HCD-ESX6/ESX8/ESX9
13
2-8.  SERVICE OPTICAL DEVICE, WIRE (FLAT TYPE)
Note 1 : Before disconnecting the wire (fl at type) (24 core) of optical pick-up block, solder the short-land.
Under the guide
Under the guide
(Fold area)
‡,QVWDOODWLRQRIZLUHIODWW\SHFRUHDQGZLUHIODWW\SHFRUH
Note: This illustration sees the loading assy (MB) from bottom side.
1 wire (flat type) (24 core)
2 Through the hole
3 Through the hole
4
terminal face
loading assy (MB)
7 wire (flat type)
 (24 
core)
6 holder, FFC
5 three claws
5 two claws
0 wire (flat type)
 (5 
core)
8 core, ferrite
9 tape
(
 
 
8 four insulator screws 
7 connector
qa insulator
6 belt
3 Insert the thin 
 
wire (clip etc.).
5 tray
qs service,
 optical 
device
qa insulator
qa insulator
qg
ql wire (flat type) 
 (24 
core)
qj core, ferrite
six claws
4
9
0
2 chuck holder assy (MB)
2 Solder the short-land.
qf wire (flat type)
 (5 
core)
– Bottom view –
loading assy (MB)
qd loading base
 assy
qk holder, FFC
qh tape
Note 2:  When assembling the optical pick-up block,
 
remove the solder of short-land after
 
connecting the wire (flat type) (24 core).  
(E93)
(E93)
HCD-ESX6/ESX8/ESX9
14
SECTION  3
ESX  TEST  MODE
[PANEL TEST MODE]
  This mode is used to check the liquid crystal display, LEDs, 
keys, [VOLUME] jog, model, destination and software 
version.
Procedure:
1.  Press [FUNCTION] button and [BASS BAZUCA] button 
simultaneously and hold 3 seconds.
2.  All LEDs and segments of liquid crystal display will light up.
3.  In the Panel Test Mode, when you want to enter to the 
software version display mode, press [+] button. The model 
information appears on the fl uorescent indicator tube.
 
• 
“ESX0” is shown for MHC-ESX6.
 
• 
“ESX1” is shown for MHC-ESX8.
 
• 
“ESX2” is shown for MHC-ESX9.
 Press 
[+] button again to view the destination information.
4.  During the destination information display, press [+] 
button. Each time [+]  button  is  pressed,  the  fl uorescent 
indicator tube shows the version of each category software 
in the following sequence: SC, MTK, OPU, UI, PF, SYS, CD, 
CMA, CMB, ST, TA, TAS, TM and return back to model 
information display.
5.  When [FUNCTION] button is pressed while the version 
numbers are being displayed except model and destination, 
the date of the software creation appears. When [FUNCTION] 
button is pressed again, the display returns to the software 
version display.
6.  Press [–] button, the key check mode is activated.
7.  In the key check mode, the liquid crystal display will displays 
“K 0    V0”.
 
Each time a button is pressed, “K” value increases. However, 
once  a  button  has  been  pressed,  it  is  no  longer  taken  into 
account.
 
“V” value increases in the manner of 0, 1, 2, 3 ... if [MASTER 
VOLUME] knob is turned clockwise, or it decreases in the 
manner of 0, 9, 8, 7 ... if [MASTER VOLUME] knob is turned 
counterclockwise.
8. When [] button is pressed after all LEDs and segments in 
liquid crystal display light up, alternate segments in liquid 
crystal display and LEDs would light up. If you press [] 
button  again,  another  half  of  alternate  segments  in  liquid 
crystal display and LEDs would light up. Pressing [] button 
again would cause all segments in liquid crystal display and 
LEDs light up. Pressing [] button again would turn off all 
segments in fl uorescent indicator tube and all LEDs.
9.  To release from this mode, press the buttons in the same 
manner as step 1, or disconnect the power cord.
[USER RESET]
  The user reset clears all data including preset data stored in 
the data fl ash to initial conditions exclude history mode data.
Procedure:
1. Press 
[&/1] button to turn on the system.
2.  Press [FUNCTION] button and [&/1] button simultaneously 
for 3 seconds.
3.  “RESET” appears on the liquid crystal display. After that, 
the liquid crystal display becomes blank for a while, and the 
system is reset.
[COLD RESET]
  The cold reset clears all data including preset data stored in 
the data fl ash to initial conditions included history mode data. 
Execute this mode when returning the set to the customer.
Procedure:
1. Press 
[&/1] button to turn on the system.
2.  Press [ENTER] button and [&/1] button simultaneously for 3 
seconds.
3.  “COLD RST” appears on the liquid crystal display. After 
that, the liquid crystal display becomes blank for a while, and 
the system is reset.
[CD SHIP MODE (WITH MEMORY CLEAR)]
  This mode moves the optical pick-up to the position durable 
to vibration and clears all data including preset data stored in 
the data fl ash to initial conditions during the next AC-In. Use 
this mode when returning the set to the customer after repair.
Procedure:
1. Press 
[\/1] button to turn on the system.
2.  Press [FUNCTION] button to select CD function.
3.  Press [OPTIONS] button and [TUNING –] button simultaneously
for 3 seconds. The system turns off automatically.
4.  A message “MECHA LOCK” is displayed on the liquid 
crystal display and the CD ship mode is set.
[CD TRAY LOCK MODE]
  This mode let you lock the disc tray. When this mode is 
activated,  the  disc  tray  will  not  open  when  [Z] button is 
pressed. The message “LOCKED” will be displayed on the 
liquid crystal display. This mode only applied when there is 
disc(s) on the tray.
Procedure:
1. Press 
[\/1] button to turn on the system.
2.  Press [FUNCTION] button to select CD function.
3. Press 
[] button and [REC TO USB] button simultaneously 
and hold down until “LOCKED” or “UNLOCKED” displayed 
on the liquid crystal display (around 5 seconds).
[CDM AGING MODE]
  This mode is used for CDM aging.
Procedure:
1. Press 
[\/1] button to turn on the system.
2.  Press [FUNCTION] button to select CD function.
3.  Open the disc tray, insert a disc and close the tray.
4.  Press [REC TO USB] button and [EQ +] button simultaneously 
for 3 seconds.
5. The liquid crystal display displays Aging Display 
“xxxxyyyy”.
 
“xxxx” represents the error counter
 
(Maximum Value of “xxxx” = 9999)
 
“yyyy” represents the cycle counter
 
(Maximum Value of “yyyy” = 9999)
6. Press [TUNING + M >]  or [TUNING –  .m] to 
search for Aging History Error Display.
 
The liquid crystal display displays “Mx” for 2 seconds to 
indicate selected history number. Then, liquid crystal display 
displays “E1E2E3E4”.
 
 
x: error history number
 
 
E1: Loading sequence JCP high
 
 
E2: Loading sequence JCP low
 
 
E3: Loading operation JCP
 
 
E4: Cam position operation JCP
7. Press 
[] to Aging Display
  To release from CDM Aging Mode.
To release from this mode, press [\/1] button or perform COLD 
RESET operation.
HCD-ESX6/ESX8/ESX9
15
[HISTORY MODE]
  This mode is used to check important data stored in the system 
when PROTECTOR happen.
Procedure:
1.  During demo mode, press [u] button and [ENTER] for 5 
seconds to mode in to history mode.
2.  Press the [TUNING + M >] or [TUNING  –  .m] 
button to check history data stored.
  To release from History Mode.
 
To release from this mode, press [\/1] button.
[PROTECT KIND CHECK TEST MODE]
  This mode is used to check types of protect occurred during 
protector on.
Procedure:
1.  During protection on, liquid crystal display shows blinking 
message “PROTECT EXX” where “EXX” represent the error 
code.
2. Press 
[u] button and [OPTIONS] button simultaneously.
3.  Liquid crystal display will toggle between “PROTECT” 
message and protector kind message display.
 
Below table explains on protector kind.
Error 
Code 
Protector Message
Description
E03
“AMP ERR”
Amplifi er Defect
E04
“DC 
DET”
DC different appears in 
SPEAKER terminal due to 
Amplifi er defect.
E06
“FANBLOCK”
Defect of DC FAN and DC 
FAN driver circuit
  To release from this mode:
 Press 
[u] button and [OPTIONS] button simultaneously 
again or unplug and re-plug in the power cord.
Display on liquid crystal display
Description
P
C
O
U
N
T
No of time protector happen (0 ~ 99)
P
T
Indication protector type (refer protector kind test mode)
Protector type
Protector Error Code
AMP
E03
DC
E04
FAN
E06
1
*h
*h
*h
*h
*h
*m
*m
Single Power On Time until protector happened
(0~99999 hours, 0~99Min)
2
*h
*h
*h
*h
*h
*m
*m
Total Power On Time [ no consider protector happen ]
(0~99999 hours, 0~99Min)
F
Input Function during protector happened
V
O
L
Volume setting (MIN / 1 - 50 / MAX)
A
T
T
Actual attenuation (-87 … 0)
L
O
W
Low EQ level (-6 … 0 … +6)
M
I
D
Mid EQ level (-6 … 0 … +6)
H
I
G
H
High EQ level (-6 … 0 … +6)
V
A
C
S
VACS level (0 ... 5)
A
P
V
A
C
S
AP VACS level (0 … 7)
S
U
R
R
Surround setting (OFF / ON)
B
A
S
S
Bass Bazuca setting (OFF / ON)
HCD-ESX6/ESX8/ESX9
16
CD  SECTION
Note:
1.  CD Block is basically constructed to operate without adjustment.
2.  Use YEDS-18 disc (Part No. 3-702-101-01) unless otherwise indicat-
ed.
3.  Use an oscilloscope with more than 10 MΩ impedance.
4.  Clean the object lens by an applicator with neutral detergent when the
 
signal level is low than specifi ed value with the following checks.
5.  Check the focus bias check when optical pick-up block is replaced.
FOCUS BIAS CHECK
Procedure :
1.  Connect the oscilloscope to CN507 pin 6 (RFMON) and
 
CN507 pin 3 (GND) on the MB board.
2.  Press the [
?/1
] button to turn the power on, and press the 
[FUNCTION] button to select CD function.
3.  Set disc (YEDS-18) and press the [u] button to playback.
4. Confi rm that oscilloscope waveform is as shown in the fi gure
 
below (eye pattern).
 
A good eye pattern means that the diamond shape (
) in the
center of the waveform can be clearly distinguished.
Checking Location:
-MB Board (Component Side)-
+
MB board
oscilloscope 
(DC range) 
CN507 pin 6 (RFMON)
CN507 pin 3 (GND)
VOLT/DIV: 200 mV 
TIME/DIV: 500 ns
level:
1.0 ± 0.25 Vp-p (CD)
SECTION  4
ELECTRICAL  CHECK
FM  AUTO  STOP  CHECK
Procedure:
1.  Turn the power on.
2.  Input the following signal from Signal Generator to FM an-
tenna input directly.
Carrier frequency : A = 87.5 MHz, B = 98 MHz, C = 108 MHz
Deviation 
: 75 kHz
Modulation 
: 1 kHz
ANT input 
: 35 dBu (EMF)
Note: Please use 75 ohm “coaxial cable” to connect SG and the set. You 
cannot use video cable for checking.
 
  Please use SG whose output impedance is 75 ohm.
3.  Set to FM tuner function and scan the input FM signal with 
automatic scanning.
4. Confi rm that input Frequency of A, B and C detected and auto-
matic scanning stops.
The stop of automatic scanning means “The station signal is re-
ceived in good condition”.
signal
generator
set
+
75 
:
TUNER  SECTION
0 dB = 1 
V
CN507
pin 3 (GND)
pin 6 (RFMON)