DOWNLOAD Sony DAV-HDX275 / DAV-HDX277WC / DAV-HDX279W / DAV-HDX475 / DAVHDX576WF / DAV-HDX675 / HCD-HDX275 / HCD-HDX277WC / HCD-HDX279W / HCD-HDX475 / HCD-HDX576WF / HCD-HDX675 Service Manual ↓ Size: 5.95 MB | Pages: 110 in PDF or view online for FREE

Model
DAV-HDX275 DAV-HDX277WC DAV-HDX279W DAV-HDX475 DAVHDX576WF DAV-HDX675 HCD-HDX275 HCD-HDX277WC HCD-HDX279W HCD-HDX475 HCD-HDX576WF HCD-HDX675
Pages
110
Size
5.95 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
dav-hdx275-dav-hdx277wc-dav-hdx279w-dav-hdx475-dav.pdf
Date

Sony DAV-HDX275 / DAV-HDX277WC / DAV-HDX279W / DAV-HDX475 / DAVHDX576WF / DAV-HDX675 / HCD-HDX275 / HCD-HDX277WC / HCD-HDX279W / HCD-HDX475 / HCD-HDX576WF / HCD-HDX675 Service Manual ▷ View online

HCD-HDX275/HDX277WC/HDX279W/HDX475/HDX576WF/HDX675
25
DIGITAL  MEDIA  PORT  TEST
Procedure:
1.  Connect the DMPORT CHECK JIG (Part No.: J-2501-309-A) 
with the terminal DMPORT.
2.  Press the [
?
/
1
] button to turn the power on.
3. Confi rm that both LEDs of the DMPORT confi rmation  JIG 
lights. (Confi rmation the power supply line.)
4.  Set the [FUNCTION] button with “DMPORT” on this model.
5. Press 
the 
[
S
], [
l
] buttons and turn the [VOLUME] control 
in the direction of (+) simultaneously, the DMPORT test mode 
is activated.
6.  It is confi rmed that “DMPORT OK” is displayed on this set 
display. (Confi rmation of communication line)
7.  To a pinjack of the DMPORT confi rmation JIG input informa-
tion relevant to audio signal (sine-wave 1.0Vrms) and compos-
ite video signal (white 100% 1.0 Vp-p, color bar, etc.)
8. Confi rm the output of speakers and monitor TV. (Confi rmation 
of analog signal)
9.  To exit from this mode, press the [
S
], [
l
] buttons and turn 
the [VOLUME] control in the direction of (+).
color pattern
generator
DMPORT
check jig
(Part No.:
J-2501-309-A)
J001
AF oscillator
set
TV
monitor
FL/FR
speaker
MAIN board
CN204
SPEAKER board
TB100 (HDX275/HDX277WC/
      HDX475/HDX675)
TB101 (HDX279W/HDX576WF)
IO board
J402
1.  DVD  SERVICE  MODE  GENERAL  DESCRIPTION
This mode let you make diagnosis and adjustment easily by using 
the remote commander and the TV screen. The instructions, diag-
nostic results, etc. are given on the on-screen display.
Be sure to execute the IOP measurement when a base unit is re-
placed.
2.  ENTERING  DVD  SERVICE  MODE
Procedure:
1.  Press the [
?
/
1
] button to turn on the system.
2.  Press the [FUNCTION] button repeatedly to select the 
“DVD”.
3.  While pressing the [
s
] and [
A
] buttons simultaneously, turn 
[VOLUME] dial in the direction of (+) with the DVD player in 
power on.
4.  The message “SERVICE IN” appears on the fl uorescent  in-
dicator tube and top menu of the Remocon Diagnosis Menu 
appears on the on-screen display on the TV screen as follows. 
The model name, IF-con version and Syscon version are dis-
played at the bottom of the on-screen display.
 
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
Model Name 
:xxxx_xx
IF-con:Ver.xx.xx(xxxx)
Syscon:Ver.x.xxx
5.  To execute each function, press its number by using numeric 
button on the remote commander.
6.  To release from this mode, press the [
?
/
1
] button to turn off the 
system.
3.  EXECUTING  IOP  MEASUREMENT
In order to execute IOP measurement, the following standard pro-
cedures must be followed.
Procedure:
1.  From the top menu of Remocon Diagnosis Menu, select “2 
Drive Manual Operation” by pressing the [2] button on the 
remote commander. The following screen appears on the on-
screen display
 
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Mecha test mode
5. MIRR time Adjust
0. Return to Top Menu
2.  Select “3. Manual Adjustment” by pressing the [3] button on 
the remote commander. The following screen appears on the 
on-screen display.
 
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
[
V][v]  Change Value
[RETURN]Return to previous menu
3.  Select “6. Iop:” by pressing [6] button on the remote com-
mander.
4.  Wait until a hexadecimal number appear in the on-screen dis-
play as below.
 
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq boost Adjust:
6. Iop: ED:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
[
V][v]  Change Value
[RETURN]Return to previous menu
5.  Convert data from hexadecimal to decimal by using conver-
sion table.
DVD SECTION
Ver. 1.1
HCD-HDX275/HDX277WC/HDX279W/HDX475/HDX576WF/HDX675
26
6.  If the value is smaller than 93 (decimal), then it is OK. How-
ever if the value is higher than 93, then BU (base unit) is defec-
tive and need to be change.
7.  Press the [
O
 RETURN] button on the remote commander to 
return to previous menu.
8.  Press the [0] button on the remote commander to return to the 
top menu of Remocon Diagnosis Menu.
9.  Press the [
?
/
1
] button to turn off the system.
4.  CHECKING  EMERGENCY  HISTORY
To check the emergency history, please follow the following pro-
cedure.
Procedure:
1.   From the top menu of Remocon Diagnosis Menu, select “3. 
Emergency History” by pressing the [3] button on the remote 
commander. The following screen appears on the on-screen 
display.
 
Emg. History Check
Laser Hours     CD    999h  59min
                DVD   999h  59min
01. 01 05 04 04      00 92 46 00
    00 00 00 00      00 00 23 45
02. 02 02 01 01      00 A9 4B 00
    00 00 00 00      00 00 23 45
[Next]Next page [Prev]Prev page
[0]Return to Top Menu
2.  You can check the total time when the laser is turned on during 
playback of DVD and CD from the above menu. The maxi-
mum time, which can be displayed are 999h 59min.
3.  You can check the error code of latest 10 emergency history 
from the above menu. To view the previous or next page of 
emergency history, press the [
l
] or [
L
] button on the re-
mote commander. The error code consists of three kinds of er-
ror codes. 
A. Error code
 
Example of Error code
01. 01 05 04 04      00 92 46 00
    00 00 00 00      00 00 23 45
The meaning of error code is as below:
01: Communication error (No reply from syscon)
02: Syscon hung up
03: Power OFF request when syscon hung up
19: Thermal shutdown
24: MoveSledHome error
25: Mechanical move error (5 changer)
26: Mechanical move stack error
30: DC motor adjustment error
31: DPD offset adjustment error
32: TE balance adjustment error
33. TE sensor adjustment error
34. TE loop gain adjustment error
35. FE loop gain adjustment error
36. Bad jitter after adjustment
40. Focus NG
42. Focus layer jump NG
51: Spindle stop error
52. Open kick spindle error
60: Focus on error
61: Seek fail error
62: Read Q data/ID error
70: Lead in data read fail
71: TOC read time out (CD)
80: Can’t buffering
81: Unknown media type
B. Parameter of error code
This is the detail of error code. 
 
Example of Error code
01. 01 05 04 04      00 92 46 00
    00 00 00 00      00 00 23 45
C. Time of error code
This is the laser time when an error occurred.
 
Example of Error code
01. 01 05 04 04      00 92 46 00
    00 00 00 00      00 00 23 45
To Clear the Laser Hour
Press the [  DISPLAY] button on the remote commander and then 
press the [CLEAR] button on the remote commander. The data for 
both CD and DVD data are reset.
 
Emg. History Check
Laser Hours     CD      0h   0min
                DVD     0h   0min
01. 01 05 04 04      00 92 46 00
    00 00 00 00      00 00 23 45
02. 02 02 01 01      00 A9 4B 00
    00 00 00 00      00 00 23 45
[Next]Next page [Prev]Prev page
[0]Return to Top Menu
To Clear the Emergency History
Press the [DVD TOP MENU] button on the remote commander 
and then press the [CLEAR] button on the remote commander. The 
error code for all emergency history would be reset.
 
Emg. History Check
Laser Hours     CD    999h  59min
                DVD   999h  59min
01. 00 00 00 00      00 00 00 00
    00 00 00 00      00 00 00 00
02. 00 00 00 00      00 00 00 00
    00 00 00 00      00 00 00 00
[Next]Next page [Prev]Prev page
[0]Return to Top Menu
HCD-HDX275/HDX277WC/HDX279W/HDX475/HDX576WF/HDX675
HCD-HDX275/HDX277WC/HDX279W/HDX475/HDX576WF/HDX675
27
27
SECTION  5
ELECTRICAL  ADJUSTMENTS
When the base unit is replaced, perform the adjustment and the 
measurement as shown below in this order.
EXECUTING IOP MEASUREMENT (See page 25)
FM  TUNE  LEVEL  CHECK
signal
generator
set
Procedure:
1.  Turn on the set.
2.  Input the following signal from signal generator to FM antenna 
input directly.
Carrier frequency: A = 87.5 MHz, B = 98 MHz, C = 108 MHz
Deviation : 
75 
kHz
Modulation : 1 kHz
ANT input  : 35 dBu (EMF)
Note:  Use 75 ohm coaxial cable to connect signal generator and the set. 
You cannot use video cable for checking.
 
Use signal generator whose output impedance is 75 ohm.
3.  Set to FM tuner function and tune A, B and C signals.
4. Confi rm “TUNED” is lit on the display for A, B and C sig-
nals.
When the selected station signal is received in good condition, 
“TUNED” is displayed.
DVD  SECTION
TUNER  SECTION
To Execute the Initialize Setup Data
Procedure:
1.  Press the [DVD MENU] button on the remote commander and 
then press the [CLEAR] button on the remote commander. The 
following screen appears on the on-screen display.
Emg. History Check
Laser Hours     CD    999h  59min
                DVD   999h  59min
Initialize setup data...
[Next]Next page [Prev]Prev page
[0]Return to Top Menu
2.  The screen after a while returns to former display.
To Return to the Top Menu of  Remocon Diagnosis Menu
Press the [0] button on the remote commander.
5.  CHECKING  VERSION  INFORMATION
To check the version information, please follow the following pro-
cedure.
Procedure:
1.   From the top menu of  Remocon Diagnosis Menu, select “4. 
Version Information” by pressing the [4] button on the remote 
commander. The following screen appears on the on-screen 
display.
 
Version information
Firm(Main): Ver. X.XXXX
Firm(Sub): XX.XX
RISC: XXXXXX
8032: XXXXXX
Audio DSP: XX.XX.XX.XX
Servo DSP: XX.XX.XX.XX
[0]Return to Top Menu
2.  To return to the top menu of Remocon Diagnosis Menu, press 
the [0] on the remote commander.
HCD-HDX275/HDX277WC/HDX279W/HDX475/HDX576WF/HDX675
HCD-HDX275/HDX277WC/HDX279W/HDX475/HDX576WF/HDX675
28
28
SECTION  6
DIAGRAMS
6-1.  BLOCK  DIAGRAM  - RF SERVO/VIDEO Section -
DQ0 – DQ7
HD0 – HD7
A-1, A0 – A20
HA0 – HA21
OPTICAL PICK-UP
BLOCK
RF AMP, SERVO DSP,
MPEG DECODER,
HDMI TRANSMITTER
IC1101
FOCUS/TRACKING COIL DRIVE,
SPINDLE/SLED MOTOR DRIVE
IC1201
AUTOMATIC POWER
CONTROL (FOR CD)
Q1102-1
DVDRFIP
10
DVDA
6
DVDB
7
DVDC
8
DVDD
9
RF
MA
11
MB
12
MC
13
MD
14
VOA/A
VOB/B
VOC/C
VOD/D
TNI
17
VOE/E+G
TPI
18
VOF/F+H
V2O
28
VC
LDO1
22
LD (780)
AUTOMATIC POWER
CONTROL (FOR DVD)
Q1102-2
LDO2
21
LD (650)
FOO
41
CD ON
SWITCH
Q1101-1
DVD ON
SWITCH
Q1101-2
VR (780)
MSW
LIMITSW
54
52
53
VR (650)
FCS+
MSW
MDI1
19
MDI2
20
PD
LIMIT
Q1103
XROMCS
CE
SD-RAM
IC1104
X1101
27MHz
36
FCS–
37
1
TRO
40
TRK+
35
TRK–
34
4
FMO
37
SL+
29
SL–
30
10
DMO
36
SP+
27
SP–
28
31
32
41
46
47
13
OP_INP
35
45
BCK
ABCK
226
ALRCK
223
ACLK
225
79, 80,
82 – 86, 89
 29, 31, 33, 35,
38, 40, 42, 44
92, 77, 56 – 62, 74 – 67,
91, 63, 64, 75, 87
45, 25 – 18, 8 – 1,
48, 17, 16, 9, 10
DQ0 – DQ15
RD0 – RD15
A0 – A11
RA0 – RA11
 2, 4, 5, 7, 8, 10, 11, 13, 42,
44, 45, 47, 48, 50, 51, 53
121 – 119, 117 – 113,
129 – 122
140, 141, 143, 144,
155 – 150, 139, 149
23 – 26,
29 – 34, 22, 35
76
XT
ALI
239
26
XRD
OE
78
28
XWR
WE
66
11
RESET
12
BA0
BA0
137
20
BA1
BA1
138
21
DRCLK
CLK
146
38
CKE
CLKE
147
37
DQM0
LDQM
111
15
DQM1
UDQM
132
39
RAS
/RAS
135
18
CAS
/CAS
134
17
RCS
/CS
136
19
R
WE
/WE
133
DIR_DO
231
16
• SIGNAL PATH
: CD/DVD PLAY
: AUDIO
: VIDEO
FOCUS
COIL DRIVE
TRACKING
COIL DRIVE
SLED
MOTOR DRIVE
SPINDLE
MOTOR DRIVE
REGULATOR
MUTE123
MUTE123
157
19
MUTE
MUTE34
158
20
TSD_M
TSD-M
130
22
IOPMON
39
40
8
PS 21
BUFFER
BUFFER
RF+3.3V
SDA
SDA
102
5
SCL
SCL
101 112
6
EEWP
WE
7
REGO2
REGO1
DVD_SOD
IFSDO
32
97
DVD XIFCS
xIFCS
37
99
51
DVD_SID
IFSDI
31
M_ST
52
100
DVD_SCO
IFSCK
33
98
DVD_XIFBUSY
IFBSY
34
110
MTK_RST
XSYSRST
38
V_SEL1
83
108
SYSTEM CONTROLLER
IC501 (1/5)
LRCK
MCK
D2
D3
D1
189
C
191
Y
183
B/Cb/Pb
185
Y/G
182
R/Cr/Pr
VIDEO AMP, 75
 ohm DRIVER
IC404
10 CY IN
12 Cb IN
14 Cr IN
4 CVBS IN
2 C IN
6 Y IN
3
MUTE1
13
MUTE2
5
YC_MIX
V_SEL0
82
KHM-310CAB
or
KHM-313CAB
J404
COMPONENT
VIDEO OUT
Y
P
B
/C
B
P
R
/C
R
J402 (1/2)
23
CVBS OUT
20
CY OUT
18
Cb OUT
16
Cr OUT
VIDEO OUT
FLASH ROM
IC1102
EEPROM
IC1103
XT
ALO
238
A
AUDIO_BUS
HDMI_BUS
D-2
D-4
C
D
F
XRST
204
ASDATA2
205
ASDATA1
203
ADIN(DATA)
DIR_AUDIO
202
ASDATA0
ASDATA3
DMPORT_VIDEO
(HCD-HDX576WF)
(EXCEPT HCD-HDX576WF)
E
V_SEL2
TX0P
TX0N
TX1P
TX1N
TX2P
TX2N
TCKP
TCKN
HTPLG
174
173
177
176
179
171
170
DDC_DA
DDC_CLK
TX0P
TX0N
TX1P
TX1N
TX2P
TX2N
TCKP
TCKN
HPD
SDA
SCL
159
161
MC_DATA(ADIN) 206
162
180
222
BUFFER
IC4502
AUDIO SELECTOR
IC3003
1 A
2 B
6
A/B
5
Y
B
VinL
14
13
VinR
BCK
7
LRCK
6
8
SCKI
A/D CONVERTER
IC707
9 DOUT
M
AUDIO1
R-CH
DIGITAL AUDIO
INTERFACE RECEIVER
IC702
DO (O)
35 36
DI (I)
CL
 (I)
38
CE (I)
37
14
BCK (O)
LRCK (O)
15
CKOUT
 (O)
13
CSFLAG (O)
25
ERROR (O)
34
XST
ATE (O)
17
XMODE (I)
48
DIR_DI
230
DIR_CL
227
DIR_CE
221
SPBCK
200
SPLRCK
201
SPMCK
198
DIR_CSFLAG
214
DIR_ERROR
DIR_XST
ATE
198
5
DIN2 (I)
OPTICAL
RECEIVER
IC301
TV
DIGITAL IN
OPTICAL
TV
DIGITAL IN
COAXIAL
TV/VIDEO
DIGITAL IN
OPTICAL
TV/VIDEO
DIGITAL IN
COAXIAL
J302
4
DIN1 (I)
WAVE
SHAPER
IC302
XIN (I)
22
XOUT
 (O)
21
X701
12.288MHz
16 DATA (O)
24 AUDIO- (O)
(Page 31)
(Page 30)
(Page 29)
(Page 30)
(Page 29)
(Page 29)
(Page 29)
Page of 110
Display