– 17 –
4-7. TEST MODE FOR MD SECTION
4-7-1. Setting the Test Mode
•
Turn OFF the power of the unit, and set the test mode by pressing
the following keys together.
the following keys together.
FUNCTION + PRESET EQ + GROOVE
When set, the following will be displayed.
4-7-2. Replase the Test Mode
1. Press the REPEAT key.
2. The set thus becomes available for normal operation.
2. The set thus becomes available for normal operation.
4-7-3.
Basic Operation of the Test Mode
•
All operations are performed using the MULTI JOG dial,
ENTER/YES key, and EDIT/NO key.
ENTER/YES key, and EDIT/NO key.
•
The functions of these keys are as follows.
Table 4-3.
Key
Contents
MULTI JOG dial
Changes parameters and models.
ENTER/YES key
Proceeds onto the next step.
Finalizes input.
Finalizes input.
EDIT/NO Key
Returns to previous step.
Stops operation.
Stops operation.
4-7-4. Selecting the Test Mode
Eight test modes are selectied by turning the MULTI JOG dial.
Table 4-4.
Display
Contents
TEMP
ADJUST
Temperature compensation offset
adjustment
adjustment
LDPWR ADJUST
Laser power adjustment
EFBAL
ADJUST
Traverse (E-F balance) adjustment
FBIAS
ADJUST
Focus bias adjustment
FBIAS
CHECK
Focus bias check
CPLAY MODE
Continuous playback mode
CREC
MODE
Continuous reading mode
EEP
MODE
Non-volatile memory mode (*1)
•
For detailed description of each adjustment mode, refer to sec-
tion 5. Electrical Adjustments.
tion 5. Electrical Adjustments.
•
If a different adjustment mode has been selected by mistake,
press the EDIT/NO key to exit from it.
press the EDIT/NO key to exit from it.
*1: The EEP MODE is not used in servicing. This mode reads and
writes the contents of the non-volatile memory. If set acciden-
tally, press the EDIT/NO key immediately to exit it.
tally, press the EDIT/NO key immediately to exit it.
4-7-5. Operating the Continuous Playback Mode
1. Entering the continuous playback mode
1) Set the disk in the unit (either MO or CD).
2) Turning the MULTI JOG dial and display “CPLAY MODE”.
3) Press the ENTER/YES key to change the display “CPLAY
2) Turning the MULTI JOG dial and display “CPLAY MODE”.
3) Press the ENTER/YES key to change the display “CPLAY
IN” .
4) When access cpmpletes, the display changes to
“C1 = AD = ”.
Note: The “
” displayed are arbitrary numbers.
2. Changing the parts to be played-back
1) Press the ENTER/YES key during continuous playback to
change the display to “CPLAY MID”, “CPLAY OUT”.
When pressed another time, the parts to be played-back can
be changed.
When pressed another time, the parts to be played-back can
be changed.
2) When access completes, the display changes to
“C1 = AD = ”.
Note: The “
” display are arbitrary numbers.
3. Ending the continuous playback mode
1) Press the EDIT/NO key. The display will change to “CPLAY
MODE”.
2) Press the
§(MD) key and remove the disc.
Notes:
1. The playback start addresses for IN, MID, and OUT are as
1. The playback start addresses for IN, MID, and OUT are as
follows.
IN: 40h cluster
MID: 300h cluster
OUT: 700h cluster
IN: 40h cluster
MID: 300h cluster
OUT: 700h cluster
2. The EDIT/NO KEY can be used to stop playing any time.
4-7-6.
Operating the Continuous Recording Mode
1. Entering the continuous recording mode
1) Set the MO disc in the unit.
2) Turning the MULTI JOG dial and display “CREC MODE”.
3) Press the ENTER/YES key to change the display to “CREC
2) Turning the MULTI JOG dial and display “CREC MODE”.
3) Press the ENTER/YES key to change the display to “CREC
IN”.
4) When access completes, the display changes to “CREC
( )” and
REC
lights up.
Note: The “ ” displayed are arbitrary humbers.
2. Changing the parts to recorded
2. Changing the parts to recorded
1) When the ENTER/YES key is pressed during continuous
recording, the display changes to “CREC MID”, “CREC
OUT” and
OUT” and
REC
goes off. When pressed another time, the
parts to be recorded can be changed.
2) When access completes, the display changes to “CREC
( )” and
REC
lights up.
Note: The “ ” displayed are arbitrary numbers.
3. Ending the continuous recording mode
1) Press the EDIT/NO key. The display will change to “CREC
MODE” and
REC
goes off.
2) Press the
§(MD) key and remove the disc.
Notes:
1. The recording start address for IN, MID, and OUT are as
follows.
IN
IN
: 40h cluster
MID : 300h cluster
OUT : 700h cluster
OUT : 700h cluster
M
T
B U
EM P
T e s t
A D J U
M o
S T
d e
– 18 –
2. The EDIT/NO key can be used to stop recording anytime.
3. During the test mode, the erasing-protection tab will not be
3. During the test mode, the erasing-protection tab will not be
detected. Therefore be carefull not to set the continuous re-
cording mode when a disc not be erased is set in the unit.
cording mode when a disc not be erased is set in the unit.
4. Do not perform continuous recording for long periods of
time above 5 minutes.
5. During continuous recording, be carefull not to apply vi-
bration.
4-7-7.
Function of other keys
table 4-5.
Centens
Key
Sets continuous playback when pressed in the
STOP state. (servo all on)
When pressed during continuous playback, the
tracking and sled servo turns off.
When pressed during tracking and sled servo
turned off, the turns on.
STOP state. (servo all on)
When pressed during continuous playback, the
tracking and sled servo turns off.
When pressed during tracking and sled servo
turned off, the turns on.
·(MD)
Stop continuous playback and continuous record-
ing. (servo all off)
ing. (servo all off)
The sled moves to the outer circumference only
when this is pressed.
when this is pressed.
π(MD)
)
The sled moves to the inner circumference only
when this is pressed.
when this is pressed.
0
Turns recording on/off when pressed during con-
tinuous playback.
tinuous playback.
r REC
Switches between the pit and groove modes when
pressed.
pressed.
TIME
CONTROL
CONTROL
Switches between the CLV-S (pull-in mode) and
CLV-A (playing servo) modes when pressed.
(Switches the spindle servo mode.)
CLV-A (playing servo) modes when pressed.
(Switches the spindle servo mode.)
PLAY
MODE
MODE
Switches the display when pressed.
Returns to previous step. Stops operatios.
Returns to previous step. Stops operatios.
DISPLAY
§(MD)
Disc eject
Note: The erasing-protection tab in not detected during the test
mode. Recording will start regardless of the position of the
erasing-protection tab when the
erasing-protection tab when the
r REC key is pressed.
MODE
display
Error rate
display
Address
display
1. MODE display
Display “TEMP ADJUST”, “CPLAY MODE”, etc.
2. Error rate display
Error rates are displayed as follows.
C1 = AD =
C1 = : Indicates C1 error
AD = : Indicates ADER
AD = : Indicates ADER
4-7-8.
Test Mode Displays
•
Each time the DISPLAY key pressed, the display changes in the
following order.
following order.
3. Address display
Address are displayed as follows.
h = s =
(MO pit and CD)
h = s =
(MO groove)
h = : Header address
s = : SUB Q address
a = : ADIP address
s = : SUB Q address
a = : ADIP address
Note: “—” is display when the address cannot be read.
– 19 –
4-7-10. Precautions for Use of Test Mode
1. As loading related operations will be performed regardless of
the test mode operations being performed, be sure to check that
the disc is stopped before setting and removing it.
Even if the
the disc is stopped before setting and removing it.
Even if the
§(MD) key is pressed while the disc is rotating
during continuous playback, continuous recording, etc., the disc
will not stop rotating.
Therefore, it will be ejected while rotating.
Always press the EDIT/NO key first before pressing the
§(MD) key.
will not stop rotating.
Therefore, it will be ejected while rotating.
Always press the EDIT/NO key first before pressing the
§(MD) key.
2. The erasing-protection tab is not detected in the test mode. There-
fore, when modes which output the recording laser power such
as continuous recording mode and traverse adjustment mode,
etc. are set, the recorded contents will be erased regardless of
the position of the tab. When using a disc that is not to be erased
in the test mode, be careful not to enter the continuous record-
ing mode and traverse adjustment mode.
as continuous recording mode and traverse adjustment mode,
etc. are set, the recorded contents will be erased regardless of
the position of the tab. When using a disc that is not to be erased
in the test mode, be careful not to enter the continuous record-
ing mode and traverse adjustment mode.
4-7-9.
Meanings of Other Displays
Table 4-6.
Display
Contents
Light
Off
Blinking
During continuous Stop state
(
playback
(servo all off)
(servo all on)
P
Tracking and
Tracking and
sled servo off
sled servo on
Recording mode Recording mode
on
on
off
SYNC
CLV lock state
CLV unlock state
TRACK
Pit mode
Groove mode
DISC
High reflection
Low reflection
rate disc
rate disc
LEVEL-
Spindle servo
Spindle servo
SYNC
CLV-S (pull-in
CLV-A (playing
mode)
mode)
PROGRAM
ABCD adjustment not adjustment
Completed
Completed
Focus auto gain
Focus auto gain
and tracking
successful,
SHUFFLE
auto gain
tracking auto
successful
gain failed
REC
– 20 –
SECTION 5
ELECTRICAL ADJUSTMENTS
5-3. PRECAUTIONS FOR ADJUSTMENTS
1) When replacing the following parts, perform the adjustments
and checks with
® in the order shown in the following table.
Optical
BD (MD) board
Pick-up
IC171
D101
IC101, IC121, IC191
1. Temperature
compensation
×
®
®
®
offset adjustment
2. Laser power
®
×
×
®
adjustment
3. Traverse
®
®
×
®
adjustment
4. Focus bias
®
®
×
®
adjustment
5. Error rate check
®
®
×
®
2) Set the test mode when performing adjustments.
After completing the adjustments, exit the test mode.
3) Perform the adjustments in the order shown.
4) Use the following tools and measuring devices.
4) Use the following tools and measuring devices.
•
Test disc (CD) TDYS-1
(Parts No. 4-963-646-01)
•
Laser power meter LPM-8001
(Parts No. J-2501-046-A)
•
Oscilloscope
•
Digital voltmeter
•
Thermometer
5) When observing several signals on the oscilloscope, etc., make
sure that VC and GND do not connect inside the oscilloscope.
(VC and GND will become short-circuited)
(VC and GND will become short-circuited)
5-4. Creating MO Continuously Recorded Disc
* This disc is used in focus bias adjustment and error rate check.
The following describes how to create a MO continuous record-
ing disc.
ing disc.
1. Set the test mode.
2. Insert a MO disc (blank disc) commercially available.
3. Turning the MULTI JOG dial and display “CREC MODE”.
4. Press the ENTER/YES key and display “CREC IN”.
5. Press the ENTER/YES key again to display “CREC MID”.
2. Insert a MO disc (blank disc) commercially available.
3. Turning the MULTI JOG dial and display “CREC MODE”.
4. Press the ENTER/YES key and display “CREC IN”.
5. Press the ENTER/YES key again to display “CREC MID”.
“CREC (0300)” is displayed for a moment and recording starts.
6. Complete recording within 5 minutes.
7. Press the EDIT/NO key and stop recording.
7. Press the EDIT/NO key and stop recording.
8. Press the
§ (MD) key and remove the MO disc.
The above has been how to create a continuous recording data for
the focus bias adjustment and error rate check.
Note:
the focus bias adjustment and error rate check.
Note:
•
Be careful not to apply vibration during continuous recording.
Note:
Be sure to connect all wires (including FFC) in the MD
section before applying power or ICs may be damaged.
Be sure to connect all wires (including FFC) in the MD
section before applying power or ICs may be damaged.
MD SECTION
5-1. PRECAUTIONS FOR CHECKING LASER DI-
ODE EMISSION
To check the emission of the laser diode during adjustments,
never view directly from the top as this may lose your eye-
sight.
never view directly from the top as this may lose your eye-
sight.
5-2. PRECAUTIONS FOR USE OF OPTICAL PICK-
UP (KMS-210A)
As the laser diode in the optical pick-up is easily damaged by
static electricity, solder the laser tap of the flexible board when
using it.
Before disconnecting the connector, desolder first. Before con-
necting the connector, be careful not to remove the solder.
Also tale adequate measures to prevent damage by static elec-
tricity. Handle the flexible board with care as it breaks easily.
static electricity, solder the laser tap of the flexible board when
using it.
Before disconnecting the connector, desolder first. Before con-
necting the connector, be careful not to remove the solder.
Also tale adequate measures to prevent damage by static elec-
tricity. Handle the flexible board with care as it breaks easily.
Optical pick-up flexible board
Laser tap