Sony DAV-DZ266K / DAV-DZ270K / DAV-DZ570K / DAV-DZ777K / HCD-DZ265K / HCD-DZ266K / HCD-DZ270K / HCD-DZ570K / HCD-DZ777K Service Manual ▷ View online
HCD-DZ265K/DZ266K/DZ270K/DZ570K/DZ777K
25
SECTION 4
TEST MODE
Note:
Incorrect operations may be performed if the test mode is not
entered properly.
entered properly.
In this case, press the [
?/1
] button to turn the power off, and
retry to enter the test mode.
1. Cold Reset
• The cold reset clears all data including preset data stored in the
• The cold reset clears all data including preset data stored in the
RAM to initial conditions. Execute this mode when returning
the set to the customers.
the set to the customers.
Procedure:
1. Press the [
1. Press the [
?/1
] button to turn the power on.
2. Press three buttons [
x
], [
A
] and [
?/1
] simultaneously.
3. When this button is operated, display as “COLD RESET” for
a while and all of the settings are reset.
2. Panel Test Mode
• This mode is used to check the software version, FL and
• This mode is used to check the software version, FL and
KEY.
2-1. Display Test Mode
Procedure:
1. Press the [
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. Press three buttons [
X
], [
.
] and [
A
] simultaneously.
3. When the display test mode is activated, all segments are turned
on.
4. To exit from this mode, press three buttons [
X
], [
.
] and [
A
]
simultaneously.
2-2. Version Test Mode
Procedure:
1. When the display test mode is activated, press the [
Procedure:
1. When the display test mode is activated, press the [
.
] button
and the message “DSR2K–” (DZ265K), “DSR2K+” (DZ266K),
“DSR2K” (DZ270K), “DSR4K” (DZ570K), “DSR7K” (DZ777K)
are displayed, the version test mode is activated.
“DSR2K” (DZ270K), “DSR4K” (DZ570K), “DSR7K” (DZ777K)
are displayed, the version test mode is activated.
2. Whenever the [
.
] button is pressed, the display changes in
the following order.
“DSR7K” (Model name) U“ASIA2
*1
” (Destination) U
UMC Version U SYS Version UUI Version U
UDVD Version UST Version U TA Version U
UDSP Version UTM Version UMM Version U
UDVD Version UST Version U TA Version U
UDSP Version UTM Version UMM Version U
U CLA Version UCEC Version USAIR Version
*1: ASIA2 changes depending on destination.
3. Press the [
>
] button and the date of the software production
is displayed.
4. Press the [
>
] button again and the version is displayed.
5. To exit from this mode, press three buttons [
X
], [
.
] and [
A
]
simultaneously.
2-3. Key Test Mode
Procedure:
1. When the display test mode is activated, press the [
Procedure:
1. When the display test mode is activated, press the [
H
] button,
to select the key test mode.
2. To enter the KEY test mode, the fl uorescent indicator displays
“K0 V0”. Each time an another button is pressed, “KEY” value
increases. However, once a button is pressed, it is no longer
taken into account. When all keys are pressed correctly, “K8
V0” is displayed.
increases. However, once a button is pressed, it is no longer
taken into account. When all keys are pressed correctly, “K8
V0” is displayed.
3. When the [VOLUME] control is turned in the direction of (+),
“V0” is changed to “V1”, then ... “V9”.
When the [VOLUME] control is turned in the direction of (–),
“V0” is changed to “V9”, then ... “V1”.
“V0” is changed to “V9”, then ... “V1”.
4. To exit from this mode, press three buttons [
X
], [
.
] and [
A
]
simultaneously.
3. Disc Tray Lock
The disc tray lock function for the antitheft of an demonstration
disc in the store is equipped.
Setting Procedure :
1. Press the [
The disc tray lock function for the antitheft of an demonstration
disc in the store is equipped.
Setting Procedure :
1. Press the [
?/1
] button to turn the set on.
2. Press the [FUNCTION] button to set DVD function.
3. Insert a disc.
4. Press
3. Insert a disc.
4. Press
the
[
x
] button and the [
A
] button simultaneously for fi ve
seconds.
5. The message “LOCKED” is displayed and the tray is locked.
Releasing Procedure :
1. Press
Releasing Procedure :
1. Press
the
[
x
] button and the [
A
] button simultaneously for fi ve
seconds again.
2. The message “UNLOCKED” is displayed and the tray is
unlocked.
Note: When “LOCKED” is displayed, the tray lock is not released by
turning power on/off with the [
?/1
] button.
4. DVD Ship Mode
Use this mode when returning the set to the customer after repair.
Procedure:
1. Press the [
Use this mode when returning the set to the customer after repair.
Procedure:
1. Press the [
?/1
] button to turn the set on.
2. Press the [FUNCTION] button to set the function “DVD”.
3. Remove all Discs, and then press two buttons [
3. Remove all Discs, and then press two buttons [
H
] and [
?/1
]
simultaneously.
4. After a message “MECHA LOCK” h “PULL PLUG” is
displayed on the fl uorescent indicator tube, pull out the AC
plug.
plug.
5. To exit from this mode, press the [
?/1
] button to turn the set
on.
5. AM Step Change (Except RU models)
• A step of AM channels can be changed over between 9 kHz
• A step of AM channels can be changed over between 9 kHz
and 10 kHz.
Procedure:
1. Press the [
1. Press the [
?/1
] button to turn the set ON.
2. Select the function “TUNER”, and press [FUNCTION] button
to select the BAND “AM”.
3. Press the [
?/1
] button to turn the set OFF.
4. Press two buttons [
>
] and [
?/1
] simultaneously, and the
display of fl uorescent indicator tube changes to “AM 9k STEP”
or “AM 10k STEP”, and thus the channel step is changed
over.
or “AM 10k STEP”, and thus the channel step is changed
over.
6. Product Out
This mode moves the optical pick-up to the position durable to
vibration and clears all data including preset data stored in the
RAM to initial conditions. Use this mode when returning the set to
the customer after repair.
Procedure:
1. Press the [
This mode moves the optical pick-up to the position durable to
vibration and clears all data including preset data stored in the
RAM to initial conditions. Use this mode when returning the set to
the customer after repair.
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. Press the [FUNCTION] button to set the function “DVD”.
3. Remove all discs, and then press three buttons [
3. Remove all discs, and then press three buttons [
>
], [
A
] and
[
?/1
] simultaneously.
4. After the “STANDBY” blinking display fi nishes, the message
“MECHA LOCK” h “PULL PLUG” is displayed on the
fl uorescent indicator tube disconnect the AC power plug, then
the ship mode is set.
fl uorescent indicator tube disconnect the AC power plug, then
the ship mode is set.
HCD-DZ265K/DZ266K/DZ270K/DZ570K/DZ777K
26
7-1. GENERAL DESCRIPTION
The IOP measurement allows you to make diagnosis and
adjustment simply by using the remote commander and monitor
TV. The instructions, diagnosis results, etc. are given on the on-
screen display (OSD).
Be sure to execute the IOP measurement when a BU (Base Unit)
is replaced.
The IOP measurement allows you to make diagnosis and
adjustment simply by using the remote commander and monitor
TV. The instructions, diagnosis results, etc. are given on the on-
screen display (OSD).
Be sure to execute the IOP measurement when a BU (Base Unit)
is replaced.
7-2. HOW TO ENTER TEST MODE
While pressing the [
While pressing the [
x
] and [
A
] buttons simultaneously, turn
[VOLUME] control in the direction of (+) with the DVD player
in power on.
The Test Mode starts, displayed “SERVICE IN” on this model
display then the menu shown below will be displayed on the TV
screen.
* The display of the “Model Name” of the “Remocon Diagnosis
in power on.
The Test Mode starts, displayed “SERVICE IN” on this model
display then the menu shown below will be displayed on the TV
screen.
* The display of the “Model Name” of the “Remocon Diagnosis
Menu” change with the model and the destination. Refer to
below on the model name.
below on the model name.
DZ265K
:
DSR2K–
DZ266K
:
DSR2K+
DZ270K
:
DSR2K
DZ570K
:
DSR4K
DZ777K
:
DSR7K
The menu above is the Remocon Diagnosis Menu screen which
consists of fi ve main functions. At the bottom of the menu screen,
the model name and IF-con version. To exit from the Test Mode,
press the power button on the remote commander.
consists of fi ve main functions. At the bottom of the menu screen,
the model name and IF-con version. To exit from the Test Mode,
press the power button on the remote commander.
7-3. EXECUTING IOP MEASUREMENT
In order to execute IOP measurement, the following standard
procedures must be followed.
In order to execute IOP measurement, the following standard
procedures must be followed.
(1) In power on, while pressing the [
x
] and [
A
] buttons
simultaneously, turn the [VOLUME] control in the direction
of (+).
of (+).
(2) Select “2. Drive Manual Operation” by pressing the [2] button
on the remote commander. The screen will appear as shown.
(3) Select “3. Manual Adjustment” by pressing the [3] button on
the remote commander. The screen will appear as shown.
(4) Select “6. IOP” by pressing the [6] button on the remote
commander.
(5) Wait until a hexadecimal number appear.
(6) Convert each data from hexadecimal to decimal using
conversion table.
(7) Please fi nd the label on the rear of the BU (Base Unit).
The default IOP value is written in the label.
(8) Subtract between these two values.
(9) If the remainder is smaller than 93 (decimal), then it is OK.
However if the value is higher than 93, then the BU is defective
and need to be change.
and need to be change.
(10) Press the [RETURN] button on the remote commander to
return back to previous menu.
(11) Press the [0] button on the remote commander to return to Top
Menu.
DVD SECTION
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
Model Name
IF-con
IF-con
: Ver. XX.XX (XXXX)
Syscon
: Ver. X.XXX
: DSR7K_XX
*
1
*1: Changes depending on destination
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
Model Name
IF-con
IF-con
: Ver. XX.XX (XXXX)
Syscon
: Ver. X.XXX
: DSR7K_XX
*
1
*1: Changes depending on destination
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
5. MIRR time adjust
0. Return to Top Menu
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
5. MIRR time adjust
0. Return to Top Menu
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
0 P Change Value
[RETURN] Return to previous menu
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop. 4D:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop. 4D:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
[RETURN] Return to previous menu
0 P Change Value
HCD-DZ265K/DZ266K/DZ270K/DZ570K/DZ777K
27
7-4. EMERGENCY HISTORY
To check the emergency history, please follow the following
procedure.
To check the emergency history, please follow the following
procedure.
(1) From the Top Menu of Remocon Diagnosis Menu, select “3.
Emergency History Check” by pressing the [3] button on the
remote commander. The following screen appears on the on-
screen display.
remote commander. The following screen appears on the on-
screen display.
(2) You can check the total time when the laser is turned on during
playback of DVD and CD from the above menu. The maximum
time, which can be displayed are 999h 59min.
time, which can be displayed are 999h 59min.
(3) You can check the error code of latest 10 emergency history
from the above menu. To view the previous or next page of
emergency history, press [
emergency history, press [
.
] or [
>
] button on the remote
commander. The error code consists of the following three
blocks. The fi rst block indicates the error code. The second
block indicates the parameter and the third block indicates the
time of error code as shown below.
blocks. The fi rst block indicates the error code. The second
block indicates the parameter and the third block indicates the
time of error code as shown below.
• Error Code
*1 : Error Code
*2 : Parameter of error code
*3 : Time of error code
The meaning of error code is as below:
01: Communication error (No reply from syscon)
02: Syscon hung up
03: Power OFF request when syscon hung up
19: Thermal shutdown
24: MoveSledHome error
25: Mechanical move error (5 Changer)
26: Mechanical move stack error
30: DC motor adjustment error
31: DPD offset adjustment error
32: TE balance adjustment error
33: TE sensor adjustment error
34: TE loop gain adjustment error
35: FE loop gain adjustment error
36: Bad jitter after adjustment
40: Focus NG
42: Focus layer jump NG
52: Open kick spindle error
51: Spindle stop error
60: Focus on error
61: Seek fail error
62: Read Q data/ID error
70: Lead in data read fail
71: TOC read time out (CD)
80: Can’t buffering
81: Unknown media type
7-4-1. Clear the Laser Hour
Press [ DISPLAY] button and then press [CLEAR] button on
the remote commander. The data for both CD and DVD data are
reset.
Press [ DISPLAY] button and then press [CLEAR] button on
the remote commander. The data for both CD and DVD data are
reset.
7-4-2. Clear the Emergency History
Press [DVD TOP MENU] button and then press [CLEAR] button
on the remote commander. The error code for all emergency history
would be reset.
Press [DVD TOP MENU] button and then press [CLEAR] button
on the remote commander. The error code for all emergency history
would be reset.
7-4-3. Clear the Initialize Setup Data
Press [DVD MENU] button and then press [CLEAR] button on the
remote commander.
Press [DVD MENU] button and then press [CLEAR] button on the
remote commander.
Emg. History Check
01. 01 05 04 04
Laser Hours
CD
999h
59min
DVD
999h
59min
00 92 46 00
00 00 00 00
00 00 23 45
02. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
[Next] Next Page [Prev] Prev Page
[O] Return to Top Menu
[O] Return to Top Menu
Emg. History Check
01. 01 05 04 04
Laser Hours
CD
999h
59min
DVD
999h
59min
00 92 46 00
00 00 00 00
00 00 23 45
02. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
[Next] Next Page [Prev] Prev Page
[O] Return to Top Menu
[O] Return to Top Menu
*
1
*
2
*
3
Emg. History Check
01. 01 05 04 04
Laser Hours
CD
0h
0min
DVD
0h
0min
00 92 46 00
00 00 00 00
00 00 23 45
02. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
[Next] Next Page [Prev] Prev Page
[O] Return to Top Menu
[O] Return to Top Menu
01. 00 00 00 00
Laser Hours
CD
999h
59min
DVD
999h
59min
00 00 00 00
00 00 00 00
00 00 00 00
02. 00 00 00 00
00 00 00 00
00 00 00 00
00 00 00 00
[Next] Next Page [Prev] Prev Page
[O] Return to Top Menu
[O] Return to Top Menu
Emg. History Check
Emg. History Check
initialize setup data...
Laser Hours
CD
999h
59min
DVD
999h
59min
[Next] Next Page [Prev] Prev Page
[O] Return to Top Menu
[O] Return to Top Menu
HCD-DZ265K/DZ266K/DZ270K/DZ570K/DZ777K
28
8. DEMO PLAY OUT
It is a mode to release the demonstration reproduct by the dedicated
demonstration disc.
1. During playback the DEMO Disc, press the [
It is a mode to release the demonstration reproduct by the dedicated
demonstration disc.
1. During playback the DEMO Disc, press the [
x
] and [
H
]
buttons for fi ve seconds simultaneously.
2. The message “DEMO OFF” is displayed, a mode to reproduct
the demonstration is released.
9. DIGITAL MEDIA PORT TEST
1. Connect the DMPORT CHECK JIG (P/N: J-2501-309-A) with
1. Connect the DMPORT CHECK JIG (P/N: J-2501-309-A) with
the terminal DMPORT.
2. Press the [
?/1
] button to turn the power on.
3. Confi rm that both LEDs of the DMPORT confi rmation JIG
lights. (Confi rmation the power supply line.)
4. Set the [FUNCTION] button with “DMPORT” on this model.
5. Press the [
5. Press the [
X
], [
.
] buttons and turn the [VOLUME] control
in the direction of (+) simultaneously, the DMPORT test mode
is activated.
is activated.
6. It is confi rmed that “DMPORT OK” is displayed on this set
display. (Confi rmation of communication line)
7. To a pin jack of the DMPORT confi rmation JIG input
information relevant to audio signal (sine-wave 1.0Vrms) and
composite video signal (white 100% 1.0Vp-p, color bar, etc.)
composite video signal (white 100% 1.0Vp-p, color bar, etc.)
8. Confi rm the output of speakers and monitor TV. (Confi rmation
of analog signal)
9. To exit from this mode, press the [
X
], [
.
] buttons and turn
the [VOLUME] control in the direction of (+).
7-4-4. Return to the Top Menu of Remocon Diagnosis
Menu
Press [0] button on the remote commander.
• Check Version Information
To check the version information, please follow the following
procedure.
To check the version information, please follow the following
procedure.
(1) From the Top Menu of Remocon Diagnosis Menu, select “4.
Version Information” by pressing the [4] button on the remote
commander. The following screen appears on the on-screen
display.
commander. The following screen appears on the on-screen
display.
To return to the Top Menu of Remocon Diagnosis Menu, press
[0] button on the remote commander.
[0] button on the remote commander.
7-5. AUTOMATIC ACOUSTIC FIELD CALIBRATION
MICROPHONE TEST MODE
Procedure:
1. Press the [
1. Press the [
?/1
] button to turn the power on.
2. Press the [FUNCTION] button to set the function “ DVD”.
3. Insert ECM-AC2 supplied as an accessory into the AUDIO IN/
3. Insert ECM-AC2 supplied as an accessory into the AUDIO IN/
A.CAL MIC jack.
4. While pressing the [
X
] and [
A
] buttons simultaneously, turn
the [VOLUME] control in the direction of (+).
5. Confi rm that the following are shown on the display panel.
1
The JACK inserted/non-inserted detection display and the
STEREO/MONO detection display.
2
Presence of DIGITAL voice input to the microcomputer.
(OK: input, NG: no input)
3
The value of the MIC input to the microcomputer. (shown
“255h”)
6. To exit from this mode, press the [
X
] and [
A
] buttons simulta-
neously, turn the [VOLUME] control in the direction of (+).
Version information
[O] Return to Top Menu
Firm (Main) : Ver. xxxxx
Firm (Sub) : xxxxx
RISC : xxxxx
8032 : xxxxx
Audio DSP : xxxxx
Servo DSP : xxxxx
Firm (Sub) : xxxxx
RISC : xxxxx
8032 : xxxxx
Audio DSP : xxxxx
Servo DSP : xxxxx
“NON” : Not detected
“ST” :
STEREO
“MN” :
MONO
OK : input
NG : no input
0-255 (Changes in real time)
color pattern
generator
DMPORT
CHECK JIG
(P/N: J-2501-309-A)
MAIN
board
TV
CN204
J404
J001 7
AF oscillator
FL speaker,
FR speaker
IO-COMPONENT
board
SPEAKER
board
TB100
VIDEO
AUDIO
SET
Click on the first or last page to see other DAV-DZ266K / DAV-DZ270K / DAV-DZ570K / DAV-DZ777K / HCD-DZ265K / HCD-DZ266K / HCD-DZ270K / HCD-DZ570K / HCD-DZ777K service manuals if exist.