37
VIDEO SECTION
FREQUENCY ADJUSTMENT
Connection:
Procedure:
1. Connect the frequency counter to check point of the VIDEO
board.
2. Turned  ?/1  button switch on.
3. Press the  FUNCTION  button to select the CD.
4. Adjust CT503 on the VIDEO board so that the frequency counter
reading 27.0 MHz 
±
 80 Hz at stop status.
Adjustment Location:
[VIDEO BOARD] (SIDE A)
J301
J302
CN501
CN503
SL503
SL502
SL501
CHECK LED
CN502
IC507
(GND)
(27MHz)
CT503
VIDEO
Frequency
Adjustment
VIDEO board
(27 MHz)
frequency counter
38
6-1. PARTS REPLACEMENT AND ADJUSTMENT
If malfunctions caused by Optical pick-up such as sound skipping are suspected, follow the following check.
Check before replacement
Other faults are suspected.
Check the threading mechanism, etc.
Start
NG
NG
NG
OK
OK
OK
Laser Power Check
6-6-2.
(See page 41)
6-6-3.
(See page 41)
6-6-4.
(See page 42)
Iop Compare
Auto Check
Replace Optical pick-up or MDM-7B
  MD SECTION
39
6-6-4. Auto Check
(See page 42)
Start
YES
NO
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES
Replace IC195
Replace OP or IC195
Replace IC101, IC195, or D101
6-11. Iop NV SAVE (See page 45)
Replace OP, IC190, or IC195
Replace OP, IC102, IC190, 
or IC195
Replace OP, IC101, IC151, 
or IC195
Replace OP
Replace the spindle motor
End adjustments
After turning off and then on the power, 
initialize the EEPROM
For details, refer to 4-11. WHEN MEMORY NG IS 
DISPLAYED (See page 32)
• Abbreviation
OP: Optical pick-up
6-7. INITIAL SETTING OF ADJUSTMENT VALUE 
(See page 44)
6-9. TEMPERATURE COMPENSATION OFFSET 
ADJUSTMENT (See page 44)
6-10. LASER POWER ADJUSTMENT (See page 44)
6-12. TRAVERSE ADJUSTMENT (See page 45)
6-13. FOCUS BIAS ADJUSTMENT (See page 46)
6-16. AUTO GAIN CONTROL OUTPUT LEVEL
ADJUSTMENT (See page 47)
OP change in Err Display mode
Iop write
Spindle change in Err Display mode
Adjustment flow
40
Parts to be replaced
6-7. Initial setting of adjustment values
6-8. Recording and displaying the Iop information
6-9. Temperature compensation offset adjustment
6-10. Laser power adjustment
6-11. Iop NV Save
6-12. Traverse adjustment
6-13. Focus bias adjustment
6-16. Auto gain control output level adjustment
6-6-4. Auto Check
6-2. PRECAUTIONS FOR CHECKING LASER DIODE
EMISSION
To check the emission of the laser diode during adjustments, never
view directly from the top as this may lose your eye-sight.
6-3. PRECAUTIONS FOR USE OF OPTICAL PICK-
UP (KMS-260B/J1N)
As the laser diode in the optical pick-up is easily damaged by static
electricity, solder the laser tap of the flexible board when using it.
Before disconnecting the connector, desolder first. Before connect-
ing the connector, be careful not to remove the solder. Also take
adequate measures to prevent damage by static electricity. Handle
the flexible board with care as it breaks easily.
Optical pick-up flexible board
6-4. PRECAUTIONS FOR ADJUSTMENTS
1) When replacing the following parts, perform the adjustments
and checks with 
 in the order shown in the following table.
2) Set the test mode when performing adjustments.
After completing the adjustments, exit the test mode.
Perform the adjustments and checks in “group S” of the test mode.
3) Perform the adjustments to be needed in the order shown.
4) Use the following tools and measuring devices.
• Check Disc (MD) TDYS-1
(Parts No. 4-963-646-01)
• Test Disk (MDW-74/GA-1) (Parts No. 4-229-747-01)
• Laser power meter LPM-8001 (Parts No. J-2501-046-A)
or
MD Laser power meter 8010S (Parts No. J-2501-145-A)
• Oscilloscope (Measure after performing CAL of prove.)
• Digital voltmeter
• Thermometer
• Jig for checking BD (MD) board waveform
(Parts No. : J-2501-196-A)
Optical
Pick-up
IC101
IC102
IC151
IC190
IC195
D101
pick-up
flexible board
laser tap
5) When observing several signals on the oscilloscope, etc.,
make sure that VC and ground do not connect inside the oscillo-
scope.
(VC and ground will become short-circuited.)
6) Using the above jig enables the waveform to be checked without
the need to solder.
(Refer to Servicing Note on page 9.)
7) As the disc used will affect the adjustment results, make sure
that no dusts nor fingerprints are attached to it.
Adjustment
Page of 127