2-15. SENSOR BOARD
3 wire (flat type) (5 core)
(CN742)
4 two screws
(+BTTP
(M2.6))
5 motor assy, table (M741)
6 remove the two solderings of motor
7 MOTOR (TB) board
1 gear (stopper)
1 gear (stopper)
2
table
2-16. MOTOR (TB) BOARD
1 floating screw
(+PTPWH
M2.6)
4 floating screw
(+PTPWH
M2.6)
8 one screw
(+BTTP
(M2.6))
6 floating screw
(+PTPWH
M2.6)
7 gear (geneva)
2 tray
3 belt (table)
9 CN731
(3P)
0 SENSOR board
5 pulley (table)
HCD-GPX5G/GPX7G/GPX8G
18
2-17. MOTOR (LD) BOARD
1 belt (loading)
2 remove the two solderings of motor
4 motor assy, loading (M751)
5 MOTOR (LD) board
3 two screws
(+BTTP
(M2.6))
HCD-GPX5G/GPX7G/GPX8G
19
SECTION 3
TEST MODE
[PANEL TEST MODE]
• This mode is used to check the fl uorescent indicator tube,
LEDs, keys, [MASTER VOLUME] jog, model, destina-
tion and software version.
tion and software version.
•
Procedure:
1. Press [CD/DISC SKIP] button and [TUNER/BAND]
button simultaneously and hold 3 seconds.
2. All LEDs and segments in fl uorescent indicator tube are
lighted up.
3. When you want to enter to the software version display
mode, press [
+
/
] button. The model information
appears on the fl uorescent indicator tube.
• “GPX 3S” is shown for MHC-GPX5.
• “GPX 4” is shown for MHC-GPX7.
• “GPX 7S” is shown for MHC-GPX8.
Press
[
+
/
] button again to view the destination
information.
4. During the destination information display, press [
+
/
] button. Each time [
+
/
] button is pressed, the
fl uorescent indicator tube shows the version of each category
software in the following sequence: SC, MTK (DMB Board
fi rmware version), UI, PF, SYS, CD, CDMA, CDMB,
ST, TA, TAS, TM and return back to model information
display.
software in the following sequence: SC, MTK (DMB Board
fi rmware version), UI, PF, SYS, CD, CDMA, CDMB,
ST, TA, TAS, TM and return back to model information
display.
5.
When [OPTION] button is pressed while the version
numbers are being displayed except model and destination,
the date of the software creation appears. When [OPTION]
button is pressed again, the display returns to the software
version display.
the date of the software creation appears. When [OPTION]
button is pressed again, the display returns to the software
version display.
6.
Press
[
+
/ ↓] button, the key check mode is activated.
7. In the key check mode, the fl uorescent indicator tube
displays “K 0 V0”.
Each time a button is pressed, “K” value increases.
However, once a button has been pressed, it is no longer
taken into account.
“V” value increases in the manner of 0,1, 2, 3 ... if [MAS-
TER VOLUME] knob is turned clockwise, or it decreases
in the manner of 0, 9, 8,7 ... if [MASTER VOLUME] knob
is turned counterclockwise.
TER VOLUME] knob is turned clockwise, or it decreases
in the manner of 0, 9, 8,7 ... if [MASTER VOLUME] knob
is turned counterclockwise.
8. When [ENTER] button is pressed after all LEDs and
segments in fl uorescent indicator tube light up, alternate
segments in fl uorescent indicator tube and LEDs would
light up. If you press [ENTER] button again, another half
of alternate segments in fl uorescent indicator tube and
LEDs would light up. Pressing [ENTER] button again
would cause all segments in fl uorescent indicator tube and
LEDs light up.
segments in fl uorescent indicator tube and LEDs would
light up. If you press [ENTER] button again, another half
of alternate segments in fl uorescent indicator tube and
LEDs would light up. Pressing [ENTER] button again
would cause all segments in fl uorescent indicator tube and
LEDs light up.
9. To release from this mode, press three buttons in the same
manner as step 1, or disconnect the power cord.
[COMMON TEST MODE]
• This mode is used to check operations of the Amplifi er
section.
•
Procedure:
• To enter Common Test Mode
1. Press [USB/USB SELECT] button and [BASS BAZUCA]
button simultaneously and hold for 3 seconds.
2. The function is changed to TV and the volume is changed
to VOLUME MIN.
•
Check
of
Amplifi er
1. Press [MUSIC] button repeatedly until a message “GEQ
MAX” appears on the fl uorescent indicator tube. GEQ in-
creases to its maximum.
creases to its maximum.
2. Press [MUSIC] button repeatedly until a message “GEQ
MIN” appears on the fl uorescent indicator tube. GEQ
decreases to its minimum.
decreases to its minimum.
3. Press [MUSIC] button repeatedly until a message “GEQ
FLAT” appears on the fl uorescent indicator tube. GEQ is
set to fl at.
set to fl at.
4. When the [MASTER VOLUME] knob is turned clockwise
even slightly, the sound volume increases to its maximum
and a message “VOLUME MAX” appears on the fl uores-
cent indicator tube.
and a message “VOLUME MAX” appears on the fl uores-
cent indicator tube.
5. When the [MASTER VOLUME] knob is turned counter-
clockwise even slightly, the sound volume decreases to its
minimum and a message “VOLUME MIN” appears on the
fl uorescent indicator tube.
minimum and a message “VOLUME MIN” appears on the
fl uorescent indicator tube.
• To release from Common Test mode
1. To release from this mode, press [
I/1 STANDBY
] button.
2. The cold reset is enforced at the same time.
[USER RESET]
• The user reset clears all data including preset data stored
in the data fl ash to initial conditions exclude history mode
data
data
•
Procedure:
1.
Press
[
I/1 STANDBY
] button to turn on the system.
2.
Press [
x
] button and [
I/1 STANDBY
] button simultane
ously for 3 seconds.
3.“RESET” appears on the fl uorescent indicator tube.
After
After
that,
the
fl uorescent indicator tube becomes blank
for a while, and the system is reset.
[COLD RESET]
• The cold reset clears all data including preset data stored in
the data fl ash to initial conditions. Execute this mode when
returning the set to the customer.
returning the set to the customer.
•
Procedure:
1.
Press
[
I/1 STANDBY
] button to turn on the system.
2.
Press [ENTER] button and [GAME] button
simultaneously for 3 seconds.
3.
“COLD RESET” appears on the fl uorescent
indicator tube. After that, the fl uorescent indicator
tube becomes blank for a while, and the system is
reset.
[TUNER STEP CHANGE]
• The step interval of AM channels can be toggled between
9 kHz and 10 kHz. This mode is not available for Saudi
Arabian, European and Russian models.
Arabian, European and Russian models.
•
Procedure:
1.
Press
[
I/1 STANDBY
] button to turn on the system.
2.
Press [TUNER/BAND] button repeatedly to select
the
“AM”.
3.
Press
[
I/1 STANDBY
] button to turn off the system.
4.
Press [LED EFFECT] button and [
I/1 STANDBY
]
button simultaneously. The system turns on
automatically. The message “AM 9K STEP”
or “AM 10K STEP” appears on the fl uorescent
indicator tube and thus the channel step is changed.
[CD SHIP MODE (WITH MEMORY CLEAR)]
• This mode moves the optical pick-up to the position
durable to vibration and clears all data including preset
data stored in the EEPROM to initial conditions during the
next AC-In. Use this mode when returning the set to the
customer after repair.
data stored in the EEPROM to initial conditions during the
next AC-In. Use this mode when returning the set to the
customer after repair.
•
Procedure:
1.
Press
[
I/1 STANDBY
] button to turn on the system.
2.
Select CD function.
3. Press [ENTER] button and [MUSIC] button
simultaneously for 3 seconds. The system turns off
automatically.
automatically.
4.
A
message
“MECHA LOCK” is displayed on the fl uorescent
indicator tube and the CD ship mode is set.
indicator tube and the CD ship mode is set.
HCD-GPX5G/GPX7G/GPX8G
20
[CD SHIP MODE (WITHOUT MEMORY CLEAR)]
• This mode moves the optical pick-up to the position du-
rable to vibration. Use this mode when returning the set to
the customer after repair.
the customer after repair.
•
Procedure:
1.
Press
[
I/1 STANDBY
] button to turn on the system.
2.
Select CD function.
3.
Press [BASS BAZUCA] button and [
I/1 STANDBY
]
button simultaneously. The system turns off
automatically.
4.
A
message
“MECHA LOCK” is displayed on the fl uorescent
indicator tube and the CD ship mode is set.
indicator tube and the CD ship mode is set.
[CD TRAY LOCK MODE]
• This mode let you lock the disc tray. When this mode is ac-
tivated, the disc tray will not open when [
Z
OPEN/CLOSE]
button or [EX-CHANGE] button is pressed. The message
“LOCKED” will be displayed on the fl uorescent indicator
tube. This mode only applied when there is disc(s) on the
tray.
“LOCKED” will be displayed on the fl uorescent indicator
tube. This mode only applied when there is disc(s) on the
tray.
•
Procedure:
1.
Press
[
I/1 STANDBY
] button to turn on the system.
2.
Select CD function.
3.
Press
[
x
] button and [ENTER] button simultane-
ously and hold down until “LOCKED” or “UN-
LOCKED” displayed on the fl uorescent indicator
tube (around 5 seconds).
LOCKED” displayed on the fl uorescent indicator
tube (around 5 seconds).
[FACTORY PRESET]
• This mode is use to load all the factory use preset frequen-
cies into FM 1-FM 20 and AM 1-AM 10. Originally, fre-
quency of FM 1-FM 20 and AM 1-AM10 are set to the
minimum frequency.
quency of FM 1-FM 20 and AM 1-AM10 are set to the
minimum frequency.
•
Procedure:
1.
Press
[
I/1 STANDBY
] button to turn on the system.
2. Press [CD/DISC SKIP] button and [AUDIO IN]
button simultaneously and hold for 3 seconds,
message “FACTORY” appears on the fl uorescent
indicator tube. The function is changed to TUNER
automatically.
message “FACTORY” appears on the fl uorescent
indicator tube. The function is changed to TUNER
automatically.
[CDM AGING MODE]
• This mode is used to display the total count of meter
pointer touch initial switch and max switch.
•
Procedure:
1.
Press
[
I/1 STANDBY
] button to turn on the system.
2.
Select CD function and All DISC play mode.
3.
Put discs on all trays and close the tray.
4.
Press
[
+
/
] button and [
x
] button simultane-
ously for 3 seconds.
5.
The
fl uorescent indicator tube displays Aging
Display “AG xxxx/yyyy”.
“xxxx” represents the error counter
(Maximum Value of “xxxx” = 9999)
“yyyyy” represents the cycle counter
(Maximum Value of “yyyy” = 9999)
6.
Press [<<] or [>>] to search for Aging History
Error Display.
Error Display.
The
fl uorescent indicator tube displays
“Mx
E1E2E3E4”.
x: error history number
E1: Loading sequence JCP high
E2: Loading sequence JCP low
E3: Loading operation JCP
E4: Cam position operation JCP
7.
Press [ENTER] to Aging Display
• To release from Meter Aging Mode.
To release from this mode, press [
I/1 STANDBY
] button or
perform COLD RESET operation.
[HISTORY MODE]
• This mode is used to check important data stored in the
system when PROTECTOR happen.
•
Procedure:
1.
During demo mode, press [
u
] button and [BASS
BAZUCA] for 5 seconds to mode in to history
mode.
mode.
2. Press the [TUNING +] or [TUNING -] button to
check history data stored
Item
Display
Protector Count
P
R
O
C
O
U
N
T
Protector Type
P
R
O
T
Y
P
E
Single Power On Time T
1
H
M
Total Power On Time T
2
H
M
Input Function
F
U
N
C
Volume
V
O
L
Actual
Attenuation
A
T
T
Low EQ Level
E
Q
L
O
W
Mid EQ Level
E
Q
M
I
D
High EQ Level
E
Q
H
I
G
H
VACS
Level
V
A
C
S
AP VACS Level
A
P
V
A
C
S
Subwoofer
Setting
S
W
Surround
Setting
S
U
R
R
DJ Effect Setting
D
J
Bass Bazuca Setting
B
A
Z
U
C
A
• To release from History Mode.
To release from this mode, press [
I/1 STANDBY
] button.
[PROTECT KIND CHECK TEST MODE]
• This mode is used to check types of protect occurred during
protector on.
•
Procedure:
3. During protection on, fl uorescent indicator tube
shows blinking message “PROTECT EXX”.
“EXX” – represent the error code.
4.
Press
[
u
] button & [
x
] button simultaneously.
5. Fluorescent indicator tube display will toggle
between “PROTECT” message & protector kind
message display.
message display.
Bellow table explains on protector kind.
Error Code
Protector Message Description
E01
"AMP OCP"
The over current condition to MOS-
FET occurs by defect of MOSFET or
defect of PS output line.
FET occurs by defect of MOSFET or
defect of PS output line.
E02
"MTK POWER"
No power supply to DMB mount
E03
"POWER SUPPLY" Defect of power supply circuit to AMP
E04
"AMPLIFIER"
Defect of AMP circuit
E06
"FAN BLOCK"
Defect of DC FAN and DC FAN
driver circuit
driver circuit
• To release from this mode.
Press
[
u
] button & [
x
] button simultaneously again or
unplug & re-plug in the power cord.
Click on the first or last page to see other HCD-GPX5G / HCD-GPX7G / HCD-GPX8G service manuals if exist.