DOWNLOAD Sony HCD-GN70V / MHC-GN70V Service Manual ↓ Size: 5.23 MB | Pages: 79 in PDF or view online for FREE

Model
HCD-GN70V MHC-GN70V
Pages
79
Size
5.23 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
hcd-gn70v-mhc-gn70v.pdf
Date

Sony HCD-GN70V / MHC-GN70V Service Manual ▷ View online

21
HCD-GN70V
SECTION 5
MECHANICAL ADJUSTMENTS
SECTION 6
ELECTRICAL ADJUSTMENTS
Precaution
1. Clean the following parts with a denatured alcohol-moistened
swab:
record/playback heads
pinch rollers
erase head rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head
demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
Torque Measurement
3.06 N • m to 6.96 N • m
31 to 71 g • cm
(0.43 – 0.98 oz • inch)
0.19 N • m to 0.58 N • m
2 to 6 g • cm
(0.02 – 0.08 oz • inch)
3.06 N • m to 6.96 N • m
31 to 71 g • cm
(0.43 – 0.98 oz • inch)
0.19 N • m to 0.58 N • m
2 to 6 g • cm
(0.02 – 0.08 oz • inch)
6.96 N • m to 14.02 N • m
71 to 143 g • cm
(0.98 – 1.99 oz • inch)
9.80 N • m
100 g or more
(3.53 oz or more)
9.80 N • m
100 g or more
(3.53 oz or more)
Mode
Torque meter
CQ-102C
CQ-102C
CQ-102RC
CQ-102RC
CQ-201B
CQ-403A
CQ-403R
Meter reading
FWD
FWD
back tension
REV
REV
back tension
FF/REW
FWD tension
REV tension
0 dB=0.775 V
DECK  SECTION
1. Demagnetize the record/playback head with a head
demagnetizer.
2. Do not use a magnetized screwdriver for the adjustments.
3. After the adjustments, apply suitable locking compound to the
parts adjust.
4. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
5. The adjustments should be performed in the order given in this
service manual.  (As a general rule, playback circuit adjustment
should be completed before performing recording circuit
adjustment.)
6. The adjustments should be performed for both L-CH and R-
CH.
7. Switches and controls should be set as follows unless otherwise
specified.
• Test Tape
RECORD/PLAYBACK  HEAD  AZIMUTH  ADJUST-
MENT
DECK A      DECK B
Note:  Perform this adjustments for both decks
Procedure:
1. Mode:  Playback
Tape
Signal
Used for
P-4-A100
10 kHz, –10 dB
Azimuth Adjustment
WS-48B
3kHz, 0 dB
Tape Speed Adjustment
set
MAIN board
CN301
Pin 
1
 (L-CH)
Pin 
3
 (R-CH)
MAIN board
CN301
Pin 
2
 (GND)
+
level meter
test tape
P-4-A100
(10 kHz, –10 dB)
22
HCD-GN70V
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
3. Mode:  Playback
4. After the adjustments, apply suitable locking compound to the
pats adjusted.
Adjustment Location: Playback Head (Deck A).
Record/Playback/Erase Head (Deck B).
Screw
position
L-CH
peak
within
1dB
Output
level
L-CH
peak
R-CH
peak
within
1dB
Screw
position
R-CH
peak
MAIN
board
CN301
set
test tape
P-4-A100
(10 kHz, –10 dB)
pin 
3
oscilloscope
L-CH
R-CH
V
H
waveform of oscilloscope
in phase 45
°
90
°
135
°
180
°
good
wrong
pin 
2
pin 
1
L
R
forward
reverse
Tape Speed Adjustment
   DECK B
Procedure:
Mode: Playback
set
MAIN board
AUDIO OUT jack (J730)
L-CH, R-CH
+
frequency counter
test tape
WS-48B
(3 kHz, 0 dB)
1. Insert the WS-48B into the deck B.
2. Press the   H  button on the deck B.
3. Adjust the tape speed adjustment control inside motor so that
frequency counter reads 3,000 
± 90Hz.
Sample value of wow and flutter W.RMS (JIS) less than 0.3%
WS-48B
Adjustment Location:
Tape speed Adjustment
Tape speed adjustment
control inside motor
– MAIN BOARD (Component Side) –
CN301
IC301
3
1
23
HCD-GN70V
 CD SECTION
Note :
1. CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.
2. Use LUV-P01 (4-999-032-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M
Ω impedance.
4. Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the
following checks.
S-Curve Check
BD board
Oscilloscope
TP(FE)
TP(DVC)
Procedure :
1. Connect oscilloscope to TP (FE).
2. Connect between TP (FE) and TP (DVC (   1.65 V)) by lead
wire.
3. Press the  \/1  button to turn the power ON.
4. Load a disc (LUV-P01) and actuate the focus search. (In conse-
quence of open and close the disc tray, actuate the focus search)
5. Confirm that the oscilloscope waveform (S-curve) is symmetri-
cal between A and B. And confirm peak to peak level within 2
±0.5 Vp-p.
symmetry
S-curve waveform
within 4 
±
1Vp-p
A
B
6. After check, remove the lead wire connected in step 2.
Note : • Try to measure several times to make sure than the ratio
  of A : B or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
  brightness to obtain best waveform.
RF Level Check
Procedure :
1. Connect oscilloscope to TP (RFDC) and TP (RFAC).
2. Press the  \/1  button to turn the power ON.
3. Load a disc (LUV-P01) and playback.
4. Confirm that oscilloscope waveform is clear and check RF
signal level is correct or not.
Note: Clear RF signal waveform means that the shape “◊” can be
       clearly distinguished at the center of the waveform.
VOLT/DIV : 200mV
TIME/DIV : 500ns
level : 1.45 
±
 0.3Vp-p
E-F Balance (1 Track jump) Check
TP(TE)
TP(DVC)
BD board
oscilloscope
Procedure:
1. Connect oscilloscope to TP (TE) and TP (DVC) on BD board.
2. Press the  \/1  button to turn the power ON.
3. Load a disc (LUV-P01) and playback the number nine track.
4. Press the  bB  button. (Becomes the 1track jump mode.)
5. Confirm that the level B and A (DC voltage) on the oscillo-
scope waveform.
B=1.3 
±
 0.6Vp-p
symmetry
A (DC voltage)
center of
waveform
B
0V
Specified level:     
× 100=less than – 22%
B
A
Checking Location:
[BD BOARD] (SIDE B)
DVC
RFDC
RFAC
TE
FE
SE
DVC
TP(RFDC)
TP(RFAC)
BD board
oscilloscope
24
HCD-GN70V
VIDEO SECTION
Note :
1. VIDEO board is basically designed to operate without adjust-
ment. Therefore, check each item in order given.
2. Use HLV-402 (8-909-870-00) unless otherwise indicated.
3. Use an oscilloscope with more than 10M
Ω impedance.
4. Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the
following checks.
Video Level Check (VIDEO BOARD)
Purpose
This adjustment is made to satisfy the NTSC standard, and if not
adjusted correctly, the brightness will be too large or small.
Procedure:
1. Connect oscilloscope to VIDEO output.
2. Load a disc HLV-402 (8-909-870-00) playback.
3. Check that the video level is 1.0 
± 0.1 Vp-p.
J721
VIDEO OUTPUT
75 
Oscilloscope
set
1.0 ± 0.1 Vp-p
(WHITE 100%)
Page of 79
Display

Click on the first or last page to see other HCD-GN70V / MHC-GN70V service manuals if exist.