7
HCD-M700
How to Operate the Self-diagnostics Function (Error History Display Mode)
Note:
Use the self-diagnostics function in the "error history display mode" of the test mode. The least required procedure is described
below. Do not enter any other modes by mistake. If you have entered any other modes accidentally, press the  MENU/NO “R”
button to exit the mode.
1.
Press the  
?/1
  button to turn on the power.
2.
Press the  FUNCTION  button to select the “MD” function.
3.
While pressing the  x  button and the  REC MODE  button at the same time, press the  FUNCTION  button.
4.
Press the  MD 
>
 “R”  button to display “[Service]”. Then press the  ENTER/YES “R”  button.
5.
Press the  MD 
>
 “R”  button to display “Err Display”.
6.
Press the  ENTER/YES “R”  button to enter the error history display mode and  “op rec tm” appears.
7.
Select the desired contents that you want to display or to execute using the  MD 
.
 “R”  button or the  MD 
>
 “R”  button.
8.
Press the  REC MODE  button to display or to execute the selected contents.
9.
Press the  REC MODE  button again to return to step 7.
10. Press the  MENU/NO “R”  button. The message “Err Display” appears and you exit the error history mode.
11. Press the  REPEAT  button twice to exit the test mode.
12. Press the  
?/1
  button to turn off the power.
Note 1:
About “R”
As this unit has only a few buttons, some operations require the use of remote commander (RM-SM700E/provided with unit)  buttons. These
operations are indicated as “R” in this manual.
Example:  
MENU/NO “R”  
...Press the
  MENU/NO  
button of the remote commander.
Note 2:
Incorrect operations may be performed if the test mode is not entered properly.
In this case, press the  ?
/1
  button to turn the power off, and retry to enter the test mode.
8
HCD-M700
Items of Error History Mode Items and Contents
Selecting the Test Mode
Display
op rec tm
op play tm
spdl rp tm
retry err
total err
err history
retry adrs
er refresh
op change
spdl change
History
Displays the accumulated recording time.
When the accumulated recording time is more than 1 minute, displays the hour and minute
When less than 1 minute, displays “Under 1 min”
The display time indicates the time when the laser is set to high power more, which is about 1/4 of the actual
recording time.
Displays the accumulated playback time.
When the accumulated playback time is more than 1 minute, displays the hour and minute
When less than 1 minute, displays “Under 1 min”
Displays the accumulated rotating time of the spindle motor.
When the accumulated rotating time is more than 1 minute, displays the hour and minute
When less than 1 minute, displays “Under 1 min”
Displays the accumulated number of retry errors during recording and playback
Displays “r 
 p 
”. 
 is the number of errors during recording. 
 is the number of errors during playback.
This is displayed in hexadecimal from 00 to FF.
Displays the total number of errors
Displays “total 
”. This is displayed in hexadecimal from 00 to FF.
Displays the past ten errors.
Displays “0x ErrCd@@”.
X is the history number. The younger the number, the more recent is the history (00 is the latest). @@ is the
error code.
Select the error history number by pressing the  MD 
“R”  or  MD 
“R”  button.
Displays the past five retry addresses.
Displays “
 ADRS 
”, 
 is the history number, 
 is the cluster with the retry error.
Select the error history number by pressing the  MD 
“R”  or  MD 
“R”  button.
Mode for erasing the error and retry address histories
Procedure
1. Press the  REC MODE  button when displayed as “er refresh”.
2. When the display changes to “er refresh?”, press the  ENTER/YES “R”  button
When “Complete!!” is displayed, it means erasure has completed.
Be sure to check the following after executing this mode.
*Data has been erased.
*Perform recording and playback, and check that the mechanism is normal.
Mode for erasing the accumulated time of op rec tm, op play tm.
Use these histories as a guide line for the time of replacement of the optical pick-up. If the optical pick-up
has been replaced, perform this procedure and erase the past history.
Procedure
1. Press the  REC MODE  button when displayed as “op change”.
2. When the display changes to “op change?”, press the  ENTER/YES “R”  button.
When “Complete!!” is displayed, it means erasure has completed.
Mode for erasing the accumulated spdl rp tm time
Use these histories as the guide line for the time of replacement of the spindle motor. If the spindle motor has
been replaced, perform this procedure and erase the past history.
Procedure
1. Press the  REC MODE  button when displayed as “spdl change”
2. When the display changes to “spdl change?”, press the  ENTER/YES “R”  button.
When “Complete!!” is displayed, it means erasure has completed.
9
HCD-M700
Table of Error Codes
Error Code
Description
10
11
12
20
21
22
23
24
30
31
40
41
42
43
50
51
Could not perform loading
The changer error occurred
Loading switches combined incorrectly
Timed out without reading the top of PTOC
Could read top of PTOC, but detected error
Timed out without accessing UTOC
Timed out without reading UTOC
Error in UTOC
Could not start playback
Error in sector
A cause of retry occurred during normal recording
Retried due to DRAM overflow
Retry occurred during TOC writing
Retry aborted during S.F editing
Other than access processing, and could not read address.
Focus NG occurred and overran.
10
HCD-M700
Jig For Checking BD Board Waveform
The special jig (J-2501-196-A) is useful for checking the waveform of the BD board. The names of terminals and the checking items to be
performed are shown as follows.
GND : Ground
I+3V : For measuring Iop (Check the deterioration of the optical pick-up laser)
Iop
: For measuring Iop (Check the deterioration of the optical pick-up laser)
TE
: TRK error signal (Traverse adjustment)
VC
: Reference level for checking the signal
RF
: RF signal (Check jitter)
FE
: Focus error signal
I+3V
Iop
TE
VC
GND
FE
RF
CN105
I+3V
Iop
GND
TE
FE
VC
RF
I+3V
Iop
GND
TE
FE
VC
RF
1
7
for MDM-7B4M
SECTION 1
SERVICING NOTE
Page of 127
Display

Click on the first or last page to see other HCD-M700 service manuals if exist.