25
HCD-FX999W/FX1000W
4-5. EXECUTING IOP MEASUREMENT
In order to execute mirror time adjustment, the following standard
procedures must be followed.
(1) In standby mode, press three buttons  x  ,  A  and
 VOLUME +  simultaneously.
*1 In HCD-FX999W, “GC7GW***” is displayed.
Ver. 1.1
MIRR time Adjust Menu
1. CD MIRR time check:  YY  YY
2. DVD MIRR time check:  XX  XX
3. Threshold:
4. Save to EEPROM:
5. Default set MIRR time:
[Open] Tray open [close] Tray close
[0] Return to previous menu
(2) Select “2. Drive Manual Operation” by pressing the  2 “R”
button on the remote commander. The screen will appear as
     below.
(3) Select “3. Manual Adjustment” by pressing the  3 “R”  button
on the remote commander. The screen will appear as below.
(4) Select Iop by pressing  6 “R”  button on the remote commander.
(5) Wait until a hexadecimal number appear.
(6) Convert each data from hexadecimal to decimal using
      conversion table.
(7) Substract between these two values.
(8) If the remainder is smaller than 93 (decimal), then it is
      OK. However if the value is higher than 93, then the BU
      is defective and need to be change.
(9)  Press  ORETURN “R”  button to return back to previous
 menu.
(10) Press  0 “R”  button to return to Top Menu and power OFF
the DVD Player.
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop. ED 9E:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
Change Value
[0] Return to previous menu
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History Check
4. Version information
5. Video Level Adjustment
Model
: GC7GHW    XX
IF-con  Ver
: XX.XX (XXXX)
Syscon  Ver : X.XX
*
1
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
5. MIRR time adjust
0. Return to top Menu
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
o
  O    Change Value
[RETURN] Return to previous menu
(23) Push  A  button to eject tray.
(24) Remove Test Disc YEDS-18 from tray.
(25) Push  A  button to close tray.
(26) Press  0 “R”  button to the Drive Manual Operation menu.
(27) Press  0 “R”  button to return to the Remocon Diagnosis
Menu.
(28) Press the  ?/1  button to switch OFF set.
(22) Confirm the same values are displayed. If it is not the
        same, return to step 15.
(23) Push  A  button to eject tray.
(24) Remove Test Disc YEDS-18 from tray.
(25) Push  A  button to close tray.
(26) Press  0 “R”  button to the Drive Manual Operation menu.
(27) Press  0 “R”  button to return to the Remocon Diagnosis
Menu.
(28) Press the  ?/1  button to switch OFF set.
26
HCD-FX999W/FX1000W
2. Component Output Level Adjustment (MIB01 Board)
<Purpose>
This adjusts component output level. If it is incorrect, correct
brightness will not be attained when connected to, for instance,
projector.
Mode
Video level adjustment in test mode
Signal
Color bar 100% (HLX-504 Track1)
Test point
COMPONENT VIDEO OUT (Y)
connector (75 
 terminated)
Instrument
Oscilloscope
Adjusting element
RV502
Specification
1.0 Vp-p
DIAT SECTION
DIAT SIGNAL RF LEVEL  ADJUSTMENT
This adjustment is performed in order to adjust the transmission
distance of RF signal for DIAT communication.
Connection:
Procedure:
1. Connect the oscilloscope to TP815 and GND on the TX board.
2. Connect DIR-T1 to  DIR-T1  jack (I/O board: J602).
3. Adjust RV801 on the TX board so that the center of waveform
becomes 1.0 Vp-p.
4. Confirm trigger is locked.
5. Adjust RV801 on the TX board so that the center of waveform
becomes 2.2 to 2.4 Vp-p.
RF Signal Reference Waveform
SECTION 6
ELECTRICAL  ADJUSTMENT
VOLT/DIV : 500 mV
TIME/DIV : 500 ns
level : 2.2 to 2.4 Vp-p 
TP815
TX board
oscilloscope 
– TX Board (SIDE A) –
TP815
RV801
Adjustment Location:
HDMI SECTION
*For HCD-FX1000W only
ADJUSTMENT OF VIDEO SYSTEM
[TEST DISC LIST]
Use the following test disc on this mode.
• HLX-504 (NTSC Test Disc 504): J-6090-088-A
Connection:
1. Composite Level Adjustment (MIB01 Board)
<Purpose>
This adjustment is made to satisfy the standard, and if not adjusted
correctly, the brightness will be too large or small.
Mode
Video level adjustment in test mode
Signal
Color bar 100% (HLX-504 Track1)
Test point
MONITOR OUT (VIDEO) connector
(75 
 terminated)
Instrument
Oscilloscope
Adjusting element
RV501
Specification
1.0 Vp-p
Procedure:
1. Terminate the MONITOR OUT (VIDEO) connector in 75 
.
2. Connect an oscilloscope across 75 
 terminator.
3. Turn the power on.
4. Set the test disc (HLX-504) on the tray and press  
H
  button
to playback.
5. Confirm that oscilloscope waveform is clear and check
composite output level is correct or not.
6. If it is not correct, adjust the RV501 to attain 1.0 Vp-p.
MONITOR OUT (VIDEO)
COMPONENT VIDEO OUT (Y)
Set Back Panel
oscilloscope 
75 
1.0 Vp-p 
Ver. 1.1
27
HCD-FX999W/FX1000W
RV501
RV502
– MIB01 Board (SIDE A) –
1.0 Vp-p 
Ver. 1.3
Procedure:
1. Terminate the COMPONENT VIDEO OUT (Y) connector in
75 
.
2. Connect an oscilloscope across 75 
 terminator.
3. Turn the power on.
4. Set the test disc (HLX-504) on the tray and press  
H
  button
to playback.
5. Confirm that oscilloscope waveform is clear and check
component output level is correct or not.
6. If it is not correct, adjust the RV502 to attain 1.0 Vp-p.
Adjustment Location:
DVD SECTION
When the base unit is replaced, perform the adjustment and the
measurement as shown below in this order.
1) MIRROR TIME ADJUSTMENT (See page 23)
2) EXECUTING IOP MEASUREMENT (See page 25)
[TEST DISC LIST]
Be sure to use the DVD disc that matches the signal standards of
your region.
• 
CD
YEDS-18 (Part No.: 3-702-101-01)
PATD-012 (Part No.: 4-225-203-01)
• DVD SL (Single Layer)
NTSC : HLX-503 (Part No.: J-6090-069-A)
HLX-504 (Part No.: J-6090-088-A)
PAL    : HLX-506 (Part No.: J-6090-077-A)
• DVD DL (Dual Layer)
NTSC : HLX-501 (Part No.: J-6090-071-A)
HLX-505 (Part No.: J-6090-089-A)
PAL    : HLX-507 (Part No.: J-6090-078-A)
Procedure:
1. Conect an oscilloscope to CN105 pin 6 (RFMON) and CN105
pin 3 (GND) on the DMB10 board.
2. Turn the power on.
3. Insert the CD test disc (refer to the TEST DISC LIST), and
press the  H  button to play the disc back.
4. Confirm that oscilloscope waveform is clear and check RF
signal level is correct or not.
Note: 
A clear RF signal waveform means that the shape “
” can be
clearly distinguished at the center of the waveform.
5. Eject the CD disc, and insert the DVD SL test disk (refer to the
TEST DISC LIST), and press the  H button to play the disc
back.
Checking Location: DMB10 board (Side A)
+
CN105 pin 
6
 (RFMON)
CN105 pin 
3
 (GND)
oscilloscope 
DMB10 board
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
RF signal waveform
level: 0.57 
±
 1.1 Vp-p (CD)
          0.58 
±
 1.23 Vp-p (DVD)
IC102
IC101
IC104
IC201
CN105
CN106
CN105 pin 
3
 (GND)
CN105 pin 
6
 (RFMON)
1
6
[RF Level Check]
Connection:
28
HCD-FX999W/FX1000W
SECTION 7
DIAGRAMS
For Schematic Diagrams.
Note:
• All capacitors are in 
µ
F unless otherwise noted.  (p: pF)
50 WV or less are not indicated except for electrolytics and
tantalums.
• All resistors are in 
  and 
1
/
4
 
W or less unless otherwise
specified.
f
: internal component.
C
: panel designation.
THIS NOTE IS COMMON FOR PRINTED WIRING BOARDS AND SCHEMATIC DIAGRAMS.
(In addition to this, the necessary note is printed in each block.)
H
: adjustment for repair
A
: B+ Line.
B
: B– Line.
• Voltages and waveforms are dc with respect to ground un-
der no-signal (detuned) conditions.
• Voltages and waveforms are dc with respect to ground in
service mode.
• Waveforms are taken with a oscilloscope.
Voltage variations may be noted due to normal production
tolerances.
no mark : DVD STOP
• Voltages are taken with VOM (Input impedance 10 M
).
• Circled numbers refer to waveforms.
• Signal path.
F
: AUDIO
J
: CD PLAY
c
: DVD PLAY
I
: SACD PLAY
d
: TUNER
L
: VIDEO
E
: Y
a
: CHROMA
r
: COMPONENT VIDEO
f
: AUDIO IN
h
: DIGITAL IN (OPTICAL IN)
: DIGITAL
: DIGITAL OUT
N
: MIC
• Abbreviation
AUS
: Australian model
E3
: 240V AC area in E model
E13
: 220-230V AC area in E model
E32
: 110-240V AC area in E model
MX
: Mexican model
SP
: Singapore model
TW
: Taiwan model
For Printed Wiring Boards.
Note:
X
: parts extracted from the component side.
•        
a
: Through hole.
: Pattern from the side which enables seeing.
(The other layers' patterns are not indicated.)
• Indication of transistor.
Caution:
Pattern face side:  Parts on the pattern face side seen from
(SIDE A)               the pattern face are indicated.
Parts face side:     Parts on the parts face side seen from
(SIDE B)               the parts face are indicated.
C E
B
These are omitted 
C
B
These are omitted.
E
Q
Note: The components identified by mark 
0
 or dotted
line with mark 
0
 are critical for safety.
Replace only with part number specified.
Ver. 1.2
Page of 125
Display

Click on the first or last page to see other DAV-FX1000W / DAV-FX999W / HCD-FX1000W / HCD-FX999W service manuals if exist.