DOWNLOAD Sony HCD-DX70 Service Manual ↓ Size: 9.53 MB | Pages: 71 in PDF or view online for FREE

Model
HCD-DX70
Pages
71
Size
9.53 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
hcd-dx70.pdf
Date

Sony HCD-DX70 Service Manual ▷ View online

13
HCD-DX70
[Aging Mode]
This mode can be used for operation check of CD section and tape deck section.
• If an error occurred:
The aging operation stops and display status.
• If no error occurs:
The aging operation continues repeatedly.
1.
Operating method of Aging Mode
Turn on the main power and select “CD” of the function.
1) Set a disc in DISC1 tray.  Select ALL DISC CONTINUE, and REPEAT OFF.
2) Load the tapes recording use into the decks A and B respectively.
3) Press three buttons x ,  ENTER ,  and
DISC SKIP/EX-CHANGE  simultaneously.
4) Aging operations of CD and tape are started at the same time.
5) To exit the aging mode, perform [MC Cold Reset].
3. Aging Mode in CD section
1) Display state
• No error occurs
Note:
[*][*][*][*] :  Number of aging operations
Error display
E
** s ## $$ %%
1 2 3 4 5
• When the buttons x ,  ENTER  and  DISC 1  are pressed simultaneously, number of time of the mechanism error and the NO DISC error
can be checked.
Display:
EMC**EDC**
**:
Number of times of error (Maximum three times)
EMC: Mechanism error
EDC: NO DISC error
• When aging operation is complete, be sure to perform the MC Cold Reset to reset the error history.
D: No disc error
01: FOCUS ERROR
02: GFS ERROR
03: SETUP ERROR
01: NO DISC judgment without chucking retry
02: NO DISC judgment after chucking retry
Status at the time of NO DISC judgment
(High order digits only)
1:
STOP
2:
SETUP
3:
TOC READ
4:
ACCESS
5:
PLAY BACK
6:
PAUSE
7:
MANUAL SEARCH (PLAY)
8:
MANUAL SEARCH (PAUSE)
AGING[*][*][*][*]
1
 
**
2
 s
3
 
##
4
 
$$
5
 
%%
M: Mechanism error
Don’t care
High order digits only
D: Stopped during closing due to problems other than mechanism.
E: Stopped during opening due to problems other than mechanism.
C: Stopped during chucking due to problems other than mechanism.
F: Stopped during EX-opening due to problems other than mechanism.
Emergency related errors (High order digits only)
1:
Stopped during chuck-up
2:
Stopped during chuck-down
3:
Time out by EX-OPEN
5:
Time out by EX-CLOSE
The error No. 00 indicates the newest error.  As the error No. increases, it means the older error.
When you want to retrieve the error history, press the  PLAY MODE  button in the case of mechanism error.
Or press the  REPEAT  button in the case of NO DISC error.
Display
14
HCD-DX70
2)  Operation during aging mode
In the aging mode, the program is executed in the following
sequence.
(1)
The disc tray opens and closes.
(2)
The mechanism accesses DISC 2 and makes an attempt to
read TOC.  However, since there are no discs, a message
“CD2 NO DISC” appears.
(3)
The mechanism accesses DISC 3 and a message “CD3 NO
DISC” appears.
(4)
The disc tray turns to select a disc1.
(5)
A disc is chucked.
(6)
TOC of disc is read.
(7)
The pickup accesses to the track 1, and  playing 2 seconds.
(8)
The pickup accesses to the last track, and playing 2 seconds.
(9)
Every time when an aging operation of step 1 to step 8 is
complete, the display “AGING[*][*][*][*]” value increases
as the number of aging operations is counted up.
(10) Returns to step 1.
3. Aging Mode in Tape Deck section
1) Display state
• No error occurs
Display action now
• Error occurred
Display action last time
2)  Operation during aging mode
In the aging mode, the program is executed in the following
sequence.
(1) Rewind is executed up to the top of tape A and B.
(2) A tape on FWD side is played for 2 minutes.
(3) FF is executed up to either made for 20 second or the end of
tape.
(4) A tape is reversed, and the tape on REV side is played for 2
minutes.
(5) Rewind is executed up to the top of tape.
(6) Returns to step 2, and repeat steps from 2 to 5.
[Function Change Mode]
* elect either VIDEO or MD of the external FUNCTION input.
Procedure:
1.
Turn on the power.
2.
Press the two buttons  ENTER  and  ?/1  at the same time.
The main power is turned on and the other function of the
previous function is selected and displayed.  “MD” or
“VIDEO”.
NO. Display action
Action contents
Final timing
1
TAPE A AG-1
Rewind the TAPE A, B
The top of tape
2
TAPE A AG-2
FWD play the TAPE A
2 minutes playing
3
TAPE A AG-3
F.F. the TAPE A
20 second FF or the end
of tape
4
TAPE A AG-4
REV play the TAPE A
2 minutes playing
5
TAPE A AG-5
Rewind the TAPE A
The top of tape
6
TAPE B AG-2
FWD play the TAPE B
2 minutes playing
7
TAPE B AG-3
F.F. the TAPE B
20 second FF or the end
of tape
8
TAPE B AG-4
REV play the TAPE B
2 minutes playing
9
TAPE B AG-5
Rewind the TAPE B
The top of tape
15
HCD-DX70
SECTION 4
MECHANICAL ADJUSTMENTS
SECTION 5
ELECTRICAL ADJUSTMENTS
0 dB=0.775 V
DECK  SECTION
1. Demagnetize the record/playback head with a head
demagnetizer.
2. Do not use a magnetized screwdriver for the adjustments.
3. After the adjustments, apply suitable locking compound to the
parts adjust.
4. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
5. The adjustments should be performed in the order given in this
service manual.  (As a general rule, playback circuit adjustment
should be completed before performing recording circuit
adjustment.)
6. The adjustments should be performed for both L-CH and R-
CH.
7. Switches and controls should be set as follows unless otherwise
specified.
• Test Tape
Record/Playback Head Azimuth Adjustment
Tape
Signal
Used for
P-4-A100
10 kHz, –10 dB
Azimuth Adjustment
WS-48B
3 kHz, 0 dB
Tape Speed Adjustment
P-4-L300
315 Hz, 0 dB
Level Adjustment
DECK A      DECK B
Note:  Perform this adjustments for both decks
Procedure:
1. Mode:  Playback
Precaution
1. Clean the following parts with a denatured alcohol-moistened
swab:
record/playback heads
pinch rollers
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head
demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
Torque Measurement
set
main board
CN301
Pin 
3 (L-CH)
Pin 
1 (R-CH)
main board
CN301
Pin 
2 (GND)
+
level meter
test tape
P-4-A100
(10 kHz, –10 dB)
3.06 N • m to 6.96 N • m
31 to 71 g • cm
(0.43 – 0.98 oz • inch)
0.19 N • m to 0.58 N • m
2 to 6 g • cm
(0.02 – 0.08 oz • inch)
3.06 N • m to 6.96 N • m
31 to 71 g • cm
(0.43 – 0.98 oz • inch)
0.19 N • m to 0.58 N • m
2 to 6 g • cm
(0.02 – 0.08 oz • inch)
6.96 N • m to 14.02 N • m
71 to 143 g • cm
(0.98 – 1.99 oz • inch)
9.80 N • m
100 g or more
(3.53 oz or more)
9.80 N • m
100 g or more
(3.53 oz or more)
Mode
Torque meter
CQ-102C
CQ-102C
CQ-102RC
CQ-102RC
CQ-201B
CQ-403A
CQ-403R
Meter reading
FWD
FWD
back tension
REV
REV
back tension
FF/REW
FWD tension
REV tension
16
HCD-DX70
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
3. Mode:  Playback
4. After the adjustments, apply suitable locking compound to the
pats adjusted.
Adjustment Location: Playback Head (Deck A).
Record/Playback/Erase Head (Deck B).
Tape Speed Adjustment
DECK B
Note: Start the Tape Speed adjustment as below after setting to the test
mode.
In the test mode, the tape speed is high during pressing the
 CD SYNC HI-DUB 
 button.
Procedure:
1. Turn the power switch on.
2. Press the x button,  ENTER  button and  DISC 3  button
simultaneously.
(The “TEST MODE” on the fluorescent indicator tube display
while in the test mode.)
To exit from the test mode, press the ?/1 button.
Mode:  Playback
1. Insert the WS-48B into the deck B.
2. Press the gG button on the deck B.
3. Press the  CD SYNC HI-DUB  button in playback mode.
Then at HIGH speed mode.
4. Adjust RV1001 on the LEAF SW board do that frequency
counter reads 6,000 ± 30 Hz.
5. Press the  CD SYNC HI-DUB  button.
Then back to NORMAL speed mode.
6. Adjust RV1002 on the LEAF SW board so that frequency
counter reads 3,000 ± 15 Hz.
Adjustment Location:  LEAF SW board
Playback level Adjustment
DECK A      DECK B
Procedure:
Mode:  Playback
Deck A is RV302 (L-CH), Deck B is RV303 (L-CH) so that
adjustment within adjustment level as follows.
Adjustment Level:
CN301 PB level:  334.4 to 748.7 mV (–7.3 to  –0.3 dB) level
difference between the channels:  within ±0.5 dB
Adjustment Location:  MAIN board
Sample Volue of Wow and Flutter: 0.3% or less W. RMS
(WS-48B)
Screw
position
L-CH
peak
within
1dB
Output
level
L-CH
peak
R-CH
peak
within
1dB
Screw
position
R-CH
peak
MAIN
board
CN301
set
test tape
P-4-A100
(10 kHz, –10 dB)
pin 1
oscilloscope
L-CH
R-CH
V
H
waveform of oscilloscope
in phase 45
° 90° 135° 180°
good
wrong
pin 2
pin 3
L
R
+
set
test tape
WS-48B 
(3 kHz, 0 dB)
main board
CN301 (Pin 
3 : 
L-CH)
(Pin 1 : 
R-CH)
frequency counter
+
set
test tape
P-4-L300J
(315 Hz, 0 dB)
main board
CN301 (Pin 
: L-CH)
level meter
forward
reverse
Page of 71
Display