DVP-NS36/NS37/NS45P/NS55P/NS61P/NS63P
5-5
Pin No.
Pin name
Type
Function
200
Y/G
Output
Green signal or Y signal output
201
DACVSSA
Ground
Ground pin for Video DAC circuitry
202
B/Cb/Pb
Output
Blue signal or Cb signal output
203
R/Cr/Pr
Output
Red  signal or Cr signal output
204
DVDD3
Power
3.3V power pin for Video DAC digital circuitry
205
MIC
Input  SMT
Karaoke Microphone detect signal
206
VOICE (MV-50 only)
Output SMT
Karaoke voice function (not used)
SCORE (MV-51 only)
LOW
Karaoke score function
(Full Karaoke model only)
ECHO_ON OFF
LOW
Karaoke Echo function status output (H: Echo on; L: Echo off)
(MV-51 only)
(5 Karaoke model only)
207
KRMOD
Output SMT
Karaoke Mode Status Output (H: Normal, L: Karaoke)
Output Default
208
SCK
Output
ADAC Serial Clock (S/W method by 8032)
209
WIDE
Output
Video aspect ratio control SW
Output Default
210
SDO
Output
ADAC Serial data output (S/W method by 8032)
211
xSCS
Output
Chip select for ADAC (Low active, SW method by 8032)
212
DVDD3
Power
3.3V power pin for internal digital circuitry
213
ALRCK
Output  PD,SMT
Audio left/right channel clock (ADAC LRCK output)
214
ABCK
Output
Audio Bit Clock output (ADAC BCK output)
215
ACLK
Output
Master clock output for Audio DAC (ADAC CLK Master clock output)
216
DVSS
Ground
Ground pin for internal digital circuitry
217
ASDATA0
Output
Not used
218
ASDATA1
Output
Not used
219
ASDATA2
Output
Not used
220
xRST
Default Low
Reset output signal for ADAC (Low Active)
221
DVDD18
Power
1.8V power pin for intenal digital circuitry
222
ASDATA4
Output PD,SMT
Audio serial data 4: Down-mixed L/R
223
DVSS
Ground
Ground pin for internal digital circuitry
224
Disc/XEXT (MV-50 only)
Output
Disc/External input select output signal (H: Disc, L: External)
 XVOICE (MV-51 only)
Input
Karaoke Voice function
225
SPDIF
Output
SPDIF output
226
RFGND18
Ground
Ground pin for internal analog circuitry
227
RFVDD18
Power
1.8V power pin for internal analog circuitry
228
XTALO
Output
27M crystal output
229
XTALI
Input
27M crystal input
230
JITFO
Analog Output
The output terminal of RF jitter
231
JITFN
Analog Input
The input terminal of RF jitter
232
PLLVSS
Ground
Ground pin for data PLL and related analog circuitry
233
IDACEXLP
Analog Output
Data PLL DAC Low-pass filter
234
PLLVDD3
Power
3.3V power pin for data PLL and related analog circuitry
235
LPFON
Analog Output
The negative output terminal of loop filter amplifier
236
LPFIP
Analog Input
The positive input terminal of loop filter amplifier
237
LPFIN
Analog Input
The negative input of loop filter amplifier
238
LPFOP
Analog Output
The positive output of loop filter amplifier
239
ADCVDD3
Power
Power  pin for ADC circuitry
240
NC
Not used
241
ADCVSS
Ground
Ground pin for ADC circuitry
242
NC
Not used
243
NC
Not used
244
RFVDD3
Power
3.3V power pin for RF digital circuitry
245
RFRPDC
Analog Output
RF ripple detect output
246
RFRPAC
Analog Input
RF ripple detect input (through AC-coupling)
DVP-NS36/NS37/NS45P/NS55P/NS61P/NS63P
5-6
5-6E
Pin No.
Pin name
Type
Function
247
HRFZC
Analog Input
High frequency RF ripple zero crossing capasitor connecting
248
CRTPLP
Analog Output
Defect level filter capacitor connecting
249
RFGND
Ground
Ground pin for RF digital circuitry
250
NC
Not used
251
NC
Not used
252
OSP
Analog Output
RF  Offset cancellation capacitor connecting
253
OSN
Analog Output
RF  Offset cancellation capacitor connecting
254
RFGC
Analog Output
RF AGC loop capacitor conecting for DVD-ROM
255
IREF
Analog Input
Input reference current input
256
AVDD3
Power
3.3V power pin for analog circuirtry
6-1
DVP-NS36/NS37/NS45P/NS55P/NS61P/NS63P
SECTION 6
TEST MODE
6-1.
EXECUTING IOP MEASUREMENT
In order to execute IOP measurement, the following standard
procedures must be followed.
(1)
In standby mode, press [TOP MENU], [CLEAR], [POWER] to
enter Remocon Diagnosis Mode.
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version information
5. Video Level Adjustment
Model
: xxx xxx xxx
IF-con  Ver
: xxx
Syscon  Ver : xxx
(2)
Select “2. Drive Manual Operation” by pressing the 2 key on
the remote commander. The screen will appear as below.
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
0. Return to top Menu
(3)
Select “3. Manual Adjustment” by pressing the 3 key on the
remote commander. The screen will appear as below.
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
$4 Change Value
[RETURN] Return to previous menu
(4)
Select Iop by pressing 6 key on the remote commander.
(5)
Wait until a hexadecimal number appear.
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop. ED:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
$4 Change Value
[RETURN] Return to previous menu
(6)
Convert data from hexadecimal to decimal.
(7)
Use the following formula to calculate IOP in mA
IOP (mA)=IOP (decimal) x 0.622678.
(8)
Press [RETURN] to return back to previous menu.
(9)
Press  - to return to Top Menu and power OFF the DVD
Player.
6-2.
EMERGENCY HISTORY CHECK
Information of Emergency History.
(1)
In standby mode, press 
[TOP MENU]
[CLEAR]
[POWER]
 to
enter Remocon Diagnosis Mode.
(2)
Select “3. Emergency History”.
Emg. History Check
Laser Hours
CD
999h
59min
DVD
999h
59min
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
2. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
[Next] Next Page [Prev] Prev Page
-
 Return to Top Menu
(3)
Laser Hours
DVD Laser ON time. (Total ON time)
CD Laser ON time. (Total ON time)
(4)
Emergency History
The history information from last “1” to “10” can be scrolled
with [NEXT] key or [PREV] key.
(5)
Error code
Example of Error code
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
6-2
DVP-NS36/NS37/NS45P/NS55P/NS61P/NS63P
(6)
Error code list
01: Communication error (No reply from syscon)
02: Syscon hung up
03: Power OFF request when syscon hung up
19: Thermal shutdown
24: MoveSledHome error
25: Mecha move error (5 Changer)
26: Mecha move stack error
30: DC Motor adjustment error
31: DPD offset adjustment error
32: TE Balance adjustment error
33. TE Sensor adjustment error
34. TE loop gain adjustment error
35. FE loop gain adjustment error
36. Bad jitter after adjustment
40. Focus NG
42. Focus Layer Jump NG
52. Open kick spindle error
51: Spindle stop error
60: Focus on error
61: Seek fail error
62: read Qdata/ID error
70: Lead In Data Read Fail
71: TOC read time out (CD)
80: Can’t Buffering
81: Unknown media type
(7)
Error code parameters
Example of Error code
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
This is the detailed contents of error information
(8)
Laser hours at error happend.
Example of Error code
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
This is Laser hours when an error happened.
(9)
How to Clear laser hours
Press [DISPLAY], [CLEAR] keys in this order.
Both CD and DVD data are cleared.
Emg. History Check
Laser Hours
CD
0 h
0min
DVD
0 h
0min
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
2. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
[Next] Next Page [Prev] Prev Page
-
 Return to Top Menu
(10) How to Clearing Emergency code
Press [TOPMENU], [CLEAR] keys in this order.
All emergency code are cleared.
Emg. History Check
Laser Hours
CD
999h
59min
DVD
999h
59min
1. 00 00 00 00
00 00 00 00
00 00 00 00
00 00 00 00
2. 00 00 00 00
00 00 00 00
00 00 00 00
00 00 00 00
[Next] Next Page [Prev] Prev Page
(11) Press - key, return to TOP MENU.
6-3.
INITIALIZING SETUP DATA
How to initializing setup data.
(1)
In standby mode, press [TOP MENU], [CLEAR], [POWER] to
enter Remocon Diagnosis Mode.
(2)
Select “3. Emergency History”.
Emg. History Check
Laser Hours
CD
999h
59min
DVD
999h
59min
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
2. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
[Next] Next Page [Prev] Prev Page
-
 Return to Top Menu
(3)
Initializing setup data
Press [MENU], [CLEAR] keys in this order.
The data have been initialized when “Initialize setup data...”
mesage is displayed.
Emg. History Check
Laser Hours
CD
999h
59min
DVD
999h
59min
Initialize setup data ...