONITOR)  
(570A00)  
(ok)
  
Error Rate Mode  
 
Error rate indication
  
(bdt ERR RATE)  
 
(0000000000)
 
LOG Read Mode 
 
value indication
 
(bdtLOG READ) 
 
(XX: YYYYYY: ZZZZ)
 
 
 
XX: LOG Number
 
 
 
YYYYYY: Communication LOG
 
 
 
ZZZZ: LOG Number
 
LOG Initialize Mode   
Initializetion 
Initialization execution
 
(bdtLOG INIT) 
 
confirmation 
(INIT done)
  
 
indication 
  
 
(INIT 
sure?)
Higher layer 
Lower layer of menu hierarchy
HCD-MX700Ni/MX750Ni
19
CD  ERROR  CODE
The past errors of the CD mechanism (CDM) are displayed as the 
CDM Errors, and those of the optical pick-up system (= optical 
unit + BD96U board) are displayed as the BD Errors as shown 
below. 
Procedure:
1.   Press the [
?/1
] button to turn the power on.
2.   Press the [FUNCTION] button to select CD function.
3.  Press three buttons of [OPTIONS] and [
u
] simultaneously.
4.  BD and CDM error counts are displayed on the fl uoresent in-
dicator tube as shown below.
  Em**Ed**   X
  
Mode-in 
count
 
 
BD error count
 
 CDM error count
5.  Press the [  + 
v
] button.
6.  Then, the CDM error code is displayed as “M0xxxxxxxx” (x 
means hexadecimal number) on the liquid crystal element as 
shown below. 
7.  Every pressing of the [
M L TUNE +] button in this mode 
increments the number after “M” starting from “M0” up to 
“M9”, and then returns to “M0”. Every pressing of the [
m TUNE –] button in this mode decrements the number after 
“M”. The smaller the error code number is, the newer the error 
content is.
 
Press the [
V
   –] button to return to the previous display.
8. When the [  + 
v
] button is pressed then, the BD error code 
is displayed as “D0xxxxxxxx” (x means hexadecimal number) 
on the fl uoresent indicator tube as shown below. In the same 
way as the CDM error code, use of the [
M L TUNE +] 
and the [
l m TUNE –] buttons in this mode enables trac-
ing of the error history. 
 
Press the [
V
   –] button to return to the previous display.
Releasing method:
Press the [
?
/
1
] button to turn off the system.
Contents of “CDM Errors”
Error display example
 
M 0  FF 11 42 00
 
 
1  2  3  4 5
1  It indicates the error history number
 
0 to 9: The error code number 0 indicates the newest error.
2  It indicates whether the CDM error occurs in the normal opera-
tions or during the initialization operation. 
FF 
: The error has occurred in the normal opera-
tions. 
Other than FF :  The error has occurred during the initialization 
operation.
3 It indicates the processing during which the trouble has oc-
curred.
01: The disc EJECT processing is in progress.
02: The disc INSERTION-WAITING processing is in prog-
ress.
03: Processing of the disc INSERTION-REQUEST for the up-
per CD tray is in progress.
04: Processing of the disc EJECTION-REQUEST for the up-
per CD tray is in progress. 
05: The disc pulling-in operation is in progress.
06: The disc chucking processing is in progress.
07:  The disc re-chucking processing is in progress.
08: The disc chucking-release completion operation is in prog-
ress.
4 It indicates the operation during which the trouble has oc-
curred.
00 
: Waiting for the operation.
10 to 13 : The disc EJECT operation is in progress.
20 
: The disc pulling-in operation is in progress.
30 
: The disc chucking-release operation is in progress.
40 to 43 :  The disc EJECT operation due to error is in prog-
ress.
5 Reserve
 00: 
Fix
Contents of “BD Errors”  
Error display example
 
D  0  02 09 01 01
 
 
1  2  3  4 5
1  It indicates the error history number
 
0 to 9: The error code number 0 indicates the newest error.
2  It indicates the error content
01: The focus servo cannot lock-in.
02: GFS is no good (NG).
03: The startup time exceeds the specifi ed period of time (time 
over)
04:  The focus servo is unlocked continuously.
05:  Q code cannot be obtained within the specifi ed period of 
time.
06: The tracking servo cannot lock-in.
07: Blank disc
 
3  It indicates the on-going processing of optical pick-up system 
(= optical unit + BD96/BD96U board) when the trouble has 
occurred.
01:   The CD SHIP mode processing is in progress.
02:   The POWER OFF processing is in progress.
03:   The INITIALIZE processing is in progress.
04:   The optical pick-up system (= optical unit + BD96U) is in 
the stop state.
05:   The STOP operation is in progress.
06:   The startup processing is in progress.
07:   The TOC read-in processing is in progress.
08:   The SEARCH operation is in progress.
09:   The PLAY operation is in progress.
0A:  The PAUSE operation is in progress.
0B:  The PLAY – MANUAL SEARCH operation is in prog-
ress.
0C:  The PAUSE – MANUAL SEARCH operation is in prog-
ress.
4  It indicates the disc speed when the trouble has occurred.
 
It indicates the step number of each processing specifi ed by 
3. 
Because the numbers of steps are different in each processing, 
this number is different in each processing.
5  It indicates the disc speed when the trouble has occurred.
 
01: 1x (normal)
HCD-MX700Ni/MX750Ni
20
SECTION  4
ELECTRICAL  CHECK
FM  TUNE  LEVEL  CHECK
signal 
generator
set
Procedure:
1.  Turn on the set.
2.  Input the following signal from signal generator to FM antenna 
input directly.
Carrier frequency : A = 87.5 MHz, B = 98 MHz, C = 108 MHz
Deviation 
: 75 kHz
Modulation 
: 1 kHz
ANT input 
: 35 dBu (EMF)
Note: Use 75 ohm coaxial cable to connect signal generator and the set. 
You cannot use video cable for checking.
 
  Use signal generator whose output impedance is 75 ohm. 
3.  Set to FM tuner function and tune A, B and C signals.
4. Confi rm “TUNED” is lit on the display for A, B and C signals.
When the selected station signal is received in good condition, 
“TUNED” is displayed.