DOWNLOAD Sony DAV-DZ300 / HCD-DZ300 Service Manual ↓ Size: 10.65 MB | Pages: 79 in PDF or view online for FREE

Model
DAV-DZ300 HCD-DZ300
Pages
79
Size
10.65 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
dav-dz300-hcd-dz300.pdf
Date

Sony DAV-DZ300 / HCD-DZ300 Service Manual ▷ View online

17
HCD-DZ300
DVD SECTION
[TEST DISC LIST]
Be sure to use the DVD disc that matches the signal standards of
your region.
• 
CD
YEDS-18 (Part No.: 3-702-101-01)
PATD-012 (Part No.: 4-225-203-01)
• DVD SL (Single Layer)
NTSC : HLX-503 (Part No.: J-6090-069-A)
HLX-504 (Part No.: J-6090-088-A)
PAL    : HLX-506 (Part No.: J-6090-077-A)
• DVD DL (Dual Layer)
NTSC : HLX-501 (Part No.: J-6090-071-A)
HLX-505 (Part No.: J-6090-089-A)
PAL    : HLX-507 (Part No.: J-6090-078-A)
4-1. GENERAL DESCRIPTION
The Mirror Time and IOP measurement allows you to make
diagnosis and adjustment simply by using the remote commander
and monitor TV. The instructions, diagnosis results, etc. are given
on the on screen display (OSD).
The Mirror Time and IOP measurement is required is such events
where servicing a DVD-Player includes changing the Base Unit
(BU). For each new BU to be used with a certain MV-044 board,
Mirror Time and IOP measurement need to be carried out.
4-2. STARTING TEST MODE
Press three buttons  
x  
,  A and  VOLUME  + simultaneously
with the DVD player in standby mode.
The Test Mode starts, then the menu shown below will be
displayed on the TV screen.
The menu above is the Remocon Diagnosis Menu screen which
consists of six main function. At the bottom of the menu screen,
the model name and IF-con version. To enter Mirror Time
Adjustment menu, press button  2 “R”  on the remote commander
to enter Drive Manual Operation menu. To exit from the Test Mode,
press the power button on the remote commander.
4-3. DRIVE MANUAL OPERATION
The Drive Manual Operation menu consists of five main
function. By pressing  2 “R”  button on the remote commander in
the Remocon Diagnosis Menu, the screen will appear as below.
4-4. MIRROR TIME ADJUSTMENT
To enter Mirror Time Adjustment, press  5 “R”  button on the remote
commander. The screen will appear as below.
There are five main commands in the Mirr time Adjust menu as
shown in the figure above. The functions of each command are
described in the following page.
1. CD MIRR time Check
This command checks the Mirror time value for CD disc.
2. DVD MIRR time Check
This command checks the Mirror time value for DVD disc.
3. Threshold
This command displays the threshold value between CD and DVD
mirror time.
4. Save to EEPROM
This command saves an adjusted mirror time value to the EEPROM.
5. Default set MIRR time
This command will set CD and DVD mirror time to firmware default
value.
[Open] / [Close]
Pressing the  A  button controls the tray for disc change
during mirror time adjustment.
[0] Return to previous menu
Press  0 “R”  button to return to previous menu.
4-4-1. EXECUTING MIRROR TIME ADJUSTMENT
In order to execute mirror time adjustment, the following standard
procedures must be followed.
(1) In standby mode, press three buttons  x  ,  A  and  VOLUME
+ simultaneously.
(2) Select “2. Drive Manual Operation”.
MIRR time Adjust Menu
1. CD MIRR time Check:
2. DVD MIRR time Check:
3. Threshold:
4. Save to EEPROM
5. Default set MIRR time
[Open] Tray open [Close] Tray close
[0] Return to previous menu
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History Check
4. Version information
5. Video Level Adjustment
Model
:  DS3_xx
IF-con
: Ver. xx.xx (xxxx)
Syscon
: Ver. x.xxx
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
5. Video Level Adjustment
Model Name : DS3_XX
IF-con
: V
Syscon
: Ver.
er. xx.xx (xxxx)
x.xxx
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
5. MIRR time Adjust
0. Return to Top Menu
Ver. 1.1
18
HCD-DZ300
(3) Select “5. MIRR time Adjust”.
(4) Select “5. Default set MIRR time”.
(5) Select “3. Threshold”.
(6) Confirm the number. If it is 7D, go to next step. If it is any
      other value, return to step 4.
(7) Push  A  button to eject tray.
(8) Insert Test Disc HLX-504 into tray.
(9) Push  A  button to close tray.
(10) Push “2. DVD MIRR time Check”.
(11) Wait for HEX number to display.
(12) Confirm the number, if XX is 28 ~ 70, proceed with next
        step. If no, return to 8.
(13) Push “4. Save to EEPROM”.
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Mecha test mode
5. MIRR time Adjust
0. Return to Top Menu
MIRR time Adjust Menu
1. CD MIRR time Check:
2. DVD MIRR time Check:
3. Threshold:
4. Save to EEPROM:
5. Default set MIRR time:
[Open] Tray open [Close] Tray close
[0] Return to previous menu
MIRR time Adjust Menu
1. CD MIRR time Check:
2. DVD MIRR time Check:
3. Threshold: 7D
4. Save to EEPROM:
5. Default set MIRR time:
[Open] Tray open [Close] Tray close
[0] Return to previous menu
MIRR time Adjust Menu
1. CD MIRR time Check:
2. DVD MIRR time Check:  xx  xx
3. Thereshold:
4. Save to EEPROM:
5. Default set MIRR time:
[Open] tray open [close] Tray close
[0] Return to previous menu
(14) Confirm the same values are displayed. If it is not same,
        return to step 7.
(15) Push  A  button to eject tray.
(16) Take out HLX-504 and insert Test Disc YEDS-18 into
        tray.
(17) Push  A  button to close tray.
(18) Push “1. CD MIRR time check”.
(19) Wait for HEX number to display.
(20) Confirm the number, if YY is 5A ~ E8, proceed with next
        step. If no, return to 15.
(21) Push “4. Save to EEPROM”.
(22) Confirm the same values are displayed. If it is not the
        same, return to step 15.
(23) Push  A  button to eject tray.
(24) Remove Test Disc YEDS-18 from tray.
(25) Push  A  button to close tray.
(26) Press  0 “R”  button to the Drive Manual Operation menu.
(27) Press  0 “R”  button to return to the Remocon Diagnosis
Menu.
(28) Press the  ?/1  button to switch OFF set.
MIRR time Adjust Menu
1. CD MIRR time Check:
2. DVD MIRR time Check:  XX XX
3. Threshold:
4. Save to EEPROM:
5. Default set MIRR time:
[Open] Tray open [close] Tray close
[0] Return to previous menu
MIRR time Adjust Menu
1. CD MIRR time Check:  yy  YY
2. DVD MIRR time Check:  XX  XX
3. Threshold:
4. Save to EEPROM:
5. Default set MIRR time:
[Open] Tray open [close] Tray close
[0] Return to previous menu
MIRR time Adjust Menu
1. CD MIRR time check:  YY  YY
2. DVD MIRR time check:  XX  XX
3. Threshold:
4. Save to EEPROM:
5. Default set MIRR time:
[Open] Tray open [close] Tray close
[0] Return to previous menu
19
HCD-DZ300
4-5. EXECUTING IOP MEASUREMENT
In order to execute mirror time adjustment, the following standard
procedures must be followed.
(1) In standby mode, press three buttons  x  ,  A  and  VOLUME
+ simultaneously.
(2) Select “2. Drive Manual Operation” by pressing the  2 “R”
button on the remote commander. The screen will appear as
     below.
(3) Select “3. Manual Adjustment” by pressing the  3 “R”  button
on the remote commander. The screen will appear as below.
(4) Select Iop by pressing  6 “R”  button on the remote commander.
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History Check
4. Version information
5. Video Level Adjustment
Model
: DS3 XX
IF-con  Ver
: XX.XX (XXXX)
Syscon  Ver : X.XX
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
5. MIRR time adjust
0. Return to top Menu
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
o
  O    Change Value
[RETURN] Return to previous menu
(5) Wait until a hexadecimal number appear.
(6) Convert each data from hexadecimal to decimal using
      conversion table.
(7) Substract between these two values.
(8) If the remainder is smaller than 93 (decimal), then it is
      OK. However if the value is higher than 93, then the BU
      is defective and need to be change.
(9) Press  RETURN “R”  button to return back to previous menu.
(10) Press  0 “R”  button to return to Top Menu and power OFF
the DVD Player.
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop. 5B:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
Change Value
[0] Return to previous menu
20
HCD-DZ300
SECTION  5
ELECTRICAL ADJSTMENT
Checking Location: DMB10 board (Side A)
IC102
IC101
IC104
IC201
CN105
CN106
CN105 pin 
3
 (GND)
CN105 pin 
6
 (RFMON)
1
6
DVD SECTION
When the base unit is replaced, perform the adjustment and the
measurement as shown below in this order.
1) MIRROR TIME ADJUSTMENT (See page 17)
2) EXECUTING IOP MEASUREMENT (See page 19)
[TEST DISC LIST]
Be sure to use the DVD disc that matches the signal standards of
your region.
• 
CD
YEDS-18 (Part No.: 3-702-101-01)
PATD-012 (Part No.: 4-225-203-01)
• DVD SL (Single Layer)
NTSC : HLX-503 (Part No.: J-6090-069-A)
HLX-504 (Part No.: J-6090-088-A)
PAL    : HLX-506 (Part No.: J-6090-077-A)
• DVD DL (Dual Layer)
NTSC : HLX-501 (Part No.: J-6090-071-A)
HLX-505 (Part No.: J-6090-089-A)
PAL    : HLX-507 (Part No.: J-6090-078-A)
[RF Level Check]
Connection:
Procedure:
1. Conect an oscilloscope to CN105 pin 6 (RFMON) and CN105
pin 3 (GND) on the DMB10 board.
2. Turn the power on.
3. Insert the CD test disc (refer to the TEST DISC LIST), and
press the  H  button to play the disc back.
4. Confirm that oscilloscope waveform is clear and check RF
signal level is correct or not.
Note: 
A clear RF signal waveform means that the shape “
” can be
clearly distinguished at the center of the waveform.
5. Eject the CD disc, and insert the DVD SL test disk (refer to the
TEST DISC LIST), and press the  H button to play the disc
back.
+
CN105 pin 
6
 (RFMON)
CN105 pin 
3
 (GND)
oscilloscope 
DMB10 board
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
RF signal waveform
level: 0.57 
±
 1.1 Vp-p (CD)
          0.58 
±
 1.23 Vp-p (DVD)
Ver. 1.1
Page of 79
Display

Click on the first or last page to see other DAV-DZ300 / HCD-DZ300 service manuals if exist.