Sony DVP-S9 / MHC-S9D Service Manual ▷ View online
11
DVP-S9
SECTION 4
TEST MODE
Note:
Use following buttons in the test mode.
no mark : Button of DVD/video CD/CD player (DVP-S9)
*1
: Button of A/V amplifier (TA-S9D)
*2
: Button of tuner (ST-S9)
[CHANGE-OVER THE COLOR SYSTEM]
• The color system can be changed over NTSC or PAL.
Procedure:
1. Press the
Procedure:
1. Press the
I/1
*
1
button to turn the power on.
2. Turn the
[FUNCTION]
*
1
knob to select
“DVD”, and press
the
x
button.
3. While pressing the both
[RETURN]
and
[REPEAT]
buttons,
turn the power off.
4. Press the
I/1
*
1
button to turn the power on. The color sys-
tem is changed over.
[COLD RESET]
• The cold reset clears all data including preset data stored in the
RAM to initial conditions. Execute this mode when returning
the set to the customer.
the set to the customer.
Procedure 1:
1. Press the
1. Press the
I/1
*
1
button to turn the power on.
2. While pressing the both
[PLAY MODE]
and
x
buttons, press
the
M
button.
3. The set is reset, and becomes standby state.
Procedure 2:
1. Press the
1. Press the
I/1
*
1
button to turn the power on.
2. While pressing the
[DIGITAL]
*
1
button, press the
[DISPLAY]
*
2
button.
3. The set is reset, and becomes standby state.
[DVD DELIVERY MODE]
• This mode moves the optical pick-up to the position durable to
vibration. Use this mode when returning the set to the customer
after repair.
after repair.
Procedure:
1. Press the
1. Press the
I/1
*
1
button to turn the power on.
2. Turn the
[FUNCTION]
*
1
knob to select “DVD”.
3. While pressing the
[EQ ON/OFF]
*
1
button, press the
I/1
*
1
button.
4. The message “LOCK” is displayed on the fluorescent indica-
tor tube of tuner unit and turn the power off automatically, and
the DVD delivery mode is set.
the DVD delivery mode is set.
[GC TEST MODE]
Enter the GC Test Mode
Procedure 1:
1. Press the
1. Press the
I/1
*
1
button to turn the power on.
2. While pressing the both
[PLAY MODE]
and
x
buttons, press
the
Z
(DISC 1) button.
3. LEDs and fluorescent indicator tube are all turned on of all
units.
Procedure 2:
1. Press the
1. Press the
I/1
*
1
button to turn the power on.
2. While pressing the both
[STEREO/MONO]
*
2
and
[CINEMA STUDIO C]
*
1
buttons, press the
[CLOCK/TIMER]
*
2
button.
3. LEDs and fluorescent indicator tube are all turned on of all
units.
Version Display Mode
Procedure:
1. Enter the GC test mode.
2. Each time the
1. Enter the GC test mode.
2. Each time the
[DISC 1]
or
[TUNER MEMORY]
*
2
button is
pressed, microcomputer or mechanism deck version is dis-
played of each unit.
played of each unit.
3. Press the
[DISC 3]
or
[TUNING +]
*
2
button to detail is dis-
played the version.
Key Check Mode
Procedure:
1. Enter the GC test mode.
2. Press the
1. Enter the GC test mode.
2. Press the
[DISC 2]
or
[TUNING --]
*
2
button to set the key check
mode, and displays “K 0 J 0 V 0” on the fluorescent indicator
tube of tuner unit.
tube of tuner unit.
3. All buttons are pressed of video CD unit, all LEDs are blink-
ing of video CD unit. (not change the display of fluorescent
indicator tube)
indicator tube)
Releasing the GC Test Mode
To release from this mode, press three buttons in the same manner
as entering this mode or disconnect the power cord.
as entering this mode or disconnect the power cord.
[DVD SERVICE MODE]
• This mode can run the DVD sled motor optionally. Use this
mode, for instance, when cleaning the optical pick-up.
Procedure:
1. Press the
1. Press the
I/1
*
1
button to turn the power on.
2. Turn the
[FUNCTION]
*
1
knob to select “DVD”.
3. While pressing the both
[PLAY MODE]
and
x
buttons, press
the
.
button.
4. Set to the DVD service mode.
5. With the DVD in stop status, press the
5. With the DVD in stop status, press the
M
button to move
the optical pick-up to outside track, or press the
m
button
to inside track.
6. To release from this mode, perform as follows.
1) Move the optical pick-up to the most inside track.
2) Disconnect the power cord.
2) Disconnect the power cord.
Notes:
• Always move the optical pick-up to most inside track when
releasing from this mode. Otherwise, a disc will not be un-
loaded.
loaded.
• Do not run the sled motor excessively, otherwise the gear can
be chipped.
[DVD CANCELLATION MODE OF REPEAT LIMI-
TATION]
TATION]
• This mode can cancel the DVD repeat limitation (5 times).
Procedure:
1. Press the
Procedure:
1. Press the
I/1
*
1
button to turn the power on.
2. Turn the
[FUNCTION]
*
1
knob to select “DVD”.
3. While pressing the both
[PLAY MODE]
and
x
buttons, press
the
[REPEAT]
button.
4. DVD repeat limitation is canceled.
5. To release this mode, disconnect the power cord.
5. To release this mode, disconnect the power cord.
[DVD DISC TRAY LOCK MODE FOR BURGLARY
PREVENTION]
PREVENTION]
Procedure:
1. Press the
1. Press the
I/1
*
1
button to turn the power on.
2. Turn the
[FUNCTION]
*
1
knob to select “DVD”.
3. While pressing the both
[PLAY MODE]
and
x
buttons, press
the
m
button, turn the power off.
12
DVP-S9
[GENERAL DESCRIPTION]
The Test Mode allows you to make diagnosis and adjustment eas-
ily using the remote commander and monitor TV. The instructions,
diagnostic results, etc. are given on the on-screen display (OSD).
ily using the remote commander and monitor TV. The instructions,
diagnostic results, etc. are given on the on-screen display (OSD).
[STARTING TEST MODE]
1.
Press the
I/1
*
1
button to turn the power on.
2.
Turn the
[FUNCTION]
*
2
knob to select “DVD”.
3.
While pressing the
x
and
[PLAY MODE]
button, press
the
.
button to enter the test mode.
4.
It displays “TEST MODE” on the fluorescent indicator tube,
and displays the Test Mode Menu on the monitor screen as
follows. (At the bottom of the menu screen, the model name
and revision number are displayed)
and displays the Test Mode Menu on the monitor screen as
follows. (At the bottom of the menu screen, the model name
and revision number are displayed)
Test Mode Menu
0. Syscon Diagnosis
1. Drive Auto Adjustment
2. Drive Manual Operation
3. Mecha Aging
4. Emergency History
5. Version Information
6. Video Level Adjustment
Exit: POWER Key
_
Model
: xxx-xxxx_xx
Revision : 1.xxx
5.
To execute each function, select the desired menu and press its
number on the remote commander (RM-SD390AV or RM-
SD395AV).
number on the remote commander (RM-SD390AV or RM-
SD395AV).
6.
To release from test mode, press the
I/1
*
1
button and turn
the power off.
1.
All
All items continuous check
This menu checks all diagnostic items continuously. Normally, all
items are checked successively one after another automatically un-
less an error is found, but at a certain item that requires judgment
through a visual check to the result, the following screen is dis-
played for the key entry.
This menu checks all diagnostic items continuously. Normally, all
items are checked successively one after another automatically un-
less an error is found, but at a certain item that requires judgment
through a visual check to the result, the following screen is dis-
played for the key entry.
### Syscon Diagnosis ###
Diag All Check
No. 2 Version
2-3. ROM Check Sum
Check Sum = 2005
Press NEXT Key to Continue
Press PREV Key to Repeat
_
For the ROM Check, the check sum calculated by the Syscon is
output, and therefore you must compare it with the specified value
for confirmation.
Following the message, press
output, and therefore you must compare it with the specified value
for confirmation.
Following the message, press
>
key to go to the next item,
or
.
key to repeat the same check again. To quit the diagnosis
and return to the Check Menu screen, press
x
or
[ENTER]
key.
If an error occurred, the diagnosis is suspended and the error code
is displayed as shown below.
is displayed as shown below.
### Syscon Diagnosis ###
3-3. EEPROM Check
Error 03: EEPROM Write/Reed N
Address
: 00000001
Write Data : 2492
Read Data
: 2490
Press NEXT Key to Continue
Press PREV Key to Repeat
_
[SYSCON DIAGNOSIS]
The same contents as board detail check by serial interface can be
checked from the remote commander.
On the Test Mode Menu screen, press
checked from the remote commander.
On the Test Mode Menu screen, press
[10/0]
key on the remote
commander, and the following check menu will be displayed.
### Syscon Diagnosis ###
Check Menu
0. Quit
1. All
2. Version
3. Peripheral
4. Servo
5. Supply
6. AV Decoder
7. Video
8. Audio
_
0.
Quit
Quit the Syscon Diagnosis and return to the Test Mode Menu.
Press
x
key to quit the diagnosis, or
>
key to repeat the same
item where an error occurred, or
.
key to continue the check
from the item next to faulty item.
Ver 1.6
13
DVP-S9
Selecting 2 and subsequent items calls the submenu screen of each
item.
For example, if “5. Supply” is selected, the following submenu
will be displayed.
item.
For example, if “5. Supply” is selected, the following submenu
will be displayed.
### Syscon Diagnosis ###
Check Menu
No. 5 Supply
0. Quit
1. All
2. ARP Register Check
3. ARP to RAM Data Bus
4. ARP to RAM Address Bus
5. ARP RAM Check
_
0.
Quit
Quit the submenu and return to the main menu.
1.
All
All submenu items continuous check
This menu checks 2 and subsequent items successively. At the item
where visual check is required for judgment or an error occurred,
the checking is suspended and the message is output for key entry.
Normally, all items are checked successively one after another au-
tomatically unless an error is found.
This menu checks 2 and subsequent items successively. At the item
where visual check is required for judgment or an error occurred,
the checking is suspended and the message is output for key entry.
Normally, all items are checked successively one after another au-
tomatically unless an error is found.
Selecting 2 and subsequent items executes respective menus and
outputs the results.
For the contents of each submenu, see “Check Items List”.
outputs the results.
For the contents of each submenu, see “Check Items List”.
General Description of Checking Method
2.
2.
Version
(2-2) Revision
ROM revision number is displayed.-
Error: Not detected.
The revision number defined in the source file of ROM (At
the beginning of mass production, the Flash ROM of IC107
is used) is displayed with four digits.
Error: Not detected.
The revision number defined in the source file of ROM (At
the beginning of mass production, the Flash ROM of IC107
is used) is displayed with four digits.
(2-3) ROM Check Sum
Check sum is calculated.
Error: Not detected.
The 8-bit data are added at addresses 0x000F0000 ~
0x002EFFFF of ROM (IC107) and the result is displayed
with 4-digit hexadecimal number. Error is not detected.
Compare the result with the specified value.
Error: Not detected.
The 8-bit data are added at addresses 0x000F0000 ~
0x002EFFFF of ROM (IC107) and the result is displayed
with 4-digit hexadecimal number. Error is not detected.
Compare the result with the specified value.
(2-4) Model Type
Model code is displayed.
Error: Not detected.
The model code read from EEPROM (IC101) is displayed
with 2-digit hexadecimal number.
Error: Not detected.
The model code read from EEPROM (IC101) is displayed
with 2-digit hexadecimal number.
(2-5) Region
Region code is displayed.
Error: Not detected.
The region code determined from the model code is displayed.
Error: Not detected.
The region code determined from the model code is displayed.
3.
Peripheral
(3-2) EEPROM Check
Data write
→ read, and accord check
Error 03: EEPROM write/read discord
Data 0x9249, 0x2942, 0x4294 are written to addresses
0x00~0xFF of EEPROM (IC101), then read and checked.
Before writing, the data are saved, then after checking, they
are written to restore the contents of EEPROM.
Data 0x9249, 0x2942, 0x4294 are written to addresses
0x00~0xFF of EEPROM (IC101), then read and checked.
Before writing, the data are saved, then after checking, they
are written to restore the contents of EEPROM.
4.
Servo
(4-2) Servo DSP Check
Data write
→ read, and accord check
Error 12: Read data discord
Data 0x9249, 0x2942, 0x4294 are written to the address
0x602 of RAM in the Servo DSP (IC302), then read and
checked.
Data 0x9249, 0x2942, 0x4294 are written to the address
0x602 of RAM in the Servo DSP (IC302), then read and
checked.
(4-3) DSP Driver Test
Test signal data
→ DSP Driver
Error: Not detected.
Caution: Do not conduct this test with a mechanical deck
connected.
The maximum voltage is applied to the Servo Driver IC
(IC401). If mechanical deck is connected, the motor and
optics could be damaged. Disconnect mechanical deck fol-
lowing the output message, then enter specified 4- or 5-
digit number from the remote commander, and press the
Caution: Do not conduct this test with a mechanical deck
connected.
The maximum voltage is applied to the Servo Driver IC
(IC401). If mechanical deck is connected, the motor and
optics could be damaged. Disconnect mechanical deck fol-
lowing the output message, then enter specified 4- or 5-
digit number from the remote commander, and press the
[ENTER]
. The test is conducted only when the input data
accord. Check the output level, then press the
>
to fin-
ish the test.
This test is skipped if “All” is selected.
This test is skipped if “All” is selected.
Supplement: How to disconnect mechanical deck
Disconnect flat cables connected to the CN010 and CN015
of MB board. Also, disconnect harness from the CN203.
Disconnect flat cables connected to the CN010 and CN015
of MB board. Also, disconnect harness from the CN203.
Ver 1.6
14
DVP-S9
5.
Supply
Caution: Do not conduct this check with a mechanical deck con-
nected.
An access is made to the stream supply and servo control
IC (IC302) and external RAM (IC303) using check data.
If mechanical deck is connected, the motor and optics
could be damaged. This check is also executed by the
“All” menu item.
An access is made to the stream supply and servo control
IC (IC302) and external RAM (IC303) using check data.
If mechanical deck is connected, the motor and optics
could be damaged. This check is also executed by the
“All” menu item.
Supplement: How to disconnect mechanical deck
Disconnect flat cables connected to the CN010 and
CN015 of MB board. Also, disconnect harness from
the CN203.
CN015 of MB board. Also, disconnect harness from
the CN203.
(5-2) ARP Register Check
Data write
→ read, and accord check
Error 08: ARP register write, and read data discord
Data 0x00 to 0xFF are written to the TMAX register (ad-
dress 0xC6) in ARP (IC302), then they are read and checked.
Data 0x00 to 0xFF are written to the TMAX register (ad-
dress 0xC6) in ARP (IC302), then they are read and checked.
(5-3) ARP to RAM Data Bus
Data write
→ read, and accord check
Error 09: ARP
←→ RAM data bus error
Data 0x0001 to 0x8000 where one bit each is set to 1 are
written to the address 0 of RAM (IC303) connected to the
ARP (IC302) through the bus, then they are read and
checked. In case of discord, written bit pattern and read
data are displayed. If data where multiple bits are 1 are
read, the bits concerned may touch each other. Further, if
data where certain bit is always 1 or 0 regardless of written
data, the line could be disconnected or shorted.
written to the address 0 of RAM (IC303) connected to the
ARP (IC302) through the bus, then they are read and
checked. In case of discord, written bit pattern and read
data are displayed. If data where multiple bits are 1 are
read, the bits concerned may touch each other. Further, if
data where certain bit is always 1 or 0 regardless of written
data, the line could be disconnected or shorted.
(5-4) ARP to RAM Address Bus
Data write
→ other address read discord check
Error 10: ARP
→ RAM address bus error
Caution: Address and data display in case of an error is
different from the display of other diagnosis (de-
scribed later).
scribed later).
Before starting the test, all addresses of RAM (IC303) are
cleared to 0x0000.
First, 0xA55A is written to the address 0x00000, and the
address data are read and checked from addresses 0x00001
to 0x80000 while shifting 1 bit each. Next, the data at that
address is cleared, and it is written to the address 0x00001,
and read and checked in the same manner. This check is
repeated up to the address 0x80000 while shifting the ad-
dress data by 1 bit each.
If data other than 0 is read at the addresses except written
address, an error is given because all addresses were al-
ready cleared to 0. In this check, the error display pattern is
different from that of other diagnosis; read data, written
address, and read address are displayed in this order. How-
ever, the message uses same template, and accordingly ex-
change Address and Data when reading. The following dis-
play, for example,
cleared to 0x0000.
First, 0xA55A is written to the address 0x00000, and the
address data are read and checked from addresses 0x00001
to 0x80000 while shifting 1 bit each. Next, the data at that
address is cleared, and it is written to the address 0x00001,
and read and checked in the same manner. This check is
repeated up to the address 0x80000 while shifting the ad-
dress data by 1 bit each.
If data other than 0 is read at the addresses except written
address, an error is given because all addresses were al-
ready cleared to 0. In this check, the error display pattern is
different from that of other diagnosis; read data, written
address, and read address are displayed in this order. How-
ever, the message uses same template, and accordingly ex-
change Address and Data when reading. The following dis-
play, for example,
### Syscon Diagnosis ###
5-4. ARP to RAM Address Bus
Error 10: ARP - RAM Address B
Address
: 0000A55A
Write Data : 00000000
Read Data
: 00080000
Press NEXT Key to Continue
Press PREV Key to Repeat
_
shows the data 0xA55A was read from address 0x00080000
though it was written to the address 0x00000000. This im-
plies that these addresses are in the form of shadow. Also,
if the read data is not 0xA55A, another error will be present.
though it was written to the address 0x00000000. This im-
plies that these addresses are in the form of shadow. Also,
if the read data is not 0xA55A, another error will be present.
(5-5) ARP RAM Check
Data write
→ read, and accord check
Error 11: ARP RAM read data discord
The program code data stored in ROM are copied to all
areas of RAM (IC303) connected to the ARP (IC302)
through the bus, then they are read and checked if they ac-
cord. If the detail check was selected initially, the data are
written to all areas and read, then the same test is conducted
once again with the data where all bits are inverted between
1 and 0. If discord is detected, faulty address, written data,
and read data are displayed following the error code 11,
and the test is suspended.
The program code data stored in ROM are copied to all
areas of RAM (IC303) connected to the ARP (IC302)
through the bus, then they are read and checked if they ac-
cord. If the detail check was selected initially, the data are
written to all areas and read, then the same test is conducted
once again with the data where all bits are inverted between
1 and 0. If discord is detected, faulty address, written data,
and read data are displayed following the error code 11,
and the test is suspended.
Ver 1.6
Click on the first or last page to see other DVP-S9 / MHC-S9D service manuals if exist.