HCD-GN1300D
21
SECTION  4
MECHANICAL  ADJUSTMENTS
Precaution
1.  Clean the following parts with a denatured alcohol-moistened 
swab:
 
record/playback heads 
pinch rollers
 
erase head 
rubber belts
 capstan 
idlers
2.  Demagnetize the record/playback head with a head demagne-
tizer.
3.  Do not use a magnetized screwdriver for the adjustments.
4.  After the adjustments, apply suitable locking compound to the 
parts adjusted.
5.  The adjustments should be performed with the rated power 
supply voltage unless otherwise noted.
Torque Measurement
Mode
Torque meter
Meter reading
FWD
CQ-102C
2.9m N • m to 6.9m N • m
 30 to 70 g • cm 
(0.42 – 0.97 oz • inch)
FWD
back tension
CQ-102C
0.15m N • m to 0.59m N • m 
2 to 6 g • cm 
(0.03 – 0.08 oz • inch)
REV
CQ-102RC
2.9m N • m to 6.9m N • m
 30 to 70 g • cm 
(0.42 – 0.97 oz • inch)
REV
back tension
CQ-102RC
0.15m N • m to 0.59m N • m 
2 to 6 g • cm 
(0.03 – 0.08 oz • inch)
FF/REW
CQ-201B
4.8m N • m to 16.7m N • m 
49 to 170 g • cm
 (0.68 – 2.36 oz • inch)
HCD-GN1300D
22
SECTION  5
ELECTRICAL  ADJUSTMENTS
[FM Tune Level Check]
Procedure:
1.  Turn the power on.
2.  Input the following signal from Signal Generator to FM 
antenna input directly.
  
*  Carrier Freq  : A = 87.5 MHz, B = 98 MHz, C = 108 MHz
 
Deviation     : 75 kHz
 
Modulation   : 1 kHz
 
ANT input    : 35 dBu (EMF)
 
Note:  Please use 75 ohm “coaxial cable” to connect SG and the set. You 
cannot use video cable for checking.
 
Please use SG whose output impedance is 75 ohm. 
  
3.  Set to FM tuner function and tune A, B and C signals.
4. Confi rm “TUNED” is lit on the display for A, B and C 
signals.
  
The mark of “TUNED” means “The selected station signal is 
received in good condition.”
TUNER SECTION
FM signal generator
OUT (75 7)
SET
DECK SECTION
Tape
Signal
Used for
P-4-A100
10 kHz, –10 dB
Azimuth Adjustment
0 dB=0.775V
1.   Demagnetize the record/playback head with a head demagne-
tizer.
2.   Do not use a magnetized screwdriver for the adjustments.
3.   After the adjustments, apply suitable locking compound to the 
parts adjusted.
4.   The adjustments should be performed with the rated power 
supply voltage unless otherwise noted.
5.   The adjustments should be performed in the order given in this 
service manual. (As a general rule, playback circuit adjustment 
should be completed before performing recording circuit ad-
justment.)
6.  The adjustments should be performed for both L-CH and 
RCH.
7.   Switches and controls should be set as follows unless other-
wise specifi ed.
• Test Tape
RECORD/PLAYBACK  HEAD  AZIMUTH  ADJUSTMENT
Procedure:
1.  Mode:  Playback
set
Audio Out Jack
at Back Panel
(White-L-CH)
(Red-R-CH)
Chassis GND
+
level meter
test tape
P-4-A100
(10 kHz, –10 dB)
2.  Turn the adjustment screw and check output peaks. If the 
peaks do not match for L-CH and R-CH, turn the adjustment 
screw so that outouts match within 1dB of peak.
DECK
L-CH
peak
Output
level
within
1dB
within
1dB
Screw
position
R-CH
peak
R-CH
peak
L-CH
peak
Screw
position
HCD-GN1300D
23
DVD SECTION
3.  Mode:  Playback
set
Audio Out Jack
at Back Panel
test tape
P-4-A100
(10 kHz, –10 dB)
Chassis-GND
oscilloscope
L-CH
R-CH
V
H
waveform of oscilloscope
in phase 45
°
90
° 135° 180°
good
wrong
Red-R-CH
White-L-CH
L
R
4.  After the adjustments, apply suitable locking compound to the 
pats adjusted.
Adjustment Location: Record/Playback/Erase Head
[TEST DISC LIST]
Use the following test disc on test mode.
• CD: 
YEDS-18 (PART No. 3-702-101-01)
  
 
or
   
PATD-012 (PART No. 4-225-203-01)
• DVD (SL) 
  NTSC 
HLX-503 (PART No. J-6090-069-A)
  
 
or
   
HLX-504 (PART No. J-6090-088-A)
  PAL 
HLX-506 (PART No. J-6090-077-A)
• DVD (DL)
  NTSC 
HLX-501 (PART No. J-6090-071-A)
  
 
or
   
HLX-505 (PART No. J-6090-089-A)
  PAL 
HLX-507 (PART No. J-6090-078-A)
Note: When the BASE UNIT is replaced, perform the Execute  
 IOP measurement 
 
(Refer to page 18).
[RFMON Level Check]
Connection:
+
CN105 pin  (RFMON)
CN105 pin  (GND)
oscilloscope 
DMB18 board
Procedure:
1.  Connect an oscilloscope to CN105 pin 6 (RFMON) and CN105 
pin 3 (GND) on the DMB18 board.
2.  Turn the power on.
3.  Set the test disc (DVD: HLX-503 (NTSC) or HLX-504 (PAL), 
CD: YEDS-18) on the tray and press 
C#
 button to play-
back.
4. Confi rm that oscilloscope waveform is clear and check RF-
MON signal level is correct or not.
Note:  A clear RFMON signal waveform means that the shape “◊” 
can be clearly distinguished at the center of the waveform.
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
RFMON signal waveform
level: 0.58 to 1.23 Vp-p (DVDSL)
          0.57 to 1.1 Vp-p (CD)
reverse
forward
HCD-GN1300D
24
Checking Location: DMB18 board (Side A)
IC102
IC101
IC104
IC201
CN105
CN109
DMB18 BOARD (SIDE A)
CN105 pin  (GND)
CN105 pin  (RFMON)
1
6
Page of 104
Display