0 dB=0.775 V
DECK  SECTION
Precaution
1. Demagnetize the record/playback head with a head
demagnetizer.
2. Do not use a magnetized screwdriver for the adjustments.
3. After the adjustments, apply suitable locking compound to the
parts adjust.
4. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
5. The adjustments should be performed in the order given in this
service manual.  (As a general rule, playback circuit adjustment
should be completed before performing recording circuit
adjustment.)
6. The adjustments should be performed for both L-CH and R-
CH.
7. Switches and controls should be set as follows unless otherwise
specified.
8. Set to the test mode.
(1) Press the  ?/1  button to turn the power ON.
(2) Select the function “TAPE A or B”.
(3) Press the button of  x (TC-B)  , [TUNER ENTER], and [DISC
3] simultaneously, to set the tape deck test mode and displays
“TEST MODE” on the fluorescent indicator tube.
(4) To release from the test mode, press the  ?/1  button.
• Test Tape
SECTION 6
ELECTRICAL ADJUSTMENTS
SECTION 5
MECHANICAL ADJUSTMENTS
Precaution
1. Clean the following parts with a denatured alcohol-moistened
swab:
record/playback heads
pinch rollers
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head
demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
Torque Measurement
Mode
Torque Meter
Meter Reading
2.9 – 6.9 mN • m
FWD
(30 to 70 g • cm)
CQ-102C
(0.42 – 0.97 oz • inch)
FWD
0.19 – 0.59 mN • m
back tension
(2 to 6 g • cm)
(0.03 – 0.08 oz • inch)
7.8 – 16.7 mN • m
FF/REW
CQ-201B
(80 to 170 g • cm)
(1.11 – 2.36 oz • inch)
Tape
Signal
Used for
P-4-A100
10 kHz, –10 dB
Azimuth Adjustment
WS-48B
3 kHz, 0 dB
Tape Speed Adjustment
26
HCD-ZX9
Record/Playback Head Azimuth Adjustment
Note:
 Perform this adjustments for both decks
Procedure:
1. Mode:  Playback (FWD)
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
3. Mode:  Playback
4. Repeat step 1 to 3 in playback (REV) mode.
5. After the adjustments, apply suitable locking compound to the
pats adjusted.
Screw
position
L-CH
peak
within
1dB
Output
level
L-CH
peak
R-CH
peak
within
1dB
Screw
position
R-CH
peak
set
test tape
P-4-A100
(10 kHz, – 10 dB)
R-CH
oscilloscope
L-CH
R-CH
V
H
waveform of oscilloscope
in phase 45
°
90
°
135
°
180
°
good
wrong
MAIN board
VIDEO/MD
 OUT jack (J701)
L-CH
reverse
forward
Adjustment Location: Playback Head (Deck A).
Record/Playback/Erase Head (Deck B).
DECK A      DECK B
set
MAIN board
VIDEO/MD OUT jack (J701)
L-CH, R-CH
+
level meter
test tape
P-4-A100
(10 kHz, – 10 dB)
27
HCD-ZX9
CD  SECTION
Note:
1. CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.
2. Use YEDS-18 (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M impedance.
4. Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the
following checks.
S-Curve Check
Procedure:
1. Connect oscilloscope to TP102 (FE1) and TP117 (VC).
2. Press the  ?/1  button to turn the power ON.
3. Load a disc (YEDS-18) and actuate the focus search. (In
consequence of open and close the disc tray, actuate the focus
search)
4. Confirm that the oscilloscope waveform (S-curve) is
symmetrical between A and B. And confirm peak to peak level
within 3 ±0.5 Vp-p.
Note:
• Try to measure several times to make sure than the ratio of
A : B or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
RF Level Check
Procedure:
1. Connect oscilloscope to TP124 (RFACO) and TP117 (VC).
2. Press the  ?/1  button to turn the power ON.
3. Load a disc (YEDS-18) and playback.
4. Confirm that oscilloscope waveform is clear and check RFAC
signal level is correct or not.
BD81A board
Oscilloscope
TP0102(FE1)
TP117(VC)
TP124(RFACO)
TP117(VC)
BD81A board
oscilloscope
Note:
Clear RF signal waveform means that the shape “
◊” can be
clearly distinguished at the center of the waveform.
VOLT/DIV : 200mV
TIME/DIV : 500ns
level : 1.3 
±
 0.3Vp-p
TP117
 (VC)
TP124
(RFACO)
TP0102
 (FE1)
IC101
Checking Location:
symmetry
S-curve waveform
within 3 
±
0.5Vp-p
A
B
28
HCD-ZX9
SECTION 7
DIAGRAMS
7-1. CIRCUIT BOARDS LOCATION
VOLTAGE SELECTOR board
LIGHTING board
POWER SWITCHING
PANEL board
POWER SWITCH board
TC-A board
VOL board
MIC board
TC-B board
GAME-IN/HP board
CD-R board
CURSOR board
CD-L board
JOG board
FUNCTION SW board
MAIN board
SENSOR board
TRANS board
SURROUND board
POWER board
MD-94 board
SE-130 board
BD81A board
Page of 94
Display

Click on the first or last page to see other FST-ZX9 / HCD-ZX9 / LBT-ZX9 service manuals if exist.