9
SECTION  4
MECHANICAL ADJUSTMENTS
PRECAUTION
1. Clean the following parts with a denatured alcohol-moistened
swab :
record/playback heads
pinch rollers
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head demagne-
tizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power sup-
ply voltage unless otherwise noted.
Torque Measurement
Mode
Torque meter
FWD
Meter reading
FWD
back tension
REV
CQ-102C
CQ-102C
CQ-102RC
CQ-102RC
CQ-201B
CQ-403A
CQ-403R
28 to 71g • cm
(0.39 – 0.99 oz • inch)
1 to 7g • cm
(0.01 – 0.10 oz • inch)
1 to 7g • cm
(0.01 – 0.10 oz • inch)
28 to 71g • cm
(0.39 – 0.99 oz • inch)
  DECK SECTION
0 dB=0.775V
1. Demagnetize the record/playback head with a head damagnetizer.
(Do not bring the head demagnetizer close to the erase head.)
2. Do not use a magnetized screwdriver for the adjustments.
3. After the adjustments, apply suitable locking compound to the
parts adjusted.
4. The adjustments should be performed with the rated power sup-
ply voltage unless otherwise noted.
5. The adjustments should be performed in the order given in this
service manual. (As a general rule, playback circuit adjustment
should be completed before performing recording circuit adjust-
ment.)
6. The adjustments should be performed for both L-CH and R-ch.
7. Switches and controls should be set as follows unless otherwise
specified.
SECTION  5
ELECTRICAL ADJUSTMENTS
Tape
P-4-A100
WS-48B
P-4-L300
Signal
10 kHz, –10 dB
3 kHz, 0 dB
315 Hz, 0 dB
Used for
Azimuth Adjustment
Tape Speed Adjustment
Level Adjustment
Record/Playback Head Azimuth Adjustment
Procedure :
1. Mode : Playback
REV
back tension
FF/REW
FWD tension
REV tension
100g or more
(3.53 oz or more)
100g or more
(3.53 oz or more)
56 to 122g • cm
(0.78 – 1.69 oz • inch)
+
set
MD OUT (JK301)
level meter
test tape
P-4-A100
(10kHz, –10dB)
10
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw so
that outputs match within 1 dB of peak.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
Adjustment Location :
Tape Speed Adjustment
Procedure :
Mode : Playback
3. Mode : Playback
1. Insert the WS-48B into the deck, and playback.
2. Adjust the Control at the bottom hole of the motor (M901) so
that the frequency counter reading becomes 3000 ± 90 Hz.
Adjustment Location : MOTOR (M901)
oscilloscope
MD OUT (JK301)
set
MD OUT (JK301)
test tape
P-4-A100
(10kHz, –10dB)
L
R
Waveform of oscilloscope
good
wrong
in phase
45 
°
90 
°
135 
°
180 
°
L-CH
peak
R-CH
peak
screw
position
output
level
within
1dB
L-CH
peak
R-CH
peak
screw
position
within 1dB
+
MD OUT (JK301)
set
frequency counter
test tape
WS-48B
(3kHz, 0dB)
 REV side
FWD side
Adjustment screw
Remove the front panel(B)
claw
claw
level meter
MD OUT (JK301)
set
test tape
P-4-L300
(315Hz, 0dB)
Deck is VR703 (L-CH) and VR704 (R-CH)
so that adjustment within the following adjustment level.
Adjustment level :
Playback level: 301.5 to 338.3 mV (–8.2 to –7.2 dB) level dif-
ference between the channels: within ±0.5 dB
Adjustment Location : TAPE PREAMP board
Sample Value of Wow and flutter
W.RMS (JIS) less than 0.3%
(test tape: WS-48B)
Playback Level Adjustment
Procedure :
Mode : Playback
Adjusting hole
11
2. Mode : Playback
2. Mode: Playback
Confirm playback the signal recorded in step 1 become adjustment
level as follows.
If these levels do not adjustment level, adjustment the VR701 (L-
CH) and VR702 (R-CH) on the TAPE PREAMP board to repeat
steps 1 and 2.
Adjustment level : Playback output of 10kHz level diffrence
against 315Hz reference should be ±0.5 dB.
Adjustment Location : TAPE PREAMP board
Record Level Adjustment
Procedure :
1. Mode: Record
Confirm playback the signal recorded in step 1 become adjustment
level as follows.
If these levels do not adjustment level, adjustment the VR705 (L-
CH) and VR706 (R-CH) on the TAPE PREAMP board to repeat
steps 1 and 2.
Adjustment level :
Playback level : 47.2 to 53.0 mV (–24.3 to –23.3 dB)
Adjustment Location : TAPE PREAMP board
Adjustment Location
[TAPE PREAMP BOARD] (Component Side)
Record Bias Adjustment
Procedure :
1. Mode : Record
level meter
MD OUT (JK301)
set
recorded
position
AF OSC
attenuator
600
set
MD IN (JK301)
1) 315Hz
2) 10kHz
blank tape
CS-123
50 mV (–23.8 dB)
}
AF OSC
attenuator
600
set
MD IN (JK301)
315Hz 50 mV (–23.8 dB)
blank tape
CS-123
level meter
MD OUT (JK301)
set
recorded
position
VR706
REC BIAS
R
VR705
REC BIAS
L
VR704
PB LEVEL
R
VR703
PB LEVEL
L
12
CD SECTION
Note:
1. CD Block is basically constructed to operate without adjustment.
Therefore, check each item in order given.
2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M
 impedance.
4. Clean the object lens by an applicator with neutral detergent when
the signal level is low than specified value with the following
checks.
S Curve Check
Procedure :
1. Connect the oscilloscope to test points TP (FE) and TP (VC).
2. Connect TP (FEI) and Ground, and TP (AGCCON) and Ground
of the BD board with lead wires.
3. Press the  
1/u  button to turn the set ON.
4. With the disc (YEDS-18) loaded, press the  
(  button and per-
form focus search. (Focus search will be performed in the same
way even while the disc table is pushed in and out.)
5. Check the symmetry and peak to peak level of the oscilloscope
waveform (S curve) at this time.
S-curve waveform
6. After check, remove the lead wire connected in step 2.
Note:
 • Try to measure several times to make sure than the ratio of
A : B or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the bright-
ness to obtain best waveform.
Checking Location : BD board
RF Level Check
Procedure :
1. Connect oscilloscope to test point TP (RF) and TP (VC) on BD
board.
2. Connect TP (AGCCON) and Ground of the BD board with lead
wires.
3. Press the  
1/u  button to turn the set ON.
4. Put disc (YEDS-18) in and playback 5track.
5. Confirm that oscilloscope waveform is clear and check RF sig-
nal level is correct or not.
6. After check, remove the lead wire connected in step 2.
oscilloscope
BD board
TP (FE)
TP (VC)
+
symmetry
A
B
Within 4 
±
 1 Vp-p
oscilloscope
BD board
TP (RF)
TP (VC)
+
VOLT/DIV : 200mV
TIME/DIV : 500ns
level : 1.45 
±
 0.3 Vp-p
0V
Center of the waveform
B
Symmetry
A (DC voitage)
level : 1.3 
±
 0.6 Vp-p
oscilloscope
BD board
TP (TE)
TP (VC)
+
Note:
Clear RF signal waveform means that the shape “
” can be
clearly distinguished at the center of the waveform.
RF signal waveform
Checking Location : BD board
E-F Balance (1 Track Jump) check
Procedure:
1. Connect oscilloscope to test point TP (TE) and TP (VC) on BD
board.
2. Press the  
1/u  button to turn the unit ON.
3. Put disc (YEDS-18) in to play the number five track.
4. Press the  
(  button.
5. Check the level B of the oscilloscope's waveform and the A (DC
voltage) of the center of the Traverse waveform.
Confirm the following:
• A/B x 100 = less then ± 22 (%)
• B = 1.3 ± 0.6 Vp-p
1 track jump waveform
Checking Location : BD board
Checking Location : BD board
[ BD BOARD ] — SIDE B —
IC102
TP
(VC)
IC101
IC103
TP
(RF)
TP
(FE)
TP
(FEI)
TP
(AGCCON)
TP
(TE)
Page of 47