3-16. TABLE  ASSY
3
wire (flat type) (5 core)
(CN702)
4
hook
1
Turn the loading gear
in the direction of arrow 
A
.
A
5
two claws
2
Pull-out the table assy.
6
table assy
3-17. MOTOR (TB)  BOARD
2
tray
4
connector
(CN731)
1
screw
(PTPWH M2.6)
5
two screws
(BTTP M2.6)
6
motor (TB) board
3
belt (table)
Ver. 1.2
CX-JD5
18
3-18. MOTOR (LD)  BOARD
3-19. RF  BOARD
2
two screws
(BTTP M2.6)
3
motor (LD) board
1
belt (loading)
3
flexible flat cable
(24 core) (CN001)
4
flexible board
(CN003)
1
two screws
(BTTP 2.6)
2
RF board
CX-JD5
19
3-20. OPTICAL  TRAVERSE  UNIT (DBU-1)
7
 insulator
2
8
 insulator (HRC)
6
 insulator
(HRC)
0
holder (DBU) assy
4
 step screw (M)
5
 step screw (M)
1
 floating screw (PTPWH M2.6)
3
 step screw (M)
9
 optical traverse unit (DBU-1)
20
CX-JD5
SECTION  4
TEST  MODE
[MC  TEST  MODE]
• This mode is used to check operations of the respective sections
of Amplifier, Tuner, and Tape.
Procedure:
*   To enter MC Test Mode
1. Press
x
button, 
[ENTER]
  button and 
[DISC 3]
  button
simultaneously, the message “TEST MODE” will be displayed
on the fluorescent indicator tube.
*   Check of Amplifier
1. When 
[BASS]
 knob is turned clockwise, GEQ increases to its
maximum and a message “GEQ MAX” appears on the
fluorescent indicator tube.
2. When 
[BASS]
  knob is turned counter clockwise, GEQ
decreases to its minimum and a message “GEQ MIN” appears
on the fluorescent indicator tube.
3. When 
[SOUND FIELD]
 button is pressed, GEQ is set to flat
and a message “GEQ FLAT” appears on the fluorescent
indicator tube.
4. When the 
[VOLUME]
 knob is turned clockwise even slightly,
the sound volume increases to its maximum and a message
“VOL MAX” appears for two seconds, then the display returns
to the original display.
5. When the 
[VOLUME]
 knob is turned counter-clockwise even
slightly, the sound volume decreases to its minimum and a
message “VOL 0” appears for two seconds, then the display
returns to the original display.
*   VACS ON/OFF Change Over
1. Press 
[i-Bass]
 button. The message “VACS OFF” or “VACS
ON” appears.
*   Tape function
1. When a tape is inserted in Deck B and recording is started, the
function is changed to VIDEO automatically.
2. After recording is stopped by pressing
x
button, press
– 
m
button will change the function to TAPE B and rewind Tape B
until the recording start position and playback of Tape B is
started. If the 
[REC PAUSE/ START]
  button is pressed for a
pause and pressed again to resume recording during recording
time, when tape deck B is rewind, tape deck B will be rewind
until the position where the pause is applied.
*   AMS Test Mode
1. Select the function “TAPE A” or “TAPE B”.
2. Insert a test tape AMS-110A or AMS-120 to selected tape deck.
3. Press the 
[CD STNC]
 button to enter the AMS test mode.
4. After the test tape is rewind to the beginning of the tape, the
AMS+ is checked, and the mechanism is shut off after detecting
the AMS signal twice.
5. Then the AMS- is checked and the mechanism is shut off after
detecting the AMS signal twice.
6. When the check is complete, a message of either OK or NG
appears.
*   To release MC Test mode.
1. To release this mode, press 
[POWER]
 button.
2. The cold reset is enforced at the same time.
[AMP TEST MODE ]
• This mode is used in order to set up each section of amplifier.
Procedure:
1. Press
x
button, 
[ENTER]
  button and 
[DISC2]
  button
simultaneously, the message “AMP TEST” will be displayed
on the fluorescent indicator tube.
2. Press 
[ENTER]
  button and 
[DISC1]
  button simultaneously,
VACS  display/amplifier regulation display is switched.
3. Press 
[SOUND FIELD]
  button, SURROUND ON/OFF is
switched.
4. Press 
[i-Bass]
 button, i-Bass ON/OFF is switched.
5. Turn the 
[BASS]
 knob, BASS (i-Bass) volume adjustment is
performed.
6. Press 
[ENTER]
 button, i-Bass f
0
 adjustment is performed.
7. To release this mode, pull out the AC cord. Then insert the AC
code, and press 
[POWER]
 button to turn the set ON. The cold
reset is enforced at the same time.
[PANEL TEST MODE ]
• This mode is used check operation of the front panel.
Procedure:
1. Press
X
button, 
[ENTER]
  button and 
[DISC2]
  button
simultaneously, all LED and segments in fluorescent indicator
tube are lighted up.
2. Press 
[ENTER]
  button and 
[DISC2]
  button simultaneously,
the key check mode is activated. In the key check mode, the
fluorescent indicator tube displays “KEY 0 0 0”. While pressing
the key, the number corresponding to each key is displayed.
Example: When 
[ENTER]
 button is pressed “KEY 0 2 0”
3. Press 
[ENTER]
  button and 
[DISC2]
  button simultaneously
again, the key control mode is activated. In the key control
mode, the fluorescent indicator tube displays “KEYCONT 0”.
4. Press 
[ENTER]
  button and 
[DISC2]
  button simultaneously
again, “VOLUME FLR” will be displayed.
When the 
[VOLUME]
 knob is turned clockwise, the message
“VOLUME UP” appears for two seconds, then the message
“VOLUME FLR” is displayed again.
When the 
[VOLUME]
 knob is turned counter-clockwise, the
message “VOLUME DOW” appears for two seconds, then the
message “VOLUME FLR” is displayed again.
5. Press 
[ENTER]
  button and 
[DISC2]
  button simultaneously
again, release from this mode.
[VERSION DISPLAY]
• This mode is used check the model, destination, software version.
Procedure:
1. Press
X
button, 
[ENTER]
  button and 
[DISC3]
  button
simultaneously, the model and destination are displayed.
2. Each time 
[ENTER]
  button and 
[DISC2]
  button is pressed
simultaneously, the display changes from MC version, GC
version and DVD version in this order, and release from this
mode.
3. When 
[ENTER]
  button and 
[DISC2]
  button is pressed
simultaneously while the version numbers are being displayed
except model and destination, the date of the software creation
appear. When 
[ENTER]
 button and 
[DISC2]
 button is pressed
simultaneously again, the display returns to the software
version display.
[COLD RESET]
• The cold reset clears all data stored in the RAM to initial condi-
tions. Execute this mode when returning the set to the customer.
Procedure:
1. Press
x
button, 
[ENTER]
  button,  and 
[DISC1]
  button
simultaneously.
2. The fluorescent indicator tube becomes blank for a while, and
the set is reset.