36
HCD-M10
7. INITIAL  SETTING  OF  ADJUSTMENT  VALUE
Note:
Mode which sets the adjustment results recorded in the non-volatile
memory to the initial setting value. However the results of the tempera-
ture compensation offset adjustment will not change to the initial setting
value.
If initial setting is performed, perform all adjustments again excluding the
temperature compensation offset adjustment.
For details of the initial setting, refer to “4. Precautions for Adjustments”
(See page 32) and execute the initial setting before the adjustment as re-
quired.
Procedure:
1. Press the
“R” or
>
 
“R” button to display “ADJ
CLEAR”  (C28).
2. Press the ENTER/YES “R” button.  “Complete!” will be
displayed momentarily and initial setting will be executed, after
which “ADJ CLEAR” (C28) will be displayed.
8. RECORDING  AND  DISPLAYING  THE  Iop
INFORMATION
The Iop data can be recorded in the non-volatile memory. The Iop
value on the optical pick-up label and the Iop value after the
adjustment will be recorded. Recording these data eliminates the
need to read the label on the optical pick-up.
Recording Procedure:
1. Press the
“R” or
 >
 
“R” button to display “Iop Write”
(C05), and press the ENTER/YES “R” button.
2. The display becomes “Ref=@@@.@” (@ is an arbitrary
number) and the numbers which can be changed will blink.
3. Input the Iop value on the optical pick-up label.
To select the number : Press the
“R” or
 >
 
“R” button.
To select the digit : Press the  REC MODE  button.
4. When the ENTER/YES “R” button is pressed, the display
becomes “Measu=@@@.@” (@ is an arbitrary number).
5. As the adjustment results are recorded for the step 4 value. Leave
it as it is and press the ENTER/YES “R” button.
6. “Complete!!” will be displayed momentarily. The value will be
recorded in the non-volatile memory and the display will become
“Iop Write” (C05).
Display Procedure:
1. Press the
“R” or 
 >
 
“R” button to display “Iop Read”(C26).
2. Press the ENTER/YES “R” button.
3. “@@.@/##.#” is displayed and the recorded contents are
displayed.
@@.@ indicates the Iop value on the optical pick-up label.
##.# indicates the Iop value after adjustment
4. To end, press the MENU/NO “R” button to display “Iop Read”
(C26).
9. TEMPERATURE COMPENSATION OFFSET
ADJUSTMENT
Save the temperature data at that time in the non-volatile memory
as 25 ˚C reference data.
Note:
1. Usually, do not perform this adjustment.
2. Perform this adjustment in an ambient temperature of 22 ˚C to 28 ˚C.
Perform it immediately after the power is turned on when the internal
temperature of the unit is the same as the ambient temperature of 22 ˚C
to 28 ˚C.
3. When D101 has been replaced, perform this adjustment after the tem-
perature of this part has become the ambient temperature.
Procedure:
1. Press the
“R” or
  >
 
“R” button to display “TEMP
ADJUST” (C03).
2. Press the ENTER/YES “R” button to select the “TEMP
ADJUST” mode.
3. “TEMP = 
 [OK]” and the current temperature data will be
displayed.
4. To save the data, press the ENTER/YES “R” button.
When not saving the data, press the MENU/NO “R” button.
5. When the ENTER/YES “R” button is pressed, “TEMP = 
SAVE” will be displayed and turned back to “TEMP ADJUST”
(C03) display then.
Specified Value:
The “TEMP =  
” should be within “E0 - EF”, “F0 - FF”, “00 -
0F”,  “10 - 1F” and “20 - 2F”.
10. LASER POWER ADJUSTMENT
Before starting adjustment;
Check the Iop value of the optical pick-up before adjustments.
(Refer to 8. Recording and Displaying the Iop Information)
Connection:
Procedure:
1. Insert the laser power meter probe into the disk insertion slot
and set it on top of the objective lens of the optical pick-up.
(When it cannot be set properly, press the
m
 
 button or
M
button to move the optical pick-up)
Connect the digital voltmeter to CN105 pin 1 (I+3V) and
CN105pin 2 (Iop) on the BD board.
2. Press the
“R” or
  >
 
“R” button to display “LDPWR
ADJUST” (C04).
(Laser power : For adjustment)
3. Press the ENTER/YES “R” button once to display “L 0.9 mW
”.
4. Press the
“R” or 
 >
 
“R” button until the laser power
meter reading matches with the specified value.
Press the ENTER/YES “R” button after setting the range knob
of the laser power meter to 10mW, and save the adjustment
results. (“LD SAVE $ 
” will be displayed for a moment)
5. Then “L 7.0 mW $ 
” will be displayed.
Optical pick-up
objective lens
laser
power meter
+
BD board
digital voltmeter
CN105 pin 
1
 (I+3V)
CN105 pin 
2
 (Iop)
37
HCD-M10
6. Press the
“R” or 
  >
 
“R” button so that the reading
of the laser power meter becomes the specified value, press
the ENTER/YES “R” button to save it.
Note:
Do not perform the emission with 7.0 mW more than 15 seconds
continuously.
7. Then,press the
.
 
“R” or
  >
 
“R” button to display
“LDPWR CHECK” (C13).
8. Press the ENTER/YES “R” button once to display “L 0.9mW$
”. Check that the reading of the laser power meter matches
with the specified value.
9. Press the ENTER/YES “R” button once more to display “L
7.0mW$ 
”. Check that the reading the laser power meter and
digital voltmeter satisfy the specified value.
Note down the digital voltmeter reading value.
Specified Value:
Laser power meter reading :
Digital voltmeter reading
: Value on the optical pick-up label 
±
10%
10. Press the MENU/NO “R” button to display “LDPWR CHECK”
(C13) and stop the laser emission.
(The MENU/NO  “R” button is effective at all times to stop
the laser emission)
11. Press the
“R” or 
 >
 
“R” button to display “Iop Write”
(C05).
12. Press the ENTER/YES “R” button. When the display becomes
Ref=@@@.@ (@ is an arbitrary number), press the ENTER/
YES  “R” button to display “Measu=@@@.@” (@ is an
arbitrary number).
13. The numbers which can be changed will blink. Input the Iop
value noted down at step 9.
To select the number : Press the
“R” or 
 >
 
“R”  button.
To select the digit
: Press the  REC MODE  button.
14. When the ENTER/YES “R” button is pressed, “Complete!” will
be displayed momentarily. The value will be recorded in the non-
volatile memory and the display will become “Iop Write” (C05).
Note:
After step 4, each time the ENTER/YES “R” button is pressed,
the display will be switched to “L 0.7mW$ 
”,  “L 6.2mW$ 
Nothing needs to be performed here.
12. TRAVERSE ADJUSTMENT
Connection:
Procedure:
1. Connect an oscilloscope to CN105 pin 4 (TE) and CN105 pin
6
 (VC) on the BD board.
2. Load a disc (any available on the market). (Refer to Note 1)
3. Press the
M
 
button to move the optical pick-up outside the
pit.
4. Press the
“R” or
>
 
“R” button to display “EF MO
ADJUST” (C07).
5. Press the ENTER/YES “R” button to display “EFB = 
 MO-R”.
(Laser power READ power/Focus servo ON/tracking servo
OFF/spindle (S) servo ON)
6. Press the
“R” or
>
 
“R” button so that the waveform
of the oscilloscope becomes the specified value.
(When the
“R” or
>
 
“R” button  is pressed, the 
 of
“EFB= 
” changes and the waveform changes) In this adjustment,
waveform varies at intervals of approx. 2%. Adjust the waveform
so that the specified value is satisfied as much as possible.
(Read power traverse adjustment)
Traverse Waveform
Note 1:
Data will be erased during MO reading if a recorded disc is
used in this adjustment.
Note 2:
If the traverse waveform is not clear, connect the oscilloscope
as shown in the following figure so that it can be seen more
clearly.
KMS260E
20101
H0576
lop=57.6 mA in this case
lop (mA) = Digital voltmeter reading (mV)/1 (
)
(Optical pick-up label)
For details of the method for
checking this value, refer to 
“8. Recording and Displaying
the Iop Information”
+
oscilloscope
(DC range)
V: 0.1 V/div
H: 10 ms/div
BD board
CN105 pin 
4
 (TE)
CN105 pin 
6
 (VC)
A
B
VC
Specification A = B
11. Iop NV SAVE
Write the reference values in the nonvolatile memory to perform
“Iop compare”. As this involves rewriting the reference values, do
not perform this procedure except when adjusting the laser power
during replacement of the optical pick-up and when replacing the
IC102. Otherwise the optical pick-up check may deteriorate.
Note:
 Perform this function with the optical pick-up set at room temperature.
Procedure:
1. Press the
“R” or 
 >
 
“R” button to display “Iop NV Save”
(C06).
2. Press the ENTER/YES “R” button and display “Iop [stop]”.
3. After the display changes to “Iop =
save?”, press the ENTER/
YES “R” button.
4. After “Complete!” is displayed momentarily, the display changes
to “Iop 7.0 mW”.
5. After the display changes to “Iop=
save?”, press the  ENTER/
YES “R” button.
6. When “Complete!” is displayed, it means that Iop NV saving
has been completed.
+
oscilloscope
(DC range)
10 pF
330 k 
CN105 pin 
4
 (TE)
CN105 pin 
6
 (VC)
BD board
SPECIFIED VALUE
L 0.9 mW
L 7.0 mW
0.80 to 0.96 mW
6.90 to 7.10 mW
7. Press the ENTER/YES  “R” button and save the result of
adjustment to the non-volatile memory (“EFB = 
 SAVE” will
be displayed for a moment. Then “EFB = 
 MO-W” will be
displayed).
38
HCD-M10
8. Press the
“R” or
 >
 
“R” button so that the waveform
of the oscilloscope becomes the specified value.
(When the
“R” or
>
 
“R” button is pressed, the 
 of
“EFB= 
” changes and the waveform changes) In this
adjustment, waveform varies at intervals of approx. 2%. Adjust
the waveform so that the specified value is satisfied as much as
possible.
(Write power traverse adjustment)
Traverse Waveform
9. Press the ENTER/YES “R” button, and save the adjustment
results in the non-volatile memory. (“EFB = 
 SAVE” will be
displayed for a moment)
10. “EFB = 
 MO-P” will be displayed.
The optical pick-up moves to the pit area automatically and
servo is imposed.
11. Press the
.
 
“R” or
>
 
“R” button until the waveform of
the oscilloscope moves closer to the specified value.
In this adjustment, waveform varies at intervals of approx. 2%.
Adjust the waveform so that the specified value is satisfied as
much as possible.
Traverse Waveform
12. Press the ENTER/YES “R” button, and save the adjustment
results in the non-volatile memory. (“EFB = 
 SAVE” will be
displayed for a moment)
Next  “EF MO ADJUST” (C07) is displayed. The disc stops
rotating automatically.
13. Press the  Z  MD  button and take out the disc.
14. Load the check disc (TDYS-1).
15. Press the
.
 
“R” or
  >
 
“R” button to display “EF CD
ADJUST” (C08).
16. Press the ENTER/YES “R” button to display “EFB = 
 CD”.
Servo is imposed automatically.
17. Press the
“R” or
>
 
“R” button so that the waveform
of the oscilloscope moves closer to the specified value.
In this adjustment, waveform varies at intervals of approx. 2%.
Adjust the waveform so that the specified value is satisfied as
much as possible.
Traverse Waveform
18. Press the ENTER/YES “R” button, display “EFB = 
 SAVE”
for a moment and save the adjustment results in the non-volatile
memory.
Next “EF CD ADJUST” (C08) will be displayed.
19. Press the  Z  MD  button and take out the  check disc.
Adjustment Location: BD board (see page 40)
13. FOCUS BIAS ADJUSTMENT
Procedure:
1. Load the check disc (MDW-74/GA-1).
2. Press the
“R” or
>
 
“R” button to display “CPLAY1
MODE” (C34).
3. Press the ENTER/YES “R” button to display “CPLAY 1MID”.
4. Press the MENU/NO “R” button when “C = 
 AD = 
)”
is displayed.
5. Press the
“R” or
>
 
“R” button to display “FBIAS
ADJUST” (C09).
6. Press the ENTER/YES “R” button to display “
/
 a = 
T”.
The first four digits indicate the C error rate, the two digits
after “/ ” indicate ADER, and the 2 digits after “a =” indicate
the focus bias value.
7. Press the 
 >
 
“R” button and find the focus bias value at which
the C error rate becomes about 200 (refer to Note 2).
8. Press the ENTER/YES “R” button to display “
/
 b =
 T”.
9. Press the
“R” button and find the focus bias value at which
the C error rate becomes about 200.
10. Press the ENTER/YES “R” button to display “
/
 c = 
T”.
11. Check that the C error rate is below 20 and ADER is 00. Then
press the ENTER/YES “R” button.
12. If the “(
)” in “
 - 
 - 
 (
)” is above 20, press the ENTER/
YES “R”  button.
If below 20, press the MENU/NO “R” button and repeat the
adjustment from step 2.
13. Press thet  Z  MD  button and take out the disc.
Note 1:
The relation between the C error and focus bias is as shown in
the following figure. Find points A and B in the following figure
using the above adjustment. The focal point position C is auto-
matically calculated from points A and B.
Note 2:
As the C error rate changes, perform the adjustment using the
average vale.
A
B
VC
Specification A = B
A
B
VC
Specification A = B
A
B
VC
Specification A = B
C error
about 
200
B
C
A
Focus bias value
39
HCD-M10
14. ERROR RATE CHECK
14-1. CD Error Rate Check
Procedure:
1. Load the check disc (TDYS-1).
2. Press the
“R” or
>
 
“R” button and display “CPLAY1
MODE” (C34).
3. Press the ENTER/YES “R” button twice and display “CPLAY1
MID”.
4. The display changes to “C = 
 AD =_ _)”.
5. Check that the C error rate is below 20.
6. Press the MENU/NO “R” button to stop playback, then press
the   Z  MD  button and take out the check disc.
14-2. MO Error Rate Check
Procedure:
1. Load the continuously-recorded disc.  (Refer to “5.  USING
THE CONTINUOUSLY RECORDED DISC” (See page 33))
2. Press the
“R” or
  >
 
“R” button to display “CPLAY1
MODE” (C34).
3. Press the ENTER/YES “R” button to display “CPLAY1MID”.
4. The display changes to “C = 
 AD = 
)”.
5. If the C error rate is below 20, check that ADER is 00.
6. Press the MENU/NO “R” button to stop playback, then press
the   Z MD  button and take out the disc.
15. FOCUS BIAS CHECK
Change the focus bias and check the focus tolerance amount.
Procedure:
1. Load the continuously-recorded disc.  (Refer to “5.  USING
THE CONTINUOUSLY RECORDED DISC” (See page 33))
2. Press the
“R” or
>
 
“R” button to display “CPLAY1
MODE” (C34).
3. Press the ENTER/YES “R” button twice to display “CPLAY1
MID”.
4. Press the MENU/NO “R” button when “C = 
 AD = 
)”
is displayed.
5. Press the
“R” or
>
 
“R” button to display “FBIAS
CHECK” (C16).
6. Press the ENTER/YES “R” button to display “
/
 c = 
”.
The first four digits indicate the C error rate, the two digits after
“/  ” indicate ADER, and the 2 digits after “c =” indicate the
focus bias value.
7. Press the ENTER/YES “R” button and display “
/
 b =
”.
Check that the C error is below 220 and ADER is below 2.
8. Press the ENTER/YES “R” button and display “
/
 a =
”.
Check that the C error is below 220 and ADER is below 2
9. Press the MENU/NO “R” button, then press the  Z  MD  button
and take out the disc.
Note:
If the C error and ADER are above other than the specified value
at points a (step 8. in the above) or b (step 7. in the above), the
focus bias adjustment may not have been carried out properly.
Adjust perform the beginning again.
16. AUTO  GAIN  CONTROL  OUTPUT  LEVEL
ADJUSTMENT
Be sure to perform this adjustment when the optical pick-up is
replaced.
If the adjustment results becomes “Adjust NG!”, the optical pick-
up may be faulty or the servo system circuits may be abnormal.
16-1. CD Auto Gain Control Output Level Adjustment
Procedure:
1. Load the check disc (TDYS-1).
2. Press the
. m
 
“R” or
M >
 
“R” button to display “AG
Set (CD)” (C11).
3. When the ENTER/YES “R” button is pressed, the adjustment
will be performed automatically.
“Complete!” will then be displayed momentarily when the value
is recorded in the non-volatile memory, after which the display
changes to “AG Set (CD)” (C11).
4. Press the  Z  MD  button and take out the check disc.
16-2. MO Auto Gain Control Output Level Adjustment
Procedure:
1. Load the test disc (MDW-74/GA-1).
2. Press the
“R” or  
>
 
“R” button to display “AG Set
(MO)” (C10).
3. When the ENTER/YES “R” button is pressed, the adjustment
will be performed automatically.
“Complete!” will then be displayed momentarily when the value
is recorded in the non-volatile memory, after which the display
changes to “AG Set (MO)” (C10).
4. Press the  Z  MD  button and take out the test disc.
Page of 92