DOWNLOAD Sony DHC-MD333 / HCD-MD333 Service Manual ↓ Size: 6.92 MB | Pages: 88 in PDF or view online for FREE

Model
DHC-MD333 HCD-MD333
Pages
88
Size
6.92 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
dhc-md333-hcd-md333.pdf
Date

Sony DHC-MD333 / HCD-MD333 Service Manual ▷ View online

– 1 –
HCD-MD333
SPECIFICATIONS
SERVICE MANUAL
COMPACT DISC DECK RECEIVER
— Continued on next page —
US Model
Canadian Model
AEP Model
UK Model
E Model
Australian Model
Tourist Model
HCD-MD333 is the amplifier, CD, MD and
tuner section in DHC-MD333.
Model Name Using Similar Mechanism
NEW
Mechanism Type
CDM13C-5BD19
Base Unit Type
BU-5BD19
Optical Pick-up Type
KSS-213B/K-N
Model Name Using Similar Mechanism
NEW
Mechanism Type
MDM-3J
Optical Pick-up Type
KSM-260A-JIN
CD
SECTION
MD
SECTION
Ver 1.
2
  200
4
. 0
9
9-92
2
-93
5
-1
3
200
4I
02-1
© 200
4
.
09
Sony Corporation
Audio 
Group
Published by Sony Engineering Corporation
– 2 –
– 3 –
SELF-DIAGNOSIS FUNCTION
The self-diagnosis function consists of error codes for users which are displayed automatically when errors occur, and error codes which
show the error history in the test mode during servicing. For details on how to view error codes for users, refer to the following box  in the
instruction manual. For details on how to perform checks during servicing, refer to the following “Procedure for Using the Self-Diagnosis
Function (Error History Display Mode)”.
Procedure for Using the Self-Diagnosis Function (Error History Display Mode)
Note:
Perform the self-diagnosis function in the “error history display mode” in the test mode. The following describes the least required
steps. Be careful not to enter other modes by mistake. If other modes are set accidentally, press the  ^ (CD)  button to exit that
mode.
1. With the power off, press the  ^ (MD)  button while pressing the  PLAY MODE  button.
2. Rotate the  VOLUME  knob until “ERR DP MODE” is displayed.
3. Pressing the  p (CD)  button sets the error history mode and displays “total rec”.
4. Select the contents to be displayed or executed using the  VOLUME  knob.
5. Pressing the  6 (CD)  button displays or executes the contents selected.
6. Pressing the  6 (CD)  button another time returns to step 4.
7. Pressing the  ^ (CD)  button displays “ERR DP MODE” and exits the error history mode.
8. To exit the test mode, press the  REPEAT  button. The unit sets into the STANDBY state, and the test mode ends.
– 4 –
ITEMS OF ERROR HISTORY MODE ITEMS AND CONTENTS
Selecting the Test Mode
Display
total rec
total play
retry err
total err
err history
er refresh?
Details of History
No error
Disc error. Cannot read PTOC
(Disc is ejected out)
Disc error. UTOC error
(Disc is not ejected out)
Loading error
Cannot read address (Servo has deviated)
Displays the recording time in the form of “r
ππππππh”.
The displayed time is the total number of hours the laser is high power, which is about one-fourth of the actual
recording time. The time is displayed in decimal digits between 0h to 65535h.
Displays the playback time in the form of “p
ππππππh”.
The displayed time is the total actual play time. The paused time is not counted. The time is displayed in decimal
digits between 0h to 65535h.
Displays the total number of retries during recording and retry errors during playback in the form of “r
ππpππ”.
“r” indicates the retries during recording while “p” indicates the retry errors during playback. The number of
retries is displayed in hexadecimal digits between 00 to FF.
Displays the total number of errors in the form of “total 
ππ”.
The number of errors is displayed in hexadecimal digits between 00 to FF.
Displays the 10 latest errors in the form of “0
π E@@”.
The 
π indicates the history number. The smaller the number, the newer is the error. (00 is the latest error.)
The @@ indicates the error code. Refer to the following table for details. Rotate the  VOLUME  knob to  switch
the  error history.
Mode which erases all the error histories.
The error history serves as a reference for when to replace the optical pick-up. Perform this procedure when the
optical pick-up has been replaced in order to erase past error histories and not at other times. Press the  p (CD)
button when “er refresh??”  is displayed. The history will be erased and “Complete!” will be displayed momentarily.
Be sure to check the following when this mode has been executed.
• Check that the data has been erased.
• Perform recording and playback, and check that the mechanism operates normally.
Table of Error Codes
Error Code
E00
E01
E02
E03
E04
E05
E06
E07
E08
E09
E0A
FOK has deviated
Unfocused (Servo has deviated)
Recording retry
Recording retry error
Play retry error
(Access error)
Playback retry error (C2 error)
Details of Error
Error Code
Details of Error
Page of 88
Display

Sony DHC-MD333 / HCD-MD333 Service Manual ▷ Download

  • DOWNLOAD Sony DHC-MD333 / HCD-MD333 Service Manual ↓ Size: 6.92 MB | Pages: 88 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sony DHC-MD333 / HCD-MD333 in PDF for free, which will help you to disassemble, recover, fix and repair Sony DHC-MD333 / HCD-MD333 Audio. Information contained in Sony DHC-MD333 / HCD-MD333 Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.