DOWNLOAD Sony HCD-GZR333IA Service Manual ↓ Size: 4.92 MB | Pages: 98 in PDF or view online for FREE

Model
HCD-GZR333IA
Pages
98
Size
4.92 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
hcd-gzr333ia.pdf
Date

Sony HCD-GZR333IA Service Manual ▷ View online

HCD-GZR333IA
21
[PANEL  TEST  MODE]
•  This mode is used to check the LCD module, LEDs, button, 
MASTER VOLUME dial, OPERATION DIAL ring, system 
software version, DVD lib version, model name and destina-
tion.
Procedure:
1.  Press the [
?/1
] button to turn on the system.
2.  Press the [
x
] button, [DISC 3] button and [USB] button simul-
taneously.
3.  Power illuminator LEDs and segment in LCD module are 
lighted up.
4.  When you want to enter to the system software version display 
model, press the [DISC 1] button. The system software version 
appears on the LCD module. 
 
Press the [DISC 1] button again, the DVD lib version appears 
on the LCD module.
5.  Press the [DISC 2] button the mode name and destination on 
the LCD module.
6.  Press the [DISC 3] button the key encode test mode is acti-
vated.
7.  In the key encode test mode, the LCD module displays “KEY 
0 0 0 0 0”. 
 
Each time a button pressed, change the each numbers.
•  To release from Panal Test Mode
1.  To release from this mode, press the [
x
] button, [DISC 3] but-
ton and [USB] button simultaneously.
[DVD  SHIP  MODE (WITHOUT  MEMORY  CLEAR)]
•  This mode moves the optical pick-up to the position durable 
to vibration. Use this mode when returning the set to the cus-
tomer after repair.
Procedure:
1.  Press the [
?/1
] button to turn on the system.
2.  Press the [DVD] button, to set the “NO DISC” mode.
3.  Press the [
N
] button and [
?/1
] button simultaneously.
 
The system will turn off automatically.
4.  After the “STANDBY” blinking display fi nishes, a message 
“LOCK” appears on the LCD module and the DVD ship mode 
is set.
•  To release from DVD Ship Mode
1.  To release from this mode, press the [
?/1
] button.
[DVD  SHIP  MODE (WITH  MEMORY  CLEAR)]
•  This mode moves the optical pick-up to the position durable 
to vibration and clears all data including preset data stored in 
the RAM to initial conditions after the power supply is turned 
off. Use this mode when returning the set to the customer after 
repair.
Procedure:
1.  Press the [
?/1
] button to turn on the system.
2.  Press the [DVD] button, to set the “NO DISC” mode.
3.  Press the [TUNING –] button, [DISC 3] button and [
?/1
] but-
ton simultaneously.
4.  After the “STANDBY” blinking display fi nishes, a message 
“COLD RESET” appears on the LCD module and the DVD 
ship mode is set.
•  To release from DVD Ship Mode
1.  To release from this mode, press the [
?/1
] button.
[DISC  THEFT  PREVENTION  MODE]
•  This mode let you lock the disc tray. When this mode is acti-
vated, the disc tray will not open.
Procedure:
1.  Press the [
?/1
] button to turn on the system.
2.  Press the [DVD] button.
3. Press the [
x
] button and [OPEN/CLOSE 
Z
] button simulta-
neously and hold down until “LOCKED” or “UNLOCKED” 
appears on the LCD module (around 5 seconds).
•  To release from Disc Theft Prevention Mode
1.  This mode will not be deselected only by turning the power 
off. To exit from the mode, perform the above item 3 again.
[DVD  COLOR  SYSTEM  MODE]
•  This mode let you change the color system of the video output 
from PAL to NTSC or vice-versa.
Procedure:
1.  Press the [
?/1
] button to turn on the system.
2.  Press the [DVD] button.
3.  Press the [
?/1
] button to turn off the system.
4.  Press the [DISPLAY] button to switch the mode the clock dis-
play or demonstration mode.
5.  Press the [
X
] button and [
?/1
] button simultaneously.
 
The system will turn on automatically.
6.  The message “COLOR PAL” or “COLOR NTSC” appears on 
the LCD module.
•  To release from DVD Color System Mode
1.  Once the color system has been selected, the mode is fi xed 
there after. If you wish to change the mode again, perform the 
above item 4 again.
[DVD  FIRMWARE  VERSION  MODE]
•  This mode is used to display the DVD fi rmware version.
Procedure:
1.  Press the [
?/1
] button to turn on the system.
2.  Press the [DVD] button.
3  Press the [
?/1
] button to turn off the system and enter the 
clock display or demonstration mode.
4.  Press the [
x
] button and [
?/1
] button simultaneously.
5.  The version of DVD fi rmware appears on the on-screen dis-
play on TV.
•  To release from DVD Firmware Version Mode
1.  To release from this mode, press the [
?/1
] button.
[MTK  REBOOT  AVOIDANCE  MODE]
•  This mode is used to display the MTK Reboot Avoidance.
Procedure:
1.  Press the [
?/1
] button to turn on the system.
2.  Press the [DVD] button.
3.  Press the [DVD] button, [OPEN/CLOSE 
Z
] button and [TUN-
ING +] button simultaneously.
4.  The message “MTK DBG” appears on the LCD module.
•  To release from MTK Reboot Avoidance Mode
1.  To release from this mode, press the [
?/1
] button.
HCD-GZR333IA
22
[AM  TUNER  STEP  CHAGE]
•  The step interval of AM channels can be toggled between 9 
kHz and 10 kHz.
Procedure:
1.  Press the [
?/1
] button to turn on the system.
2.  Press the [TUNER/BAND] button repeatedly to select the 
“AM”.
3.  Press the [
?/1
] button to turn off the system.
4.  Press the [TUNING +] button and [
?/1
] button simultane-
ously.
 
The system will turn on automatically.
5.  The message “AM 9K STEP” or “AM 10K STEP” appears on 
the LCD module and thus the channel step change.
[VIDEO/SAT  FUNCTION  CHANGE]
•  This mode let you change from VIDEO to SAT and vice-versa.
Procedure:
1.  Press the [
?/1
] button to turn on the system.
2.  Press the [VIDEO/SAT] button.
3.  Press the [VIDEO/SAT] button and [
x
] button simultaneously. 
The function will change to SAT.
4.  Press the same button again to change from SAT to VIDEO.
[DVD  SERVICE  MODE]
•  This mode let you make diagnosis and adjustment easily by 
using the remote commander and the TV. The instructions, di-
agnostic results, etc. are given on the on-screen display.
•   TEST  DISC  LIST
 
Be sure to use the DVD disc that matches the signal standards 
of your region.
• CD
   
 
  YEDS-18  (Part No.: 3-702-101-01)
   
 
  PATD-012 (Part No.: 4-225-203-01)
•  DVD SL (Single Layer)
   
NTSC : HLX-503  (Part No.: J-6090-069-A)
   
 
  HLX-504  (Part No.: J-6090-088-A)
   
PAL  : HLX-506  (Part No.: J-6090-077-A)
•  DVD DL (Double Layer)
   
NTSC : HLX-501  (Part No.: J-6090-071-A)
   
 
  HLX-505  (Part No.: J-6090-089-A)
   
PAL  : HLX-507  (Part No.: J-6090-078-A)
•  Procedure to enter to DVD Service Mode:
1.  Press the [
?/1
] button to turn on the system.
2.  Press the [DVD] button.
3. Press 
the 
[
x
] button and [OPEN/CLOSE 
Z
] button simultane-
ously and then turn the [MASTER VOLUME] dial clockwise.
4.  The message “SERVICE IN” appears on the LCD module and 
the Top Menu of Remocon Diagnosis Menu appears on the on-
screen display on the TV. The model name, main unit’s micom 
version information (IF-con) and DVD fi rmware version infor-
mation (Syscon) are displayed at the bottom of the on-screen 
display.
 
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
Model Name
IF-con
Syscon
: SVX3DI_XX
: Ver.  01.00 (0000)
: Ver.  1.200
5.  To execute each function, press its number by using numeric 
button on the remote commander.
6.  To release from this mode, press the [
?/1
] button to turn off 
the system.
•  Execute IOP Measurement
 
In order to execute IOP measurement, the following standard 
procedures must be followed.
1.  From the Top Menu of Remocon Diagnosis Menu, select “2. 
Drive Manual Operation” by pressing the [2] button on the 
remote commander. The following screen appears on the on-
screen display.
 
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Mecha test mode
5. MIRR time Adjust
0. Return to Top Menu
2.  Select “3. Manual Adjustment” by pressing the [3] button on 
the remote commander. The following screen appears on the 
on-screen display.
 
 
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg Boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve (FE) Level:
9. RFL (PI) Level:
0. MIRR Time:
O
 
o Change Value
RETURN  Return to previous menu
HCD-GZR333IA
23
3.  Select “6. Iop:” by pressing the [6] button on the remote com-
mander.
4.  Wait until a hexadecimal number appears in the on-screen dis-
play as below:
 
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg Boost Adjust:
6. Iop. ED
7. TRV. Level:
8. S curve (FE) Level:
9. RFL (PI) Level:
0. MIRR Time:
O
 
o Change Value
RETURN  Return to previous menu
5.  Convert data from hexadecimal to decimal by using conver-
sion table.
6. Please 
fi nd the label on the rear of the BU (Base Unit).
 
The default IOP value is written in the label.
7.  Subtract between these two values.
8.  If the remainder is smaller than 93 (decimal), then it is OK.
 
However if the value is higher than 93, then the BU is defec-
tive and need to be change.
9.  Press the [RETURN] button on the remote commander to re-
turn to previous menu.
10. Press the [0] button on the remote commander to return to the 
Top Menu of Remocon Diagnosis Menu.
11.  Press the [
?/1
] button to turn off the system.
•  Check Emergency History
 
To check the emergency history, please follow the following 
procedure.
1.  From the Top Menu of Remocon Diagnosis Menu, select “3. 
Emergency History” by pressing the [3] button on the remote 
commander. The following screen appears on the on-screen 
display.
 
Emg. History Check
1.  01  05  04  04
Laser Hours
CD
999h
59min
DVD
999h
59min
00  92  46  00
00  00  00  00
00  00  23  45
2.  02  02  01  01
00  A9  4B  00
00  00  00  00
00  00  23  45
Next   Next Page
Prev   Prev Page
O  Return to Top Menu
2.  You can check the total time when the laser is turned on during 
playback of DVD and CD from the above menu. The maxi-
mum time, which can be displayed are 999h 59min.
3.  You can check the error code of latest 10 emergency history 
from the above menu. To view the previous or next page of 
emergency history, press the [
.
] button or [
>
] button on 
the remote commander. The error code consists of
• Error 
Code
 
Example of Error code
1.  01  05  04  04
00  92  46  00
00  00  00  00
00  00  23  45
 
The meaning of error code is as below:
 
01: Communication error (No reply from syscon)
 
02: Syscon hung up
 
03: Power OFF request when syscon hung up
 19: 
Thermal 
shutdown
 24: 
MoveSledHome 
error
 
25: Mechanical move error (5 Changer)
 
26: Mechanical move stack error
 
30: DC motor adjustment error
 
31: DPD offset adjustment error
 
32: TE balance adjustment error
 
33: TE sensor adjustment error
 
34:  TE loop gain adjustment error
 
35:  FE loop gain adjustment error
 
36:  Bad jitter after adjustment
 
40:  Focus NG
 
42:  Focus layer jump NG
 
51:  Spindle stop error
 
52:  Open kick spindle error
 
60:  Focus on error
 
61:  Seek fail error
 
62:  Read Q data/ID error
 
70:  Lead in data read fail
 
71:  TOC read time out (CD)
 
80:  Can’t buffering
 
81:  Unknown media type
•  Parameter of error code
 
This is the detail of error code.
 
Example of Error code
1.  01  05  04  04
00  92  46  00
00  00  00  00
00  00  23  45
•  Time of error code
 
This is the laser time when an error occurred.
 
Example of Error code
1.  01  05  04  04
00  92  46  00
00  00  00  00
00  00  23  45
To clear the Laser Hours
Press the [  DISPLAY] button and then press the [CLEAR] but-
ton. The data for both CD and DVD data are reset.
 
Emg. History Check
1.  01  05  04  04
Laser Hours
CD
0h
0min
DVD
0h
0min
00  92  46  00
00  00  00  00
00  00  23  45
2.  02  02  01  01
00  A9  4B  00
00  00  00  00
00  00  23  45
Next   Next Page
Prev  Prev Page
O  Return to Top Menu
HCD-GZR333IA
24
To clear the Emergency History
Press the [DVD TOP MENU] button and then press the [CLEAR] 
button.
The error code for all emergency history would be reset.
 
Emg. History Check
1.  00  00  00  00
Laser Hours
CD
999h
59min
DVD
999h
59min
00  00  00  00
00  00  00  00
00  00  00  00
2.  00  00  00  00
00  00  00  00
00  00  00  00
00  00  00  00
Next   Next Page
Prev   Prev Page
O  Return to Top Menu
To clear the Initialize Setup Data
Press the [DVD/TUNER MENU] button and then press the 
[CLEAR] button on the remote commander.
 
Emg. History Check
Initialize setup data...
Laser Hours
CD
999h
59min
DVD
999h
59min
Next   Next Page
Prev   Prev Page
O  Return to Top Menu
To return to the Top Menu of Remocon Diagnosis Menu
Press the [0] button on the remote commander.
•  Check Version Information
 
To check the version information, please follow the following 
procedure.
1.  From the Top Menu of Remocon Diagnosis Menu, select “4. 
Version information” by pressing the [4] button on the remote 
commander. The following screen appears on the on-screen 
display.
 
Version information
O  Return to Top Menu
Firm (Main) :  Ver. xxxxx
Firm (Sub) :  xxxxx
RISC :   xxxxx
8032 :   xxxxx
Audio DSP :  xxxxx
Servo DSP :  xxxxx
 
To return to the Top Menu of Remocon Diagnosis Menu, press 
the [0] button on the remote commander.
SECTION  4
ELECTRICAL  ADJUSTMENTS
When the optical pick-up assy is replaced, perform the “Execute 
IOP Measurement”.
 
Execute IOP Measurement (See page 22)
[TEST  DISC  LIST]
Be sure to use the DVD disc that matches the signal standards of 
your region.
•  CD
 
 
  YEDS-18  (Part No.: 3-702-101-01)
 
 
  PATD-012 (Part No.: 4-225-203-01)
•  DVD SL (Single Layer)
 
NTSC : HLX-503  (Part No.: J-6090-069-A)
 
 
  HLX-504  (Part No.: J-6090-088-A)
 
PAL  : HLX-506  (Part No.: J-6090-077-A)
•  DVD DL (Double Layer)
 
NTSC : HLX-501  (Part No.: J-6090-071-A)
 
 
  HLX-505  (Part No.: J-6090-089-A)
 
PAL  : HLX-507  (Part No.: J-6090-078-A)
[RFMON Level Check]
Connection:
+
CN105 pin 6 (RFMON)
CN105 pin 3 (GND)
oscilloscope 
DMB19 board
Procedure:
1.  Connect an oscilloscope to CN105 pin 6 (RFMON) and 
CN105 pin 3 (GND) on the DMB19 board.
2.  Turn the power on.
3.  Set the test disc (refer to the TEST DISC LIST) on the tray and 
press the [
N
] button to playback.
4. Confi rm that oscilloscope waveform is clear and check RF-
MON signal level is correct or not.
Note: A clear RFMON signal waveform means that the shape “◊” can be 
clearly distinguished at the center of the waveform.
RFMON signal waveform
VOLT/DIV: 200 mV
TIME/DIV: 500 nS
level: 0.58 ± 1.23 Vp-p (DVD)
         0.57 ± 1.1 Vp-p (CD)
DVD  SECTION