CX-LEMV300
[TC Test  Mode]
Procedure:
1. Extract an AC plug.
2. While depressing the  TAPE N  button, insert an AC plug.
3. The message “TC TEST” is displayed and TC test mode is
activated.
*
Zero Return
1. Press the  M >  or  .m  button.
2. The tape is rewound to the counter zero position.
*
Automatic record/playback test
1. Press  the  REC START/REC PAUSE  button.
2. The message “AUX” is displayed and AUX input is selected.
3. The tape is rewound to the counter zero position and recording
is started automatically.
4. When the  CLEAR x  button  is pressed, the tape is rewound
to the recording stated point and the set starts playback.
5. To exit from this mode, press the  POWER  button or disconnect
the power cord.
SECTION  4
MECHANICAL ADJUSTMENTS
  TAPE MECHANISM DECK SECTION
Precaution
1. Clean the following parts with a denatured alcohol-moistened
swab:
record/playback heads
pinch rollers
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head demagne-
tizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
Torque Measurement
2.94 mN • m to 7.84 mN • m
31 to 71 g • cm
(0.43 – 0.98 oz • inch)
0.14 mN • m to 0.59 mN • m
2 to 6 g • cm
(0.02 – 0.08 oz • inch)
6.86 mN • m to 17.64 mN • m
71 to 143 g • cm
(0.98 – 1.99 oz • inch)
more than 0.98 N • m
100 g or more
(3.53 oz or more)
Mode
Torque meter
CQ-102C
CQ-102C
CQ-201B
CQ-403A
Meter reading
FWD
FWD
back tension
FF/REW
FWD tension
14
CX-LEMV300
SECTION  5
ELECTRICAL  ADJUSTMENTS
Precaution
1. Demagnetize the record/playback head with a head demagne-
tizer.
2. Do not use a magnetized screwdriver for the adjustments.
3. After the adjustments, apply suitable locking compound to the
parts adjust.
4. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
5. The adjustments should be performed in the order given in
this service manual.  (As a general rule, playback circuit ad-
justment should be completed before performing recording
circuit adjustment.)
6. The adjustments should be performed for both L-CH and R-
CH.
7. Switches and controls should be set as follows unless other-
wise specified.
• Test Tape
Tape
Signal
Used for
P-4-A100
10 kHz, – 10 dB
Azimuth Adjustment
WS-48B
3 kHz, 0 dB
Tape Speed Check
0 dB = 0.775 V
DECK  SECTION
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
3. Mode: Playback
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
Screw
position
L-CH
peak
within
1dB
Output
level
L-CH
peak
R-CH
peak
within
1dB
Screw
position
R-CH
peak
set
test tape
P-4-A100
(10 kHz, – 10 dB)
R-CH
oscilloscope
L-CH
R-CH
V
H
waveform of oscilloscope
in phase 45
°
90
°
135
°
180
°
good
wrong
MAIN board
SPEAKER terminal (J302)
L-CH
Record/Playback Head Azimuth Adjustment
Procedure:
1. Mode: Playback
set
MAIN board
SPEAKER terminal (J302)
L-CH, R-CH
+
level meter
test tape
P-4-A100
(10 kHz, – 10 dB)
15
CX-LEMV300
Tape Speed Check
Mode: Playback
1. Insert the WS-48B into the deck.
2. Press the N button on the deck.
3. Confirm that the frequency counter reads 3,000 
±
 90 Hz.
Sample value of Wow and Flutter: 0.3% or less W.RMS (JIS)
(WS-48B)
+
set
test tape
WS-48B 
(3 kHz, 0 dB)
MAIN board
SPEAKER terminal (J302)
L-CH, R-CH
frequency counter
Adjustment Location: Record/Playback/Erase Head
Note: Refer to “3-6. Cassette Door Assy” (see page 10)
adjustment screw
CD  SECTION
Note:
1. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
2. Use an oscilloscope with more than 10M
 impedance.
3. Clean the object lens by an applicator with neutral detergent when the
signal level is low than specified value with the following checks.
RFDC Level Check
Connection:
Procedure:
1.
Connect an oscilloscope to test point TP6 (RFDC) and TP7 (VC)
on the BD board.
2.
Turn the power on.
3.
Put the disc (YEDS-18) in to playback the number five track.
4.
Confirm that oscilloscope waveform is clear and check RFDC
signal level is correct or not.
Note:
A clear RFDC signal waveform means that the shape “
” can be
clearly distinguished at the center of the waveform.
+
BD board
TP6 (RFDC)
TP7 (VC)
oscilloscope
S-curve Check
Connection:
Procedure:
1.
Connect an oscilloscope to test point TP4 (FE) and TP7 (VC)
on the BD board.
2.
While depressing the  CD         button, insert an AC plug.
3.
Put the disc (YEDS-18) in and press the       button and
actuate the focus search. (actuate the focus search when disc
table is moving in and out)
4.
Check the oscilloscope waveform (S-curve) is symmetrical
between A and B. And confirm peak to peak level within 2 
±
 1
Vp-p.
S-curve waveform
Note:
• Try to measure several times to make sure than the ratio of A : B
or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
Checking Location: BD board (Side B)(See page 25)
+
BD board
TP4 (FE)
TP7 (VC)
oscilloscope
A
B
symmetry
within 2 
±
 1 Vp-p
u
x
16
CX-LEMV300
Checking Location: BD board (Side B)
Traverse Waveform
0V
B
level: 1.0 
±
 0.5 Vp-p
Center of 
the waveform
A (DC 
voltage)
Traverse Waveform
0V
Tracking servo
Sled servo
ON
C (DC 
voltage)
Tracking servo
Sled servo
OFF
6.
Press the CD 
u
   button. (The tracking servo and sledding
servo are turned ON)
Rotate RV101 on BD board and adjust the C (DC voltage) 
is almost equal to the A (DC voltage) in step 4. 
7. To exit from this mode, turn the power off.
Notes:
• Always move the optical pick-up to most inside track when
exiting from this mode. Otherwise, a disc will not be unloaded.
• Do not run the sled motor excessively, otherwise the gear can
be chipped.
5.
Check the level B of the oscilliscope's waveform and the A
(DC voltage) of the center of the Traverse waveform.
Confirm the following :
A/B x 100 = less than 
±
 10%
Checking Location:
– BD BOARD (Side B) –
       RFDC signal waveform
Checking Location: BD board (Side B)(See page 25)
VOLT/DIV: 200 mV
TIME/DIV: 500 ns 
level: 0.6 
±
 0.15 Vp-p
RFAC Level Check
Connection:
Procedure:
1.
Connect an oscilloscope to test point TP8 (RFAC) and TP7
(VC) on the BD board.
2.
Turn the power on.
3.
Put the disc (YEDS-18) in to playback the number five track.
4.
Confirm that oscilloscope waveform is clear and check RFAC
signal level is correct or not.
Note:
A clear RFAC signal waveform means that the shape “
” can be
clearly distinguished at the center of the waveform.
       RFAC signal waveform
Checking Location: BD board (Side B)(See page 25)
+
BD board
TP8 (RFAC)
TP7 (VC)
oscilloscope
VOLT/DIV: 200 mV
TIME/DIV: 500 ns 
level: 1.0 
±
 0.4 Vp-p
+
BD board
TP2 (TE)
TP7 (VC)
oscilloscope
E-F Balance Adjustment
Connection:
Procedure:
1.
Connect an oscilloscpe to test point TP2 (TE) and  TP7 (VC)
on the BD board.
2.
AC is put in pushing CD 
u
button to enter the CD test 
mode.
3.
Put the disc (YEDS-18) in to playback the number five track.
4.
Press the                      button. If it plays, press the
CD 
u
  
button again. (The tracking servo and the sledding servo are
turned OFF)
CD 
u
  
IC101
TP7
(VC)
IC103
RV101
E-F Balance
Adjustment
  TP8
(RFAC)
  TP6
(RFDC)
TP4
(FE)
TP2
(TE)