Sony CMT-M333NT / HCD-M333 Service Manual ▷ View online

9
HCD-M333
Disc Tray Lock
The disc tray lock function for the antitheft of a demonstration disc in the store is equipped.
Procedure:
1.
Press the  ?/1  button to turn the set on.
2.
Select the function “CD”.
3.
A disc is put in and a tray is closed.
4.
Press two buttons of  x  and  Z  (CD) simultaneously for five seconds.
5.
The message “LOCKED” is displayed and the tray is locked. (Even if turning power on/off, the tray is still locked.)
6.
Press two buttons of  x  and  Z  (CD) simultaneously for five seconds again.
7.
The message “UNLOCKED” is displayed and the tray is unlocked.
Service Position-1 (Checking TC Section)
Under such a position, please do the following confirmation.
Checking the earth from the TC board to the chassis
With this unit, when playing back the cassette tape and turning up the volume while the earth connection of the TC board is detached from the
chassis, oscillation may occur and the tweeter may be damaged.
Therefore, check that the earth is securely connected to the chassis after repair.
SECTION 1
SERVICING NOTE
Note 1:
About “R”
As this unit has only a few buttons, some operations require the use of remote commander (RM-SM100W/provided with unit)  buttons. These
operations are indicated as “R” in this manual.
Example:  MENU/NO “R”  ...Press the  MENU/NO  button of the remote commander.
Note 2:
Incorrect operations may be performed if the test mode is not entered properly.
In this case, press the  ?/1  button to turn the power off, and retry to enter the test mode.
Note 3:
If the disc tray does not open and the message “LOCKED” appears, press the two buttons of  
x
  and  Z  (CD)  at the same for
5 seconds or longer.
Then the lock is released, the message “UNLOCKED” appears for 2 seconds and the disc tray opens.
Ver. 1.7
MAIN BOARD
TC BOARD
*
 
earth wire
*
 
earth terminal
cassette mechanism deck
(CMAL1Z-233A)
*
 
Either an earth wire or an earth terminal is attached.
10
HCD-M333
Earth Wire Type
1.
If an earth wire is attached
1-1. The wire must be clipped securely on the chassis. (fig 3)
1-2. The screw on the cassette mechanism deck must be securely
tightened. (fig 2)
1-3. The wire must not be broken. (fig 2)
Earth Terminal Type
2.
If an earth terminal is attached
2-1. The screw for the earth terminal on the TC board must be
securely tightened. (fig 5)
2-2. The jumper chip (C648) next to the earth terminal must be
securely attached. (fig 6)
Ver. 1.7
The screw must be securely tightened.
The wire must not be broken.
fig1 : Attaching position of the earth wire (TC side)
fig2 : Close up the earth wire 
fig3 : exterior the earth wire 
The earth wire must be
securely connected.
fig4 : Position of the earth terminal
fig5 : Close up the earth terminal
fig6 : The earth terminal pattern face
The screw must
be securely
tightened.
C648 CHIP
JUMPER
must be
securely
attached.
Earth terminal
Earth 
terminal
11
HCD-M333
Service Position-2 (Checking CD Mechanism and MD Mechanism Section)
Service Position-3 (Checking Power Supply Section)
Connect the POWER board (CN985) and the AMP board (CN805) with the extension cable (6P)(J-2501-229-A).
MAIN BOARD
MD DIGITAL BOARD
MD mechanism deck section
(MDM-7S2D)
CD mechanism deck section
(CDM55A-30BBD6)
MAIN BOARD
POWER BOARD
jig (6P) (J-2501-229-A)
AMP BOARD
REG BOARD
12
HCD-M333
Jig For Checking BD (MD) Board Waveform
The special jig (J-2501-196-A) is useful for checking the waveform of the BD (MD) board. The names of terminals and the checking items
to be performed are shown as follows.
I+3V : For measuring Iop (Check the deterioration of the optical pick-up laser)
Iop
: For measuring Iop (Check the deterioration of the optical pick-up laser)
GND : Ground
TE
: TRK error signal (Traverse adjustment)
FE
: Focus error signal
VC
: Reference level for checking the signal
RF
: RF signal (Check jitter)
I+3V
CN105
Iop
TE
VC
GND
FE
RF
I+3V
Iop
GND
TE
FE
VC
RF
I+3V
Iop
GND
TE
FE
VC
RF
1
7
for MDM-7S2D
Page of 113
Display

Click on the first or last page to see other CMT-M333NT / HCD-M333 service manuals if exist.