8. AUTOMATIC SELF-DIAGNOSIS FUNCTION
This test mode performs CREC and CPLAY automatically for mainly checking the characteristics of the optical pick-up.
To perform this test mode, the laser power must first be checked.
Perform AUTO CHECK after the laser power check and Iop Compare.
Procedure:
1. Press the
.
 “R”
or
>
 “R”
button to display “AUTO CHECK” (C01).
2. Press the
ENTER/YES “R”
button. If “LDPWR 
 ” is displayed, it means that the laser power check has not been performed. In
this case, perform the laser power check and Iop Compare, and then repeat from enter the MD test mode.
3. If a disc is in the mechanical deck, it will be ejected forcibly.
“DISC IN” will be displayed in this case. Load a test disc (MDW-74/GA-1) which can be recorded.
4. If a disc is loaded at step 3, the check will start automatically.
5. When “XX CHECK” is displayed, the item corresponding to XX will be performed.
When “06 CHECK” completes, the disc loaded at step 3 will be ejected. “DISC IN” will be displayed. Load the check disc (TDYS-1).
6. When the disc is loaded in step 5, the check will automatically be resumed from “07 CHECK”.
7. After completing to test item 12, check OK or NG will be displayed. If all items are OK, “CHECK ALL OK” will be displayed. If any item
is NG, it will be displayed as “NG:xxxx”.
When “CHECK ALL OK” is displayed, it means that the optical pick-up is normal. Check the operations of other parts (spindle motor,
sled motor, etc.).
When displayed as “NG:xxxx”, it means that the optical pick-up is faulty. In this case, replace the optical pick-up.
9. INFORMATION
Display the software version.
Procedure:
1. Press the
.
 “R”
or
>
 “R”
button to display “INFORMATION” (C31).
2. Press the
ENTER/YES “R”
button.
3. The software version will be displayed.
4. Press the
MENU/NO “R”
button to end this mode.
37
HCD-PX333
SECTION 5
ELECTRICAL ADJUSTMENTS
Other faults are suspected.
Check the mechanism parts (spindle motor, sled motor, etc.).
Start
NG
NG
NG
OK
OK
OK
Laser Power Check
6-2.
(See page 40)
6-3.
(See page 40)
6-4.
(See page 41)
Iop Compare
Auto Check
Replace optical pick-up or MDM-7X2A
MD  SECTION
Note 1:
About “R”
As this unit has only a few buttons, some operations require the use of remote commander (RM-S55EN/provided with unit: 1-476-664-21)
buttons. These operations are indicated as “R” in this manual.
Example:
MENU/NO “R”
...Press the 
[MENU/NO]
 button of the remote commander.
Note 2:
Incorrect operations may be performed if the MD test mode is not entered properly.
In this case, press the
?/1
button to turn the power off, and retry to enter the MD test mode.
1. PARTS  REPLACEMENT  AND  ADJUSTMENT
If malfunctions caused by optical pick-up such as sound skipping are suspected, follow the following check.
Check before replacement
38
HCD-PX333
6-4. Auto Check
(See page 41)
Start
YES
NO
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES
Replace IC195
Replace OP or IC195
Replace IC101, IC195, or D101
11. Iop NV SAVE (See page 44)
Replace OP, IC190, or IC195
Replace OP, IC102, IC190, 
or IC195
Replace OP, IC101, IC151, 
or IC195
Replace OP
Replace the spindle motor
End adjustments
After turning off and then on the power, 
initialize the EEPROM
For details, refer to “WHEN MEMORY NG IS DIS- 
PLAYED” in 1. SERVICING NOTES (See page 10)
• Abbreviation
OP: optical pick-up
7. INITIAL SETTING OF ADJUSTMENT VALUE 
(See page 43)
9. TEMPERATURE COMPENSATION OFFSET 
ADJUSTMENT (See page 43)
10. LASER POWER ADJUSTMENT (See page 43)
12. TRAVERSE ADJUSTMENT (See page 44)
13. FOCUS BIAS ADJUSTMENT (See page 45)
16. AUTO GAIN CONTROL OUTPUT LEVEL
ADJUSTMENT (See page 46)
“op change” in SELF-DIAGNOSIS FUNCTION
(ITEMS OF ERROR HISTORY MODE ITEMS 
AND CONTENTS) (See page 3)
8. RECORDING AND DISPLAYING THE IOP 
INFORMATION  (See page 43)
“spdl change” in SELF-DIAGNOSIS FUNCTION
(ITEMS OF ERROR HISTORY MODE ITEMS
AND CONTENTS) (See page 3)
Adjustment flow
39
HCD-PX333
2. PRECAUTIONS FOR CHECKING LASER DIODE
EMISSION
To check the emission of the laser diode during adjustments, never
view directly from the top as this may lose your eye-sight.
3. PRECAUTIONS FOR USE OF OPTICAL PICK-
UP (KMS-262A/262E)
As the laser diode in the optical pick-up is easily damaged by static
electricity, solder the laser tap of the flexible board when using it.
Before disconnecting the connector, desolder first. Before connecting
the connector, be careful not to remove the solder. Also take adequate
measures to prevent damage by static electricity. Handle the flexible
board with care as it breaks easily.
Optical pick-up flexible board
4. PRECAUTIONS FOR ADJUSTMENTS
1. When replacing the following parts, perform the adjustments
and checks with 
 in the order shown in the following table.
2. Set the MD test mode when performing adjustments.
After completing the adjustments, exit the MD test mode.
Perform the adjustments and checks in “Group Service” of the
MD test mode.
3. Perform the adjustments to be needed in the order shown.
4. Use the following tools and measuring devices.
Extension jig (27 core) (Part No. : J-2501-100-A)
CN102 on the BD (MD) board to CN1003 on the MD DIGITAL
board
Extension jig (17 core) (Part No. : J-2501-198-A)
CN103 on the BD (MD) board to CN1004 on the MD DIGITAL
board
Check Disc (TDYS-1) (Part No. : 4-963-646-01)
Test Disk (MDW-74/GA-1) (Part No. : 4-229-747-01)
Laser power meter LPM-8001 (Part No. : J-2501-046-A)
or
MD Laser power meter 8010S (Part No. :  J-2501-145-A)*
1
pick-up
flexible board
laser tap
• Oscilloscope (Measure after performing CAL of prove.)
• Digital voltmeter
• Thermometer
• Jig for checking BD (MD) board waveform
(Part No. : J-2501-196-A)
5. When observing several signals on the oscilloscope, etc.,
make sure that VC and ground do not connect inside the
oscilloscope.
(VC and ground will become short-circuited.)
6. Using the above jig enables the waveform to be checked without
the need to solder.
(Refer to Servicing Notes on page 9.)
7. As the disc used will affect the adjustment results, make sure
that no dusts nor fingerprints are attached to it.
*
1
Laser power meter
When performing laser power checks and adjustment (electrical
adjustment), use of the new MD laser power meter 8010S (Part
No. J-2501-145-A) instead of the conventional laser power
meter is convenient.
It sharply reduces the time and trouble to set the laser power
meter sensor onto the objective lens of optical pick-up.
7.
Initial setting of adjustment value
8.
Recording of Iop information
9.
Temperature compensation
offset adjustment
10. Laser power adjustment
11. Iop NV Save
12. Traverse adjustment
13. Focus bias adjustment
16. Auto gain adjustment
6-4. AUTO CHECK
Optical
Pick-up
IC101
IC102
IC151
IC190
IC195
D101
Parts to be replaced
Adjustment
Page of 110