17
HCD-DX60AV/RG70AV
2)  Operation during aging mode
In the aging mode, the program is executed in the following
sequence.
(1)
The disc tray opens and closes.
(2)
The mechanism accesses DISC 2 and makes an attempt to
read TOC.  However, since there are no discs, a message
“CD2 NO DISC” appears.
(3)
The mechanism accesses DISC 3 and a message “CD3 NO
DISC” appears.
(4)
The disc tray turns to select a disc1.
(5)
A disc is chucked.
(6)
TOC of disc is read.
(7)
The pickup accesses to the track 1, and  playing 2 seconds.
(8)
The pickup accesses to the last track, and playing 2 seconds.
(9)
Every time when an aging operation of step 1 to step 8 is
complete, the display “AGING[*][*][*][*]” value increases
as the number of aging operations is counted up.
(10) Returns to step 1.
3. Aging Mode in Tape Deck section
1) Display state
• No error occurs
Display action now
• Error occurred
Display action last time
2)  Operation during aging mode
In the aging mode, the program is executed in the following
sequence.
(1) Rewind is executed up to the top of tape A and B.
(2) A tape on FWD side is played for 2 minutes.
(3) FF is executed up to either made for 20 second or the end of
tape.
(4) A tape is reversed, and the tape on REV side is played for 2
minutes.
Note
* REV side of both Tape A and Tape B are played.
(5) Rewind is executed up to the top of tape.
(6) Returns to step 2, and repeat steps from 2 to 5.
[Function Change Mode]
* elect either VIDEO or MD of the external FUNCTION input.
Procedure:
1.
Turn on the power.
2.
Press the two buttons
MD (VIDEO)
and
I/1
at the same time.
The main power is turned on and the other function of the
previous function is selected and displayed.  “MD” or
“VIDEO”.
NO. Display action
Action contents
Final timing
1
TAPE A AG-6
Rewind the TAPE A
The top of tape
TAPE B AG-1
Rewind the TAPE B
2
TAPE A AG-2
FWD play the TAPE A
2 minutes playing
3
TAPE A AG-3
F.F. the TAPE A
20 second FF or the end
of tape
4
TAPE A AG-4
REV play the TAPE A
2 minutes playing
5
TAPE A AG-5
Rewind the TAPE A
The top of tape
6
TAPE B AG-2
FWD play the TAPE B
2 minutes playing
7
TAPE B AG-3
F.F. the TAPE B
20 second FF or the end
of tape
8
TAPE B AG-4
REV play the TAPE B
2 minutes playing
9
TAPE B AG-5
Rewind the TAPE B
The top of tape
18
HCD-DX60AV/RG70AV
SECTION  4
ELECTRICAL  ADJUSTMENTS
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
3. Mode:  Playback
4. Repeat step 1 to 3 in playback (REV) mode.
5. After the adjustments, apply suitable locking compound to the
parts adjusted.
Adjustment Location: Playback Head (Deck A).
Record/Playback/Erase Head (Deck B).
Screw
position
L-CH
peak
within
1dB
Output
level
L-CH
peak
R-CH
peak
within
1dB
Screw
position
R-CH
peak
set
test tape
P-4-A100
(10 kHz, –10 dB)
L-CH
R-CH
waveform of oscilloscope
in phase 45
°
90
°
135
°
180
°
good
wrong
PANEL board
PHONES jack (JACK701)
oscilloscope
V
H
+ +
32 
32 
0 dB=0.775 V
DECK  SECTION
1. Demagnetize the record/playback head with a head
demagnetizer.
2. Do not use a magnetized screwdriver for the adjustments.
3. After the adjustments, apply suitable locking compound to the
parts adjust.
4. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
5. The adjustments should be performed in the order given in this
service manual.  (As a general rule, playback circuit adjustment
should be completed before performing recording circuit
adjustment.)
6. The adjustments should be performed for both L-CH and R-
CH.
• Test Tape
Record/Playback Head Azimuth Adjustment
Note:
  Perform this adjustments for both decks
Procedure:
1. Mode:  Playback
DECK A      DECK B
set
test tape
P-4-A100
(10 kHz, –10 dB)
level meter
PANEL board
PHONES jack (JACK701)
32 
+
Tape
Signal
Used for
P-4-A100
10 kHz, –10 dB
Azimuth Adjustment
WS-48B
3 kHz, 0 dB
Tape Speed Adjustment
forward
reverse
19
HCD-DX60AV/RG70AV
Tape Speed Adjustment
DECK B
Note:
Start the Tape Speed adjustment as below after setting to the test
mode.
Procedure:
1. Turn the power switch on.
2. Press the
x
button, 
ENTER
button and
DISC 3
button
simultaneously.
(The “TEST MODE” on the fluorescent indicator tube display
while in the test mode.)
To exit from the test mode, press the
I/1
button.
Mode:  Playback
1. Insert the WS-48B into the deck A and the blank tape into the
deck B.
2. Press the
REC PAUSE/START
button on the deck B. Then the
deck B is at recording mode.
3. Set the deck A to playback mode.
4. Adjust SFR401 on the MAIN board so that frequency counter
reads 3,000 
±
 15 Hz.
5. Frequency difference between deck A and deck B the beginning
of the tape should be within 
±
1.5 %.
Adjustment Location:
set
test tape
WS-48B 
(3 kHz, 0 dB)
frequency counter
PANEL board
PHONES jack (JACK701)
+
32 
TUNER  SECTION
FM Tuned Level Adjustment
Procedure:
1.
Supply a 28 dB 98 MHz signal from the ANTENNA terminal.
2.
Tune the set to 98 MHz.
3.
Adjust SFR101 to the point (moment) when the TUNED
indicator will change from going off to going on.
Adjustment Location: MAIN board
Null Adjustment
Procedure:
1.
Supply a 60 dB 98 MHz signal from the ANTENNA terminal.
2.
Tune the set to 98 MHz.
3.
Measure voltage between pin wa of IC101.  Adjust T101 ubtil
the voltage becomes 0 V.
Adjustment Location: MAIN board
Adjustment Location
FM RF SSG
75 
 coaxial
Carrier frequency : 98 MHz
Modulation           : AUDIO 1 kHz, 75 kHz
                              deviation (100%)
Output level          : 28 dB  (at 75 W open)
FM ANTENNA terminal
(JK101)
set
FM RF SSG
75 
 coaxial
Carrier frequency : 98 MHz
Modulation           : AUDIO 1 kHz, 75 kHz
                              deviation (100%)
Output level          : 60 dB  (at 75 W open)
FM ANTENNA terminal
(JK101)
set
[MAIN BOARD] (Component side)
CN406
SFR401
TAPE SPEED
[MAIN BOARD] (Component side)
SRF101
FE101 or FE102
FM TUNED LEVEL
NULL
T101
IC101
Sample Value of Wow and Flutter: 0.3% or less W. RMS
(WS-48B)
20
HCD-DX60AV/RG70AV
CD SECTION
Note :
1. CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.
2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M
 impedance.
4. Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the
following checks.
S-Curve Check
Procedure :
1. Connect oscilloscope to TP (FEO).
2. Connect between TP (FEI) and TP (VC) by lead wire.
3. Connect between TP (AGCCON) and TP (GND) by lead wire.
4. Turn Power switch on.
5. Load a disc (YEDS-18) and actuate the focus search. (In
consequence of open and close the disc tray, actuate the focus
search)
6. Confirm that the oscilloscope waveform (S-curve) is
symmetrical between A and B. And confirm peak to peak level
within 4 
±
1 Vp-p.
7. After check, remove the lead wire connected in step 2 and 3.
Note :
• Try to measure several times to make sure than the ratio
of A : B or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
RF Level Check
Procedure :
1. Connect oscilloscope to TP (RF).
2. Connect between TP (AGCCON) and TP (GND) by lead wire.
3. Turned Power switch on.
4. Load a disc (YEDS-18) and playback.
5. Confirm that oscilloscope waveform is clear and check RF signal
level is correct or not.
6. After check, remove the lead wire connected in step 2.
BD board
Oscilloscope
TP(FEO)
TP(VC)
symmetry
S-curve waveform
within 4 
±
1Vp-p
A
B
TP(RF)
TP(VC)
BD board
oscilloscope
Note:
Clear RF signal waveform means that the shape “
” can be
clearly distinguished at the center of the waveform.
RF signal waveform
E-F Balance (1 Track jump) Check
Procedure:
1.
Connect oscilloscope to TP (TEO) and TP (VC) board.
2.
Turned Power switch on.
3.
Load a disc (YEDS-18) and playback the number five track.
4.
Press the  gG  button. (Becomes the 1 track jump mode.)
5.
Confirm that the level B and A (DC voltage) on the oscilloscope
waveform.
1 track jump waveform
Specification level:      
x
 100=less than 
±
22%
6.
After check, remove the lead wire connected in step 1.
RF PLL Free-run Frequency
Procedure :
1.
Connect frequency counter to test point (XPCK) with lead wire.
2.
Turned Power switch on.
3.
Put the disc (YEDS-18) in to play the number five track.
Confirm that reading on frequency counter is 4.3218MHz.
VOLT/DIV : 200mV
TIME/DIV : 500ns
level : 1.45 
±
 0.3Vp-p
oscilloscope
BD board
TP (TEO)
TP (VC)
+
0V
Center of
waveform
B
Symmetry
A (DC voltage)
level=1.3
±
0.6Vp-p
A
B
+
frequency counter
BD board
TP (XPCK)
Page of 73