DOWNLOAD Sony DAV-DZ810W / HCD-DZ810W Service Manual ↓ Size: 13.15 MB | Pages: 100 in PDF or view online for FREE

Model
DAV-DZ810W HCD-DZ810W
Pages
100
Size
13.15 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
dav-dz810w-hcd-dz810w.pdf
Date

Sony DAV-DZ810W / HCD-DZ810W Service Manual ▷ View online

21
HCD-DZ810W
3-14. OPTICAL PICK-UP (KHM-310CAA)
1
two claws
3
two claws
2
 chuck cam
4
 base unit 
5
two claws
7
bu holder
8
two insulators 
9
two insulators
6
four insulator screws
0
optical pick-up 
     (KHM-310CAA) 
22
HCD-DZ810W
SECTION  4
TEST MODE
Note 1:
Regarding the notification symbol “R”
Because the number of the operating buttons of this product
are limited, some operations require use of the operating
buttons of the remote commander, When a specific operation
requires use of the operating buttons of the remote
commander, “R” is added to the specific operating procedure
in this manual. Example  MENU/NO  “R”  The  MENU/NO
button of remote commander.
Note 2:
Incorrect operations may be performed if the test mode is
not entered properly.
In this case, press the  ?/1  button to turn the power off, and
retry to enter the test mode.
3. Disc Tray Lock
The disc tray lock function for the antitheft of an demonstration
disc in the store is equipped.
Setting Procedure :
1. Press the  ?/1  button to turn the set on.
2. Press the  FUNCTION  button to set DVD function.
3. Insert a disc.
4. Press the  
x  
button and the  A  button simultaneously for five
seconds.
5. The message “LOCKED” is displayed and the tray is locked.
Releasing Procedure :
1. Press the  
x  
button and the  A  button simultaneously for five
seconds again.
2. The message “UNLOCKED” is displayed and the tray is
unlocked.
Note:
When “LOCKED” is displayed, the slot lock is not released by
turning power on/off with the  ?/1  button.
4. DVD Ship Mode
Use this mode when returning the set to the customer after
repair.
Procedure:
1. Press the  ?/1  button to turn the set on.
2. Press the  FUNCTION  button to set the function “DVD”.
3. Remove all discs, and then press two buttons  x  and   .
simultaneously.
4. After a message “MECHA LOCK” is displayed on the
fluorescent indicator tube, pull out the AC plug.
5. To exit from this mode, press the  ?/1  button to turn the set on.
5. AM Step Change
A step of AM channels can be changed over between 9 kHz
and 10 kHz.
Procedure:
1. Press the  ?/1  button to turn the set ON.
2. Select the function “TUNER”, and press  FUNCTION  button
to select the BAND “AM”.
3. Press the  ?/1  button to turn the set OFF.
4. Press two buttons  >  and  ?/1  simultaneously, and the
display of fluorescent indicator tube changes to “AM 9 k
STEP” or “AM 10 k STEP”, and thus the channel step is
changed over.
6. Volume Test Mode
Procedure:
1. Press the  ?/1  button to turn the power on.
2. Press three buttons  . ,  H and  >  simultaneously.
3. The message “VOLUME MAX” is displayed, when the
VOLUME  control is turned in the dirction of (+).
The message “VOLUME MIN” is displayed, when the
VOLUME  control is turned in the dirction of (–).
4. To exit from this mode, press the  ?/1  button to turn the set off.
7. Product Out
This mode moves the optical pick-up to the position durable to
vibration and clears all data including preset data stored in the RAM
to initial conditions. Use this mode when returning the set to the
customer after repair.
Procedure:
1. Press the  ?/1  button to turn the power on.
2. Press the  FUNCTION  button to set the function “DVD”.
3. Remove all discs, and then press three buttons  > ,  A  and
?/1  simultaneously.
4. After the “STANDBY” blinking display finishes, the message
“MECHA LOCK” is displayed on the fluorescent indicator
tube disconnect the AC power plug, then the ship mode is set.
1. Cold Reset
The cold reset clears all data including preset data stored in
the RAM to initial conditions. Execute this mode when
returning the set to the customers.
Procedure:
1. Press the  ?/1  button to turn the power on.
2. Press three buttons  x  ,   A  and   ?/1  simultaneously.
3. When this button is operated, display as “COLD RESET” for
a while and all of the settings are reset.
2. Panel Test Mode
This mode is used to check the software version, FL, LED
and KEY.
2-1. Display Test Mode
Procedure:
1. Press the  ?/1  button to turn the power on.
2. Press three buttons  X ,  . and  A  simultaneously.
3. When the display test mode is activated, all segments and LEDs
are turned on.
4. To exit from this mode, press three buttons  X ,  . and  A
simultaneously.
2-2. Version Test Mode
Procedure:
1. When the display test mode is activated, press the  .  button
and the message “DSX7FW ” is displayed, the version test
mode is activated.
2. Whenever the  .  button is pressed, the display changes in
the following order.
*1: Changes depending on destination.
3. Press the  >  button and the date of the software production
is displayed.
4. Press the  >  button again and the version is displayed.
5. To exit from this mode, press three buttons  X ,  . and  A
simultaneously.
2-3. Key Test Mode
Procedure:
1. When the display test mode is activated, press the  H  button,
to select the key test mode.
2. To enter the KEY test mode, the fluorescent indicator displays
“K0 V0”. Each time a button is pressed, “KEY” value
increases. However, once a button is pressed, it is no longer
taken into account. When all keys are pressed correctly, “K8
V0” is displayed.
3. When the  VOLUME  control is turned in the direction of (+),
“V0” is changed to “V1”, then ... “V9”.
When the  VOLUME  control is turned in the direction of (–),
“V0” is changed to “V9”, then ... “V1”.
4. To exit from this mode, press three buttons  X ,  . and  A
simultaneously.
“DSX7FW” (Model name) t “XX
*1
” (Destination) t MC 
TM T DSP T TA T ST T DVD T UI T SYS  
Ver. 1.1
23
HCD-DZ810W
(2) Select “2. Drive Manual Operation” by pressing the  2 “R”
button on the remote commander. The screen will appear as
shown.
(3) Select “3. Manual Adjustment” by pressing the  3 “R”  button
on the remote commander. The screen will appear as shown.
(4) Select “6.IOP” by pressing the  6 “R”  button on the remote
commander.
(5) Wait until a hexadecimal number appear.
(6) Convert each data from hexadecimal to decimal using
  conversion table.
(7) Please find the label on the rear of the BU (Base Unit).
 The default IOP value is written in the label.
(8) Subtract between these two values.
(9) If the remainder is smaller than 93 (decimal), then it is OK.
 However if the value is higher than 93, then the BU  is defective
 and need to be change.
(10) Press the  RETURN “R”  button to return back to previous
   menu.
(11) Press the  0 “R”  button to return to Top Menu and power
   off the DVD Player.
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
5. MIRR time adjust
0. Return to top Menu
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
o
  O    Change Value
[RETURN] Return to previous menu
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop. 5B:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
Change Value
[0] Return to previous menu
DVD SECTION
8-1. GENERAL DESCRIPTION
The IOP measurement allows you to make diagnosis and adjustment
simply by using the remote commander and monitor TV. The
instructions, diagnosis results, etc. are given on the on-screen display
(OSD).
Be sure to execute the IOP measurement when a BU (Base Unit) is
replaced.
8-2. HOW TO ENTER TEST MODE
While pressing the  
x  
and  A  buttons simultaneously, turn
VOLUME +  with the DVD player in power on.
The Test Mode starts, then the menu shown below will be displayed
on the TV screen.
The menu above is the Remocon Diagnosis Menu screen which
consists of five main functions. At the bottom of the menu screen, the
model name and IF-con version. To exit from the Test Mode, press
the power button on the remote commander.
8-3. EXECUTING IOP MEASUREMENT
In order to execute IOP measurement, the following standard
procedures must be followed.
(1) In power on, while pressing the  
x  
and  A  buttons
simultaneously, turn   VOLUME +  .
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History Check
4. Version Information
Model Name
IF-con
: V
Syscon
: Ver.
er. XX.XX (XXXX)
X.XXX
: DSX7FW_ XX
*
1
*1: Changes depending on destination 
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History Check
4. Version information
Model Name
IF-con
:  Ver. XX.XX (XXXX)
Syscon
:  Ver. X.XXX
: DSX7FW_ XX
*
1
*1: Changes depending on destination 
Ver. 1.1
24
HCD-DZ810W
8-4. EMERGENCY HISTORY
To  check the emergency history, please follow the following
procedure.
(1) From the Top Menu of Remocon Diagnosis Menu, select “3.
Emergency History Check” by pressing the  3 “R”  button on
the remote commander. The following screen appears on the
on-screen display.
(2) You can check the total time when the laser is turned on during
playback of DVD and CD from the above menu. The maximum
time, which can be displayed are 999h 59min.
(3) You can check the error code of latest 10 emergency history
from the above menu. To view the previous or next page of
emergency history, press  . “R”  or  > “R” on the remote
commander. The error code consists of the following three
blocks. The first block indicates the error code. The second
block indicates the parameter and the third block indicates the
time of error code as shown below.
• Error Code
*1 : Error Code
*2 : Parameter of error code
*3 : Time of error code
Emg.History Check
1.  01  05  04  04
Laser Hours
CD
999h
59min
DVD
999h
59min
00  92  46  00
00  00  00  00
00  00  23  45
2.  02  02  01  01
00  A9  4B  00
00  00  00  00
00  00  23  45
 
Next   Next Page    Prev  Prev Page
O  Return to Top Menu
Emg.History Check
1.  01  05  04  04
Laser Hours
CD
999h
59min
DVD
999h
59min
00  92  46  00
00  00  00  00
00  00  23  45
2.  02  02  01  01
00  A9  4B  00
00  00  00  00
00  00  23  45
 
Next   Next Page    Prev  Prev Page
O  Return to Top Menu
*
1
*
2
*
3
The meaning of error code is as below:
01:
Communication error (No reply from syscon)
02:
Syscon hung up
03:
Power OFF request when syscon hung up
19:
Thermal shutdown
24:
MoveSledHome error
25:
Mechanical move error (5 Changer)
26:
Mechanical move stack error
30:
DC motor adjustment error
31:
DPD offset adjustment error
32:
TE balance adjustment error
33:
TE sensor adjustment error
34:
TE loop gain adjustment error
35:
FE loop gain adjustment error
36:
Bad jitter after adjustment
40:
Focus NG
42:
Focus layer jump NG
52:
Open kick spindle error
51:
Spindle stop error
60:
Focus on error
61:
Seek fail error
62:
Read Q data/ID error
70:
Lead in data read fail
71:
TOC read time out (CD)
80:
Can’t buffering
81:
Unknown media type
8-4-1.  Clear the Laser Hour
Press  DISPLAY “R”  button and then press  CLEAR “R”  button.
The data for both CD and DVD data are reset.
Emg.History Check
1.  01  05  04  04
Laser Hours
CD
0h
0min
DVD
0h
0min
00  92  46  00
00  00  00  00
00  00  23  45
2.  02  02  01  01
00  A9  4B  00
00  00  00  00
00  00  23  45
 
Next   Next Page    Prev  Prev Page
O  Return to Top Menu
Emg.History Check
1.  00  00  00  00
Laser Hours
CD
999h
59min
DVD
999h
59min
00  00  00  00
00  00  00  00
00  00  00  00
2.  00  00  00  00
00  00  00  00
00  00  00  00
00  00  00  00
 
Next   Next Page    Prev  Prev Page
O  Return to Top Menu
8-4-2.  Clear the Emergency History
Press  TOP MENU “R”  button and then press  CLEAR “R”  button.
The error code for all emergency history would be reset.
8-4-3.  Clear the Initialize Setup Data
Press  MENU “R”  button and then press  CLEAR “R”  button on
the remote commander.
Ver. 1.1
Page of 100
Display

Click on the first or last page to see other DAV-DZ810W / HCD-DZ810W service manuals if exist.