DOWNLOAD Sony DAV-DZ970WA / HCD-DZ970WA Service Manual ↓ Size: 5.42 MB | Pages: 104 in PDF or view online for FREE

Model
DAV-DZ970WA HCD-DZ970WA
Pages
104
Size
5.42 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
dav-dz970wa-hcd-dz970wa.pdf
Date

Sony DAV-DZ970WA / HCD-DZ970WA Service Manual ▷ View online

HCD-DZ970WA
21
SECTION  4
TEST  MODE
Note: Incorrect operations may be performed if the test mode is not 
entered properly.
 
In this case, press the [?/1] button to turn the power off, and 
retry to enter the test mode.
1. Cold Reset
•  The cold reset clears all data including preset data stored 
in the RAM to initial conditions. Execute this mode when 
returning the set to the customers.
Procedure:
1.  Press the [
?/1
] button to turn the power on. 
2.  Press three buttons [
x
], [
A
] and [
?/1
] simultaneously.
3.  When this button is operated, display as “COLD RESET” for 
a while and all of the settings are reset. 
2.  Panel Test Mode
•  This mode is used to check the software version, FL and 
KEY.
2-1.  Display Test Mode
Procedure:
1.  Press the [
?/1
] button to turn the power on.
2.  Press three buttons [
X
], [
.
] and [
A
] simultaneously.
3.  When the display test mode is activated, all segments are turned 
on.
4.   To exit from this mode, press three buttons [
X
], [
.
] and [
A
simultaneously.
2-2.  Version Test Mode
Procedure:
1.  When the display test mode is activated, press the [
.
] button 
and the message “DSR9KDWC” is displayed, the version test 
mode is activated.
2.  Whenever the [
.
] button is pressed, the display changes in 
the following order.
 
 
“DSR9KDWC” (Model name) U“RU
*1
” (Destination) U
UMC Version U SYS Version UUI Version U
UDVD Version UST Version U TA Version U
UDSP Version UTM Version UMM Version U
U CLA Version UCEC Version USAIR Version
 
 
*1: RU changes depending on destination.
3.  Press the [
>
] button and the date of the software production 
is displayed.
4.  Press the [
>
] button again and the version is displayed.
5.  To exit from this mode, press three buttons [
X
], [
.
] and [
A
simultaneously.
2-3.  Key Test Mode
Procedure:
1.  When the display test mode is activated, press the [
H
] button, 
to select the key test mode.
2.  To enter the KEY test mode, the fl uorescent indicator displays 
“K0 V0”. Each time an another button is pressed, “KEY” value 
increases. However, once a button is pressed, it is no longer 
taken into account. When all keys are pressed correctly, “K8 
V0” is displayed.
3.  When the [VOLUME] control is turned in the direction of (+), 
“V0” is changed to “V1”, then ... “V9”.
 
When the [VOLUME] control is turned in the direction of (–), 
“V0” is changed to “V9”, then ... “V1”.
4.   To exit from this mode, press three buttons [
X
], [
.
] and [
A
simultaneously.
3.  Disc Tray Lock
The disc tray lock function for the antitheft of an demonstration 
disc in the store is equipped.
Setting Procedure :
1.  Press the [
?/1
] button to turn the set on.
2.  Press the [FUNCTION] button to set DVD function.
3.  Insert a disc.
4. Press 
the 
[
x
] button and the [
A
] button simultaneously for fi ve 
seconds.
5.  The message “LOCKED” is displayed and the tray is locked.
Releasing Procedure :
1. Press 
the 
[
x
] button and the [
A
] button simultaneously for fi ve 
seconds again.
2.  The message “UNLOCKED” is displayed and the tray is 
unlocked.
Note: When “LOCKED” is displayed, the tray lock is not released by 
turning power on/off with the [?/1] button.
4.  DVD Ship Mode
Use this mode when returning the set to the customer after repair.
Procedure:
1.   Press the [
?/1
] button to turn the set on.
2.   Press the [FUNCTION] button to set the function “DVD”.
3.   Remove all discs, and then press two buttons [
H
] and [
?/1
simultaneously.
4.   After a message “MECHA LOCK” h “PULL PLUG” is 
displayed on the fl uorescent indicator tube, pull out the AC 
plug.
5.  To exit from this mode, press the [
?/1
] button to turn the set 
on.
5.  Product Out
This mode moves the optical pick-up to the position durable to 
vibration and clears all data including preset data stored in the 
RAM to initial conditions. Use this mode when returning the set to 
the customer after repair.
Procedure:
1.  Press the [
?/1
] button to turn the power on.
2.  Press the [FUNCTION] button to set the function “DVD”.
3.  Remove all discs, and then press three buttons [
>
], [
A
] and  
[
?/1
] simultaneously.
4.  After the “STANDBY” blinking display fi nishes, the message  
“MECHA LOCK” h “PULL PLUG” is displayed on the 
fl uorescent indicator tube disconnect the AC power plug, then 
the ship mode is set.
HCD-DZ970WA
22
DVD  SECTION
6-1.  GENERAL  DESCRIPTION
The IOP measurement allows you to make diagnosis and 
adjustment simply by using the remote commander and monitor 
TV. The instructions, diagnosis results, etc. are given on the on-
screen display (OSD).
Be sure to execute the IOP measurement when a BU (Base Unit) 
is replaced.
6-2.  HOW  TO  ENTER  TEST  MODE
While pressing the [
x
] and [
A
] buttons simultaneously, turn 
[VOLUME] control in the direction of (+) with the DVD player 
in power on.
The Test Mode starts, displayed “SERVICE IN” on this model 
display then the menu shown below will be displayed on the TV 
screen.
The menu above is the Remocon Diagnosis Menu screen which 
consists of fi ve main functions. At the bottom of the menu screen, 
the model name and IF-con version. To exit from the Test Mode, 
press the power button on the remote commander.
6-3.  EXECUTING  IOP  MEASUREMENT
In order to execute IOP measurement, the following standard 
procedures must be followed.
(1) In power on, while pressing the [
x
] and [
A
] buttons 
simultaneously, turn the [VOLUME] control in the direction 
of (+).
(2)  Select “2. Drive Manual Operation” by pressing the [2] button 
on the remote commander. The screen will appear as shown.
(3)  Select “3. Manual Adjustment” by pressing the [3] button on 
the remote commander. The screen will appear as shown.
(4)  Select “6. IOP” by pressing the [6] button on the remote 
commander.
(5)  Wait until a hexadecimal number appear.
(6) Convert each data from hexadecimal to decimal using 
conversion table.
(7) Please fi nd the label on the rear of the BU (Base Unit).
 
The default IOP value is written in the label.
(8)  Subtract between these two values.
(9)  If the remainder is smaller than 93 (decimal), then it is OK. 
However if the value is higher than 93, then the BU is defective 
and need to be change.
(10) Press the [RETURN] button on the remote commander to 
return back to previous menu.
(11) Press the [0] button on the remote commander to return to Top 
Menu.
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
Model Name
IF-con
: Ver. XX.XX (XXXX)
Syscon
: Ver. X.XXX
: DSR9KDWC_XX
*
1
*1: Changes depending on destination 
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
Model Name
IF-con
: Ver. XX.XX (XXXX)
Syscon
: Ver. X.XXX
: DSR9KDWC_XX
*1: Changes depending on destination 
*
1
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
5. MIRR time adjust
0. Return to Top Menu
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
0 P  Change Value
[RETURN] Return to previous menu
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop. 51:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
[RETURN] Return to previous menu
0 P  Change Value
HCD-DZ970WA
23
6-4.  EMERGENCY  HISTORY
To check the emergency history, please follow the following 
procedure.
(1) From the Top Menu of Remocon Diagnosis Menu, select “3. 
Emergency History Check” by pressing the [3] button on the 
remote commander. The following screen appears on the on-
screen display.
(2)  You can check the total time when the laser is turned on during 
playback of DVD and CD from the above menu. The maximum 
time, which can be displayed are 999h 59min.
(3) You can check the error code of latest 10 emergency history 
from the above menu. To view the previous or next page of 
emergency history, press [
.
] or [
>
] button on the remote 
commander. The error code consists of the following three 
blocks. The fi rst block indicates the error code. The second 
block indicates the parameter and the third block indicates the 
time of error code as shown below.
• Error Code
 
*1 : Error Code
 
*2 : Parameter of error code
 
*3 : Time of error code
 
The meaning of error code is as below:
 
01:   Communication error (No reply from syscon)
 
02:   Syscon hung up
 
03:   Power OFF request when syscon hung up
 
19:   Thermal shutdown
 
24:   MoveSledHome error
 
25:   Mechanical move error (5 Changer)
 
26:  Mechanical move stack error
 
30:   DC motor adjustment error
 
31:   DPD offset adjustment error
 
32:   TE balance adjustment error
 
33:   TE sensor adjustment error
 
34:   TE loop gain adjustment error
 
35:   FE loop gain adjustment error
 
36:   Bad jitter after adjustment
 
40:   Focus NG
 
42:   Focus layer jump NG
 
52:   Open kick spindle error
 
51:   Spindle stop error
 
60:   Focus on error
 
61:   Seek fail error
 
62:   Read Q data/ID error
 
70:   Lead in data read fail
 
71:  TOC read time out (CD)
 
80:   Can’t buffering
 
81:   Unknown media type
6-4-1.  Clear the Laser Hour
Press [  DISPLAY] button and then press [CLEAR] button on 
the remote commander. The data for both CD and DVD data are 
reset.
6-4-2.  Clear the Emergency History
Press [DVD TOP MENU]  button and then press [CLEAR] button 
on the remote commander. The error code for all emergency history 
would be reset.
6-4-3.  Clear the Initialize Setup Data
Press [DVD MENU] button and then press [CLEAR] button on the 
remote commander.
Emg. History Check
01.  01  05  04  04
Laser Hours
CD
999h
59min
DVD
999h
59min
00  92  46  00
00  00  00  00
00  00  23  45
02.  02  02  01  01
00  A9  4B  00
00  00  00  00
00  00  23  45
[Next]   Next Page    [Prev]  Prev Page
[O]  Return to Top Menu
Emg. History Check
01.  01  05  04  04
Laser Hours
CD
999h
59min
DVD
999h
59min
00  92  46  00
00  00  00  00
00  00  23  45
02.  02  02  01  01
00  A9  4B  00
00  00  00  00
00  00  23  45
[Next]   Next Page    [Prev]  Prev Page
[O]  Return to Top Menu
*
1
*
2
*
3
Emg. History Check
01.  01  05  04  04
Laser Hours
CD
0h
0min
DVD
0h
0min
00  92  46  00
00  00  00  00
00  00  23  45
02.  02  02  01  01
00  A9  4B  00
00  00  00  00
00  00  23  45
[Next]   Next Page    [Prev]  Prev Page
[O]  Return to Top Menu
01.  00  00  00  00
Laser Hours
CD
999h
59min
DVD
999h
59min
00  00  00  00
00  00  00  00
00  00  00  00
02.  00  00  00  00
00  00  00  00
00  00  00  00
00  00  00  00
[Next]   Next Page    [Prev]  Prev Page
[O]  Return to Top Menu
Emg. History Check
Emg. History Check
initialize setup data...
Laser Hours
CD
999h
59min
DVD
999h
59min
[Next]   Next Page    [Prev]  Prev Page
[O]  Return to Top Menu
HCD-DZ970WA
24
6-4-4. Return to the Top Menu of Remocon Diagnosis 
Menu
Press [0] button on the remote commander.
• Check Version Information
To check the version information, please follow the following 
procedure.
(1) From the Top Menu of Remocon Diagnosis Menu, select “4. 
Version Information” by pressing the [4] button on the remote 
commander. The following screen appears on the on-screen 
display.
 
To return to the Top Menu of Remocon Diagnosis Menu, press  
[0] button on the remote commander.
6-5.  AUTOMATIC  ACOUSTIC  FIELD  CALIBRATION 
 
  MICROPHONE  TEST  MODE
Procedure:
1.  Press the [
?/1
] button to turn the power on.
2.  Press the [FUNCTION] button to set the function “ DVD”.
3.  Insert ECM-AC2 supplied as an accessory into the AUDIO IN/
A.CAL MIC jack.
4.  While pressing the [
X
] and [
A
] buttons simultaneously, turn 
the [VOLUME] control in the direction of (+).
5. Confi rm that the following are shown on the display panel.
1
  The JACK inserted/non-inserted detection display and the 
STEREO/MONO detection display.
6.  To exit from this mode, press the [
X
] and [
A
] buttons simulta-
neously, turn the [VOLUME] control in the direction of (+).
7.  DEMO  PLAY  OUT
It is a mode to release the demonstration reproduct by the dedicated 
demonstration disc.
1.  During playback the DEMO Disc, press the [
x
] and [
H
buttons for fi ve seconds simultaneously.
2.  The message “DEMO OFF” is displayed, a mode to reproduct 
the demonstration is released.
8.  DIGITAL  MEDIA  PORT  TEST
1.  Connect the DMPORT CHECK JIG (P/N: J-2501-309-A) with 
the terminal DMPORT.
2.  Press the [
?/1
] button to turn the power on.
3. Confi rm that both LEDs of the DMPORT confi rmation  JIG 
lights. (Confi rmation the power supply line.)
4.  Set the [FUNCTION] button with “DMPORT” on this model.
5.  Press the [
X
], [
.
] buttons and turn the [VOLUME] control 
in the direction of (+) simultaneously, the DMPORT test mode 
is activated.
6. It is confi rmed that “DMPORT OK” is displayed on this set 
display. (Confi rmation of communication line)
7.  To a pin jack of the DMPORT confi rmation JIG input 
information relevant to audio signal (sine-wave 1.0Vrms) and 
composite video signal (white 100% 1.0Vp-p, color bar, etc.) 
8. Confi rm the output of speakers and monitor TV. (Confi rmation 
of analog signal)
9.  To exit from this mode, press the [
X
], [
.
] buttons and turn 
the [VOLUME] control in the direction of (+).
Version information
[O]  Return to Top Menu
Firm (Main) :  Ver. xxxxx
Firm (Sub) :  xxxxx
RISC :   xxxxx
8032  :   xxxxx
Audio DSP :  xxxxx
Servo DSP :  xxxxx
color pattern
generator
DMPORT 
CHECK JIG 
(P/N: J-2501-309-A)
MAIN
board
TV
CN204
J404
J001 7
AF oscillator
FL speaker, 
FR speaker
IO-COMPONENT
board
SPEAKER
board
TB100
VIDEO
AUDIO
SET
   
  “NON”  : Not detected
 “ST”  : 
STEREO
 “MONO” 
MONO
JACK
Page of 104
Display