DOWNLOAD Sony HCD-GPX5G / HCD-GPX7G / HCD-GPX8G Service Manual ↓ Size: 6.11 MB | Pages: 87 in PDF or view online for FREE

Model
HCD-GPX5G HCD-GPX7G HCD-GPX8G
Pages
87
Size
6.11 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
hcd-gpx5g-hcd-gpx7g-hcd-gpx8g.pdf
Date

Sony HCD-GPX5G / HCD-GPX7G / HCD-GPX8G Service Manual ▷ View online

HCD-GPX5G/GPX7G/GPX8G
17
2-15.  SENSOR  BOARD
3 wire (flat type) (5 core)
 (CN742)
4 two screws
 (+BTTP 
(M2.6))
5 motor assy, table (M741)
6 remove the two solderings of motor
7 MOTOR (TB) board
1 gear (stopper)
1 gear (stopper)
2
table
2-16.  MOTOR  (TB)  BOARD
1 floating screw
 (+PTPWH 
M2.6)
4 floating screw
 (+PTPWH 
M2.6)
8 one screw
 (+BTTP 
(M2.6))
6 floating screw
 (+PTPWH 
M2.6)
7 gear (geneva)
2 tray
3 belt (table)
9 CN731
 (3P)
0 SENSOR board
5 pulley (table)
HCD-GPX5G/GPX7G/GPX8G
18
2-17.  MOTOR  (LD)  BOARD
1 belt (loading)
2 remove the two solderings of motor
4 motor assy, loading (M751)
5 MOTOR (LD) board
3 two screws
 (+BTTP 
(M2.6))
HCD-GPX5G/GPX7G/GPX8G
19
SECTION  3
TEST  MODE
[PANEL TEST MODE]
 
•  This mode is used to check the fl uorescent indicator tube, 
LEDs, keys, [MASTER VOLUME] jog, model, destina-
tion and software version.
 • 
Procedure:
 
1. Press [CD/DISC SKIP] button and [TUNER/BAND] 
button simultaneously and hold 3 seconds.
 
2.  All LEDs and segments in fl uorescent indicator tube are 
lighted up. 
 
3. When you want to enter to the software version display 
mode, press [
+
 / 
] button. The model information 
appears on the fl uorescent indicator tube. 
 
  • “GPX 3S”  is shown for MHC-GPX5.
 
  • “GPX 4” is shown for MHC-GPX7.
 
  • “GPX 7S” is shown for MHC-GPX8.
 Press 
[
+
 / 
] button again to view the destination 
 information.
 
4. During the destination information display, press [
+
 
] button. Each time [
+
 / 
] button is pressed, the 
fl uorescent indicator tube shows the version of each category 
software in the following sequence: SC, MTK (DMB Board 
fi rmware version), UI, PF, SYS, CD, CDMA, CDMB, 
ST, TA, TAS, TM and return back to model information 
display.
 
5.  
When [OPTION] button is pressed while the version 
numbers are being displayed except model and destination, 
the date of the software creation appears. When [OPTION] 
button is pressed again, the display returns to the software 
version display. 
 6. 
Press 
[
+
 / ↓] button, the key check mode is activated.
 
7.  In the key check mode, the fl uorescent indicator tube 
displays “K 0    V0”.
 
 
Each time a button is pressed, “K” value increases. 
 
  However, once a button has been pressed, it is no longer 
taken into account. 
 
 
“V” value increases in the manner of 0,1, 2, 3 ... if [MAS-
TER VOLUME] knob is turned clockwise, or it decreases 
in the manner of 0, 9, 8,7  ... if [MASTER VOLUME] knob 
is turned counterclockwise.
 
8. When [ENTER] button is pressed after all LEDs and 
segments in fl uorescent indicator tube light up, alternate 
segments in fl uorescent indicator tube and LEDs would 
light up. If you press [ENTER] button again, another half 
of alternate segments in fl uorescent indicator tube and 
LEDs would light up.  Pressing [ENTER] button again 
would cause all segments in fl uorescent indicator tube and 
LEDs light up.
 
9.  To release from this mode, press three buttons in the same 
manner as step 1, or disconnect the power cord.
[COMMON  TEST  MODE]
 
•  This mode is used to check operations of the Amplifi er 
section.
 • 
Procedure:
 
•  To enter Common Test Mode
 
1.  Press [USB/USB SELECT] button and [BASS BAZUCA] 
button simultaneously and hold for 3 seconds.
 
2.  The function is changed to TV and the volume is changed 
to VOLUME MIN.
 • 
Check 
of 
Amplifi er
 
1.  Press [MUSIC] button repeatedly until a message “GEQ 
MAX” appears on the fl uorescent indicator tube. GEQ in-
creases to its maximum.
 
2.  Press [MUSIC] button repeatedly until a message “GEQ 
MIN” appears on the fl uorescent indicator tube. GEQ 
decreases to its minimum.
 
3.  Press [MUSIC] button repeatedly until a message “GEQ 
FLAT” appears on the fl uorescent indicator tube. GEQ is 
set to fl at.
 
4.  When the [MASTER VOLUME] knob is turned clockwise 
even slightly, the sound volume increases to its maximum 
and a message “VOLUME MAX” appears on the fl uores-
cent indicator tube.
 
5.  When the [MASTER VOLUME] knob is turned counter-
clockwise even slightly, the sound volume decreases to its 
minimum and a message “VOLUME MIN” appears on the 
fl uorescent indicator tube.
 
•  To release from Common Test mode
 
1.  To release from this mode, press [
I/1 STANDBY
] button.
 
2.  The cold reset is enforced at the same time.
[USER RESET]
 
•  The user reset clears all data including preset data stored 
in the data fl ash to initial conditions exclude history mode 
data
 • 
Procedure:
 1. 
Press 
[
I/1 STANDBY
] button to turn on the system.
 2. 
Press [
x
] button and [
I/1 STANDBY
] button simultane 
  ously for 3 seconds.
 
3.“RESET” appears on the fl uorescent indicator tube. 
 After 
that, 
the 
fl uorescent indicator tube becomes blank 
  for a while, and the system is reset.
[COLD RESET]
 
•  The cold reset clears all data including preset data stored in 
the data fl ash to initial conditions. Execute this mode when 
returning the set to the customer.
 • 
Procedure:
  
1. 
Press 
[
I/1 STANDBY
] button to turn on the system.
 
  2. 
Press [ENTER] button and [GAME] button 
 
   
simultaneously for 3 seconds.
 
  3. 
“COLD RESET” appears on the fl uorescent 
 
   
indicator tube. After that, the fl uorescent indicator  
   
tube becomes blank for a while, and the system is  
  
reset.
[TUNER STEP CHANGE]
 
•  The step interval of AM channels can be toggled between 
9 kHz and 10 kHz. This mode is not available for Saudi 
Arabian, European and Russian models.
 • 
Procedure:
  
1. 
Press 
[
I/1 STANDBY
] button to turn on the system.
 
  2. 
Press [TUNER/BAND] button repeatedly to select 
  
 
the 
“AM”.
  
3. 
Press 
[
I/1 STANDBY
] button to turn off the system.
 
  4. 
Press [LED EFFECT] button and [
I/1 STANDBY
 
   
button simultaneously. The system turns on 
 
   
automatically. The message “AM  9K STEP” 
 
   
or “AM   10K STEP” appears on the fl uorescent 
 
   
indicator tube and thus the channel step is changed.
[CD SHIP MODE (WITH MEMORY CLEAR)]
 
•  This mode moves the optical pick-up to the position 
durable to vibration and clears all data including preset 
data stored in the EEPROM to initial conditions during the 
next AC-In. Use this mode when returning the set to the 
customer after repair.
 • 
Procedure:
  
1. 
Press 
[
I/1 STANDBY
] button to turn on the system.
 
  2. 
Select CD function.
 
 3.  Press [ENTER] button and [MUSIC] button 
simultaneously for 3 seconds. The system turns off 
automatically.  
  
4. 
message 
 
   
“MECHA LOCK” is displayed on the fl uorescent 
indicator tube and the CD ship mode is set.
       
HCD-GPX5G/GPX7G/GPX8G
20
[CD SHIP MODE (WITHOUT MEMORY CLEAR)]
 
•  This mode moves the optical pick-up to the position du-
rable to vibration. Use this mode when returning the set to 
the customer after repair.
 • 
Procedure:
  
1. 
Press 
[
I/1 STANDBY
] button to turn on the system.
 
  2. 
Select CD function.
 
  3. 
Press [BASS BAZUCA] button and [
I/1 STANDBY
button simultaneously. The system turns off 
  
 
automatically.
  
4. 
message
 
   
“MECHA LOCK” is displayed on the fl uorescent 
indicator tube and the CD ship mode is set.
[CD TRAY LOCK MODE]
 
•  This mode let you lock the disc tray. When this mode is ac-
tivated, the disc tray will not open when [
Z
 OPEN/CLOSE] 
button or [EX-CHANGE] button is pressed. The message 
“LOCKED” will be displayed on the fl uorescent indicator 
tube. This mode only applied when there is disc(s) on the 
tray.
 • 
Procedure:
  
1. 
Press 
[
I/1 STANDBY
] button to turn on the system.
 
  2. 
Select CD function.
  
3. 
Press 
[
x
] button and [ENTER] button simultane-
ously and hold down until “LOCKED” or “UN-
LOCKED” displayed on the fl uorescent  indicator 
tube (around 5 seconds).
[FACTORY PRESET]
 
•  This mode is use to load all the factory use preset frequen-
cies into FM 1-FM 20 and AM 1-AM 10. Originally, fre-
quency of FM 1-FM 20 and AM 1-AM10 are set to the 
minimum frequency.
 • 
Procedure:
  
1. 
Press 
[
I/1 STANDBY
] button to turn on the system.
 
  2.  Press [CD/DISC SKIP] button and [AUDIO IN] 
button simultaneously and hold for 3 seconds, 
message “FACTORY” appears on the fl uorescent 
indicator tube. The function is changed to TUNER 
automatically.
[CDM AGING MODE]
 
•  This mode is used to display the total count of meter 
pointer touch initial switch and max switch.
 • 
Procedure:
  
1. 
Press 
[
I/1 STANDBY
] button to turn on the system.
 
  2. 
Select CD function and All DISC play mode.
 
  3. 
Put discs on all trays and close the tray.
  
4. 
Press 
[
+
 / 
] button and [
x
] button simultane-
ously for 3 seconds.
 5. 
The 
fl uorescent indicator tube displays Aging 
Display “AG xxxx/yyyy”. 
 
   
“xxxx” represents the error counter
 
   
(Maximum Value of “xxxx” = 9999)
 
   
“yyyyy” represents the cycle counter
 
   
(Maximum Value of “yyyy” = 9999)
 
6. 
Press [<<] or [>>] to search for Aging History 
Error Display.
  
 
The 
fl uorescent indicator tube displays 
  
 
“Mx 
E1E2E3E4”. 
 
   
x: error history number
 
   
E1: Loading sequence JCP high
 
   
E2: Loading sequence JCP low
 
   
E3: Loading operation JCP
 
   
E4: Cam position operation JCP
 
7. 
Press [ENTER] to Aging Display
 
•  To release from Meter Aging Mode.
 
 
To release from this mode, press [
I/1 STANDBY
] button or 
perform COLD RESET operation.
[HISTORY MODE]
 
•  This mode is used to check important data stored in the 
system when PROTECTOR happen.
 • 
Procedure:
 
  1. 
During demo mode, press [
u
] button and [BASS 
BAZUCA] for 5 seconds to mode in to history 
mode.
 
  2.  Press the [TUNING +] or [TUNING -] button to 
check history data stored
Item
Display
Protector Count
P
R
O
C
O
U
N
T
 
 
Protector Type
P
R
O
T
Y
P
E
 
Single Power On Time T
1
 
H
M
Total Power On Time T
2
 
H
M
Input Function
F
U
N
C
 
Volume
V
O
L
      
Actual 
Attenuation
A
T
T
      
Low EQ Level
E
Q
 
L
O
W
 
 
 
Mid EQ Level
E
Q
 
M
I
D
 
 
 
High EQ Level
E
Q
 
H
I
G
H
 
 
VACS 
Level
V
A
C
S
      
AP  VACS Level
A
P
V
A
C
S
 
 
 
 
Subwoofer 
Setting
S
W
       
Surround 
Setting
S
U
R
R
     
DJ Effect Setting
D
J
 
 
Bass Bazuca Setting
B
A
Z
U
C
A
 
 
 
 
•  To release from History Mode.
 
 
To release from this mode, press [
I/1 STANDBY
] button. 
[PROTECT KIND CHECK TEST MODE]
 
•  This mode is used to check types of protect occurred during 
protector on.
 • 
Procedure:
 
  3.  During protection on, fl uorescent indicator tube 
shows blinking message “PROTECT  EXX”.
 
   
“EXX” – represent the error code.
  
4. 
Press 
[
u
] button & [
x
] button simultaneously.
 
 5.  Fluorescent indicator tube display will toggle 
between “PROTECT” message & protector kind 
message display.
 
   
Bellow table explains on protector kind.
Error Code
Protector Message Description
E01
"AMP OCP"
The over current condition to MOS-
FET occurs by defect of MOSFET or 
defect of PS output line.
E02
"MTK POWER"
No power supply to DMB mount
E03
"POWER SUPPLY" Defect of power supply circuit to AMP
E04
"AMPLIFIER"
Defect of AMP circuit
E06
"FAN BLOCK"
 Defect of DC FAN and DC FAN
driver circuit
 
•  To release from this mode.
  
Press 
[
u
] button & [
x
] button simultaneously again or 
unplug & re-plug in the power cord.
Page of 87