Sony HCD-M700 Service Manual ▷ View online
41
HCD-M700
8. Press the MD
.
“R” or MD
>
“R” button so that the
waveform of the oscilloscope becomes the specified value.
(When the MD
(When the MD
.
“R” or MD
>
“R” button is pressed,
the
of “EFB=
” changes and the waveform changes) In
this adjustment, waveform varies at intervals of approx. 2%.
Adjust the waveform so that the specified value is satisfied as
much as possible.
(Write power traverse adjustment)
Adjust the waveform so that the specified value is satisfied as
much as possible.
(Write power traverse adjustment)
Traverse Waveform
9. Press the ENTER/YES “R”
button, and save the adjustment
results in the non-volatile memory. (“EFB =
SAVE” will
be displayed for a moment)
10. “EFB =
MO-P” will be displayed.
The optical pick-up moves to the pit area automatically and
servo is imposed.
servo is imposed.
11. Press the MD
.
“R” or MD
>
“R” button until the
waveform of the oscilloscope moves closer to the specified value.
In this adjustment, waveform varies at intervals of approx. 2%.
Adjust the waveform so that the specified value is satisfied as
much as possible.
In this adjustment, waveform varies at intervals of approx. 2%.
Adjust the waveform so that the specified value is satisfied as
much as possible.
Traverse Waveform
12. Press the ENTER/YES “R”
button, and save the adjustment
results in the non-volatile memory. (“EFB =
SAVE” will
be displayed for a moment)
Next “EF MO ADJUST” (C07) is displayed. The disc stops
rotating automatically.
Next “EF MO ADJUST” (C07) is displayed. The disc stops
rotating automatically.
13. Press the Z MD button and take out the disc.
14. Load the check disc (TDYS-1).
15. Press the MD
14. Load the check disc (TDYS-1).
15. Press the MD
.
“R” or MD
>
“R” button to display
“EF CD ADJUST” (C08).
16. Press the ENTER/YES “R”
button to display “EFB =
CD”. Servo is imposed automatically.
17. Press the MD
.
“R” or MD
>
“R” button so that the
waveform of the oscilloscope moves closer to the specified value.
In this adjustment, waveform varies at intervals of approx. 2%.
Adjust the waveform so that the specified value is satisfied as
much as possible.
In this adjustment, waveform varies at intervals of approx. 2%.
Adjust the waveform so that the specified value is satisfied as
much as possible.
Traverse Waveform
18. Press the ENTER/YES “R”
button, display “EFB =
SAVE”
for a moment and save the adjustment results in the non-volatile
memory.
Next “EF CD ADJUST” (C08) will be displayed.
memory.
Next “EF CD ADJUST” (C08) will be displayed.
19. Press the Z MD button and take out the check disc.
Adjustment Location: BD board (see page 43)
13. Focus Bias Adjustment
Procedure:
1. Load the check disc (MDW-74/GA-1).
2. Press the MD
1. Load the check disc (MDW-74/GA-1).
2. Press the MD
.
“R” or MD
>
“R” button to display
“CPLAY1 MODE” (C34).
3. Press the ENTER/YES “R”
button to display “CPLAY 1MID”.
4. Press the
MENU/NO “R”
button when “C =
AD =
)” is displayed.
5. Press the MD
.
“R” or MD
>
“R” button to display
“FBIAS ADJUST” (C09).
6. Press the ENTER/YES “R” button to display “
/
a
=
T”.
The first four digits indicate the C error rate, the two digits
after “/ ” indicate ADER, and the 2 digits after “a =” indicate
the focus bias value.
after “/ ” indicate ADER, and the 2 digits after “a =” indicate
the focus bias value.
7. Press the
>
“R” button and find the focus bias value at
which the C error rate becomes about 200 (refer to Note 2).
8. Press the ENTER/YES “R”
button to display “
/
b
=
T”.
9. Press the
.
“R” button and find the focus bias value at
which the C error rate becomes about 200.
10. Press the ENTER/YES “R”
button to display “
/
c
=
T”.
11. Check that the C error rate is below 20 and ADER is 00. Then
press the ENTER/YES “R”
button.
12. If the “(
)” in “
-
-
(
)” is above 20, press the
ENTER/YES “R”
button.
If below 20, press the
MENU/NO “R”
button and repeat the
adjustment from step 2.
13. Press thet Z MD button and take out the disc.
Note 1:
The relation between the C error and focus bias is as shown in
the following figure. Find points A and B in the following figure
using the above adjustment. The focal point position C is auto-
matically calculated from points A and B.
the following figure. Find points A and B in the following figure
using the above adjustment. The focal point position C is auto-
matically calculated from points A and B.
Note 2:
As the C error rate changes, perform the adjustment using the
average vale.
average vale.
A
B
VC
Specification A = B
A
B
VC
Specification A = B
A
B
VC
Specification A = B
C error
about
200
200
B
C
A
Focus bias value
42
HCD-M700
14. Error Rate Check
14-1. CD Error Rate Check
Procedure:
1. Load the check disc (TDYS-1).
2. Press the MD
1. Load the check disc (TDYS-1).
2. Press the MD
.
“R” or MD
>
“R” button and display
“CPLAY1 MODE” (C34).
3. Press the ENTER/YES “R”
button twice and display “CPLAY1
MID”.
4. The display changes to “C =
AD =
)”.
5. Check that the C error rate is below 20.
6. Press the
6. Press the
MENU/NO “R”
button to stop playback, then press
the Z MD button and take out the check disc.
14-2. MO Error Rate Check
Procedure:
1. Load the continuously-recorded disc. (Refer to “5. USING
1. Load the continuously-recorded disc. (Refer to “5. USING
THE CONTINUOUSLY RECORDED DISC” (See page 36))
2. Press the MD
.
“R” or MD
>
“R” button to display
“CPLAY1 MODE” (C34).
3. Press the ENTER/YES “R”
button to display “CPLAY1MID”.
4. The display changes to “C =
AD =
)”.
5. If the C error rate is below 20, check that ADER is 00.
6. Press the
6. Press the
MENU/NO “R”
button to stop playback, then press
the Z MD button and take out the disc.
15. Focus Bias Check
Change the focus bias and check the focus tolerance amount.
Procedure:
1. Load the continuously-recorded disc. (Refer to “5. USING
1. Load the continuously-recorded disc. (Refer to “5. USING
THE CONTINUOUSLY RECORDED DISC” (See page 36))
2. Press the MD
.
“R” or MD
>
“R” button to display
“CPLAY1 MODE” (C34).
3. Press the ENTER/YES “R”
button twice to display “CPLAY1
MID”.
4. Press the
MENU/NO “R”
button when “C =
AD =
)” is displayed.
5. Press the MD
.
“R” or MD
>
“R” button to display
“FBIAS CHECK” (C16).
6. Press the ENTER/YES “R”
button to display “
/
c =
”.
The first four digits indicate the C error rate, the two digits after
“/ ” indicate ADER, and the 2 digits after “c =” indicate the
focus bias value.
“/ ” indicate ADER, and the 2 digits after “c =” indicate the
focus bias value.
7. Press the ENTER/YES “R”
button and display “
/
b
=
”.
Check that the C error is below 220 and ADER is below 2.
8. Press the ENTER/YES “R”
button and display “
/
a
=
”.
Check that the C error is below 220 and ADER is below 2
9. Press the
MENU/NO “R”
button, then press the Z MD button
and take out the disc.
Note:
If the C error and ADER are above other than the specified value
at points a (step 8. in the above) or b (step 7. in the above), the
focus bias adjustment may not have been carried out properly.
Adjust perform the beginning again.
at points a (step 8. in the above) or b (step 7. in the above), the
focus bias adjustment may not have been carried out properly.
Adjust perform the beginning again.
16. Auto Gain Control Output Level Adjustment
Be sure to perform this adjustment when the optical pick-up is
replaced.
If the adjustment results becomes “Adjust NG!”, the optical pick-
up may be faulty or the servo system circuits may be abnormal.
replaced.
If the adjustment results becomes “Adjust NG!”, the optical pick-
up may be faulty or the servo system circuits may be abnormal.
16-1. CD Auto Gain Control Output Level Adjustment
Procedure:
1. Load the check disc (TDYS-1).
2. Press the MD
1. Load the check disc (TDYS-1).
2. Press the MD
m
“R” or MD
>
“R” button to display “AG
Set (CD)” (C11).
3. When the ENTER/YES “R”
button is pressed, the adjustment
will be performed automatically.
“Complete!” will then be displayed momentarily when the value
is recorded in the non-volatile memory, after which the display
changes to “AG Set (CD)” (C11).
“Complete!” will then be displayed momentarily when the value
is recorded in the non-volatile memory, after which the display
changes to “AG Set (CD)” (C11).
4. Press the Z MD button and take out the check disc.
16-2. MO Auto Gain Control Output Level Adjustment
Procedure:
1. Load the test disc (MDW-74/GA-1).
2. Press the MD
1. Load the test disc (MDW-74/GA-1).
2. Press the MD
.
“R” or MD
>
“R” button to display
“AG Set (MO)” (C10).
3. When the ENTER/YES “R”
button is pressed, the adjustment
will be performed automatically.
“Complete!” will then be displayed momentarily when the value
is recorded in the non-volatile memory, after which the display
changes to “AG Set (MO)” (C10).
“Complete!” will then be displayed momentarily when the value
is recorded in the non-volatile memory, after which the display
changes to “AG Set (MO)” (C10).
4. Press the Z MD button and take out the test disc.
43
HCD-M700
Adjustment and checking Loacation:
Note:
It is useful to use the jig for checking the waveform. (Refer to Ser-
vicing Notes on page 10)
vicing Notes on page 10)
D101
CN101
CN103
CN102
CN105
IC151
IC102
IC101
IC195
IC190
1
1
1
7
27
17
– BD BOARD (Side A) –
– BD BOARD (Side B) –
44
HCD-M700
Syscon Diagnosis
The same contents as board detail check by serial interface can be
checked from the remote commander.
On the Test Mode Menu screen, press the 0 “R” key on the remote
commander, and the following Check Menu will be displayed.
checked from the remote commander.
On the Test Mode Menu screen, press the 0 “R” key on the remote
commander, and the following Check Menu will be displayed.
### Syscon Diagnosis ###
Check Menu
0. Quit
1. All
2. Version
3. Peripheral
4. Servo
5. Supply
6. AV Decoder
7. Video
8. Audio
_
0. Quit
Quit the Syscon Diagnosis and return to the Test Mode Menu.
1. All
This menu checks all diagnostic items continuously. Normally, all
items are checked successively one after another automatically
unless an error is found, but at a certain item that requires judgment
through a visual check to the result, the following screen is displayed
for the key entry.
items are checked successively one after another automatically
unless an error is found, but at a certain item that requires judgment
through a visual check to the result, the following screen is displayed
for the key entry.
### Syscon Diagnosis ###
Diag All Check
No. 2 Version
2-3. ROM Check Sum
Check Sum = 2005
Press NEXT Key to Continue
Press PREV Key to Repeat
_
For the ROM Check, the check sum calculated by the syscon is
output, and therefore you must compare it with the specified value
for confirmation. Following the message, press the DVD > “R”
key to go to the next item, or the DVD . “R” key to repeat the
same check again. To quit the Syscon Diagnosis and return to the
Check Menu screen, press the DVD x “R” or the ENTER “R”
keyon the remote commander. If an error occurred, the diagnosis is
suspended and the error code is displayed as shown below.
output, and therefore you must compare it with the specified value
for confirmation. Following the message, press the DVD > “R”
key to go to the next item, or the DVD . “R” key to repeat the
same check again. To quit the Syscon Diagnosis and return to the
Check Menu screen, press the DVD x “R” or the ENTER “R”
keyon the remote commander. If an error occurred, the diagnosis is
suspended and the error code is displayed as shown below.
### Syscon Diagnosis ###
3-3. EEPROM Check
Error 03: EEPROM Write/Reed N
Address
: 00000001
Write Data : 2492
Read Data
: 2490
Press NEXT Key to Continue
Press PREV Key to Repeat
_
[DVD Service Mode]
• This mode allows you to make diagnosis and adjustment easily
using the remote commander and monitor TV. The instructions,
diagnostic results, etc. are given on the on-screen display (OSD).
diagnostic results, etc. are given on the on-screen display (OSD).
Entering the DVD Service Mode
Procedure:
1. Press the ?/1 key or the ?/1 “R” button to turn the power ON.
2. Press the FUNCTION key to select “DVD”.
3. Press three keys x , ENTER/START , and VOLUME +
1. Press the ?/1 key or the ?/1 “R” button to turn the power ON.
2. Press the FUNCTION key to select “DVD”.
3. Press three keys x , ENTER/START , and VOLUME +
simultaneously.
4. Test mode start and display the menu shown below on the TV
screen. (At the bottom of the menu screen, the model name and
revision number are displayed)
revision number are displayed)
5. To execute each function, select the desired menu and press its
number on the remote commander. To release from this mode,
press the ?/1 key.
press the ?/1 key.
Test Mode Menu
0. Syscon Diagnosis
1. Drive Auto Adjustment
2. Drive Manual Operation
3. Mecha Aging
4. Emergency History
5. Version Information
6. Video Level Adjustment
Exit: POWER Key
_
Model
: HCX-1162_xx
Revision : 1.xxx
Note 1:
About “R”
As this unit has only a few buttons, some operations require
the use of remote commander (RM-SM700E/provided with
unit) buttons. These operations are indicated as “R” in this
manual.
Example: MENU/NO “R” ...Press the MENU/NO button
of the remote commander.
As this unit has only a few buttons, some operations require
the use of remote commander (RM-SM700E/provided with
unit) buttons. These operations are indicated as “R” in this
manual.
Example: MENU/NO “R” ...Press the MENU/NO button
of the remote commander.
Note 2:
Incorrect operations may be performed if the test mode is not
entered properly.
In this case, press the
entered properly.
In this case, press the
?/1
button to turn the power off, and
retry to enter the test mode.
[Disc Tray Lock]
Procedure:
1. Press the ?/1 button or the ?/1 “R” button of remote
1. Press the ?/1 button or the ?/1 “R” button of remote
commander to turn on the power.
2. Press the FUNCTION button to enter the “DVD” mode.
3. Press the ENTER/START button and the DVD Z button at
3. Press the ENTER/START button and the DVD Z button at
the same time for 5 seconds or longer.
4. The message “LOCKED” appears and the tray is locked. (The
tray is kept lock even after exiting this mode.)
5. Press ENTER/START button and the DVD Z button again at
the same time for 5 seconds or longer.
6. The message “UNLOCKED” appears and the tray lock is
released.
DVD SECTION