Model
CMT-M90DVD HCD-M90
Pages
127
Size
14.08 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
cmt-m90dvd-hcd-m90.pdf
Date

Sony CMT-M90DVD / HCD-M90 Service Manual ▷ View online

25
HCD-M90
The following menus are normally not used.
3.
Track/Layer Jump
4.
Manual Adjustment
5.
Auto Adjustment
The persons who do not know well about these menus should not
use them.
6. Memory Check
EEPROM Data1
            -– DL –-
 CD LCD
SL
L0
L1
Focus Gain
xx xx
xx
xx
xx
TRK. Gain
xx xx
xx
xx
xx
FCS Balance
xx xx
xx
xx
xx
Focus Bias
xx xx
xx
xx
xx
TRV. Offset
xx xx
xx
xx
xx
L. F. Offset
xx xx
xx
xx
xx
EQ Boost
xx xx
xx
xx
xx
Mirror Time
xx xx
xx
xx
xx
_DOWN: Next Data
CLEAR: Default Set     page.1/2
EEPROM Data1
            -– DL –-
 CD LCD
SL
L0
L1
RF Jitter
xx --
xx
xx
xx
RF Level
xx --
xx
--
--
FE Level
xx --
xx
--
--
FE Balance
xx --
xx
--
--
TRV. Level
xx --
xx
--
--
Analog FRSW
xx xx
xx
xx
xx
PLL DacGain
xx xx
xx
xx
xx
_
 UP  : Prev Data
CLEAR: Default Set     page.2/2
This screen displays current servo adjusted data stored in the
EEPROM. Though adjusted data can be initialized with the
[CLEAR]
 key on the remote commander, they cannot be restored
after initialization. So, before clearing, make a note of the adjusted
data. For reference, the drive has been designed so that the gain
center value is 20 and offset value is 80. Other values will be in a
range of 10 to 80. If extreme value such as 00 or FF is set, adjustment
will be faulty. In such a case, check for disc scratch or cable
disconnection, then perform adjustment again.
Emergency History
### EMG. History ###
Laser Hours
CD xxxxxxxh
DVD xxxxxxxh
1.
00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
2.
00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
Select: 1 – 9 Scroll: UP/DOWN
(1: Last EMG.) Exit: RETURN
Press the  
[4]
 key on the remote commander of the emergency history
mode to display the servo error occurrence history. Press the  
M
or
m
keys on the remote commander to scroll the history data in the range
of the most recent error “1” to the error “10”. You can also type the
desired error number from the ten-keys on the remote commander.
The upper two columns show the accumulated turn-on hours of the
optical laser unit. The “minute” and the lower data are truncated.
Clearing the Error Histories
• Clearing the laser turn-on hours data
Press the 
[DVD DISPLAY]
 and 
[CLEAR]
 keys on the remote
commander in this order. Both of the CD laser data and DVD
laser data are cleared.
• Clearing the error occurrence history data
Press the 
[DVD TOP MENU]
 and 
[CLEAR]
 keys on the remote
commander in this order.
• Initializing the setups
Press the 
[DVD MENU]
  and 
[CLEAR]
  keys on the remote
commander in this order. When the message “Set Up Initialized”
is displayed, it indicates that the setups are initialized. The screen
returns to the EMG display screen soon.
How to Read the Eror Occurrence History Data
1
Emergency code No.
2
Not used (The codes that are used for debugging during program
design are displayed here. They are not related to the error occ
urrence history.)
3
Order of error occurrence (1 to 9)
Emergency Code Table
10.  Communication error with RF AMP (IC001) on the RF-240
board.
11.  Servo lock of focus, tracking and spindle servos are lost.
12.  Communication error with EEPROM (IC101) on the DVD
board.
13. Hours meter data write error in EEPROM (IC101) on the DVD
board.
14. Communication error with servo DSP (IC302) on the DVD
board or defective servo DSP
20. Tilt and sled servo initializing error. The laser unit does not
return to the initial position.
21. Tilt servo operation error.
22. The move request to illegal position is issued from system
control to the tilt servo.
23. Error in the tracking balance gain adjustment.
24. The move request to illegal position is issued from system
control to the sled servo.
30. Error in the tracking balance adjustment.
31. Error in the tracking gain adjustment.
32. Error in the focus balance adjustment.
33. Error in the focus bias adjustment.
34. Error in the focus gain adjustment.
35. Error in the tilt servo adjustment.
36. Error in the RF equalizer adjustment.
37. Error in the RF group delay adjustment
38. Amount of jitter upon completion of adaptation adjustment is
excessive.
40. Focus servo does not lock.
41. Focus jump is not possible with the dual layer (DL) disc.
50. CLV (spindle) servo does not lock.
51. Spindle does not stop.
60. The seek request to the non-existent address is issued from
system control using the DVD disc.
1.
3
1
2
2
Ver 1.1
26
HCD-M90
[DVD TRAY LOCK MODE]
• This mode is used to unable to take  sample disc out of tray in
the shop.
Procedure:
1. Press the
I/1
key to turn the power ON.
2. Press the 
[FUNCTION]
 key to select “DVD”.
3. While pressing the
x
key, press the
Z
 DVD
key.
4. The message “LOCKED” is displayed on the liquid crystal
display and the tray is locked. (Even if pressing the
Z
 DVD
key,
the message “LOCKED” is displayed on the liquid crystal
display and  the tray is locked)
6. To release from this mode, while pressing the
x
key,  press
the
Z
 DVD
key again.
7. The message “UNLOCKED” is displayed on the liquid crystal
display and the tray is unlocked.
[DVD COLOR SYSTEM NTSC]
• The color system can be changed over NTSC or PAL.
Procedure:
1. Press the
I/1
key to turn the power ON.
2. Press the 
[FUNCTION]
 key to select “DVD”.
3. While pressing the
x
key, press the
I/1
key.
4. Press the
I/1
key to turn the power ON. The color system is
changed over.
[TUNER  STEP  CHANGE]
• A step of AM channels can be changed over between 9 kHz and
10 kHz.
Procedure:
1. Press the
I/1
key to turn the power ON.
2. Press the 
[FUCTION]
  key to select “TUNER” and press the
[TUNER AM]
 key to turn the “AM”.
3. Press the
I/1
key to turn the set OFF.
4. While pressing 
[REPEAT/FM MODE]
 key, and press 
the I/1
key
and the display of  liquid crystal display changes to “AM 9K
Step” or “AM 10K Step”, and thus the channel step is changed
over.
27
HCD-M90
– DVD BOARD (Side A) –
RV501
Video Level
Adjustment
IC503
Note:
During diagnostic check, the characters and color bars can be seen
only with the NTSC monitor. Therefore, for diagnostic check, use
the monitor that supports both NTSC and PAL modes
Instruments required:
1) Color monitor TV
2) Oscilloscope 1 or 2 phenomena, band width over 100 MHz,
with delay mode
3) DVD reference disc
HLX-501 (J-6090-071-A) (dual layer) (NTSC)
HLX-503 (J-6090-069-A) (single layer) (NTSC)
HLX-504 (J-6090-088-A) (single layer) (NTSC)
HLX-505 (J-6090-089-A) (dual layer) (NTSC)
HLX-506 (J-6090-077-A) (single layer) (PAL)
HLX-507 (J-6090-078-A) (dual layer) (PAL)
VIDEO LEVEL ADJUSTMENT
<Purpose>
This adjustment is made to satisfy the NTSC/PAL standard, and if
not adjusted correctly, the brightness will be too large or small.
Signal
Color bars
Test point
VIDEO OUT jack
(75 
Ω terminated)
Instrument
Oscilloscope
Adjusting element
RV501 (DVD board)
Specified Value
1.0
+ 0.04
 Vp-p
– 0.02
Procedure:
1. Press the
I/1
key to turn the power on, and turn the
[FUNCTION]
 key to select “DVD”.
2. Adjust the RV501 on the MB board to attain 1.0
+ 0.04
 Vp-p.
– 0.02
Figure 5-1
CHECKING S VIDEO OUTPUT S-Y
<Purpose>
Check S-terminal video output.  If it is incorrect, pictures will not
be displayed correctly in spite of connection to the TV with a S-
terminal cable.
Signal
Color bars
Test point
S VIDEO OUT (S-Y) jack
(75 
Ω terminated)
Instrument
Oscilloscope
Specified Value
1.0 
± 0.05 Vp-p
Procedure:
1. Press the
I/1
key to turn the power ON, and turn the
[FUNCTION]
 key to select “DVD”.
2. Confirm that the S-Y level is 1.0 
± 0.05 Vp-p.
Figure 5-2
CHECKING S VIDEO OUTPUT S-C
<Purpose>
This checks whether the S-C satisfies the NTSC Standard.  If it is
not correct, the colors will be too dark or light.
Signal
Color bars
Test point
S VIDEO OUT (S-C) jack
(75 
Ω terminated)
Instrument
Oscilloscope
Specified Value
286 
± 30 mVp-p (NTSC)
300 
± 100 mVp-p (PAL)
Procedure:
1. Press the
I/1
key to turn the power ON, and turn the
[FUNCTION]
 key to select “DVD”.
2. Confirm that the S-C burst is 286 
± 30 mVp-p (NTSC) or 300
± 100 mVp-p (PAL).
Figure 5-3
Adjustment Location :
SECTION  5
ELECTRICAL  ADJUSTMENTS
1.0
+ 0.04
 Vp-p
– 0.02
1.0 
±
 0.05 Vp-p
286 
±
 50 mVp-p
(NTSC)
or
300 
±
 100 mVp-p
(PAL)
DVD  SECTION
28
HCD-M90
Note:
Confirm each contents of this section first of all. If the results are
not satisfied, do the adjustment.
1. The adjustments should be performed with the rated power supply
voltage unless otherwise noted.
2. The adjustments should be performed in the order given in this service
manual.
3. The adjustments should be performed for both L-CH and R-CH.
REC BIAS ADJUSTMENT
Procedure:
1. Mode: REC
FUNCTION: MD
2. Mode: Playback
3. Confirm playback the signal recorded in step 1 become speci-
fied values as follows.
If these values are out of specification values, adjust the RV101
(L-CH) and RV201 (R-CH) on the TC board to repeat steps
1and 2.
Specified values: Playback output of 315 Hz to playback
output of 10 kHz: 
± 0.5 dB
Adjustment Location: TC board
attenuator
set
MAIN board 
AUDIO IN (MD/VIDEO) jack (SJ302)
L-CH, R-CH
1) 315 Hz
2) 10 kHz
50 mV (– 23.8 dB)
600 
blank tape
CN-123
AF OSC
+
set
recorded
portion
MAIN board
SPEAKER terminals (SJ301)
L-CH, R-CH
level meter
0 dB=0.775 V
DECK  SECTION
RV101 (L)
RV201 (R)
REC Bias
Adjustment
– TC BOARD (Component Side) –
Page of 127