HCD-HPX11D
4-12. ASSEMBLING OF THE SUB GEAR (2 STEP)
1
 sub gear (2 step)
gear (sub gear pin right)
gear (sub gear pin right)
5
 two screws (M2
 
×
 5)
6
 
arm section
4
 k tapping screw (2.6
 
×
 8)
3
 cover (R)
PRECAUTION DURING SUB GEAR (2 STEP) INSTALLATION
hole
hole
hole
sub gear (2 step)
2
 
Align the sub gear (2 step) and 
     the gear (sub gear pin right) hole.
54
HCD-HPX11D
4-13. CONFIRMING THE ASSEMBLING OF THE ARM SECTION
1
 Release the lock of the sub slider assy 
     and slide it in the direction of the arrow.
4
 Slide the stocker assy in the 
     direction of the arrow.
5
 Push the sub slider 
     assy into the end of 
     the arm (R).
3
 Check point 2: 
     All the stocker assy is standing.
6
 Check point 3: 
     Two parts of the stopper 
     touch the stock base (B).
stock base (B)
Note. 
If the two parts of the stopper do not touch the stock base (B) when 
the sub slider assy is pushed to the end, the phases are not correctly 
adjusted. Reassemble the assy.
UPPER
SIDE
2
 Check point 1: 
     The smooth movement of 
     this part when sliding.
55
HCD-HPX11D
SECTION 5
TEST MODE
[Cold Reset]
The cold reset clears all data including preset data stored in
the RAM to initial conditions. Execute this mode when
returning the set to the customer.
Procedure:
1. Press  ?/1  button to turn the set ON.
2. Press three buttons x  ,  DIRECTION , and ?/1
simultaneously.
3. The fluorescent indicator tube does not display any message
and the set is reset.
[Tuner Step Change]
A step of AM channels can be changed over between 9 kHz
and 10 kHz.
Procedure:
1. Press  ?/1  button to turn the set ON.
2. Select the function “TUNER”, and press  TUNER/BAND
button to select the BAND “AM”.
3. Press  ?/1  button to turn the set OFF.
4. Press  +ML  and  ?/1  buttons simultaneously, and the
display of fluorescent indicator tube changes to “STEP  9” or
“STEP  10”, and thus the channel step is changed over.
[Function Change]
Change of function VIDEO or MD (also the input level
changes).
Procedure:
1. Press  ?/1  button to turn the set ON.
2. Press  FUNCTION  and  ?/1  buttons simultaneously, and
the display of fluorescent indicator tube changes to “MD” or
“VIDEO”, and thus the channel step is changed over.
3. Press  ?/1  button to turn the set OFF.
[DISC TRAY  LOCK]
   The disc tray lock function for the antitheft of a demonstration
disc in the store is equipped.
Setting Procedure :
1. Press the   ?/1  button to turn the set on.
2. Press two buttons of  x    and  Z    simultaneously for five
seconds.
3. The message “LOCKED” is displayed and the tray is locked.
Releasing Procedure :
1. Press two buttons of  x    and  Z    simultaneously for five
seconds.
2. The message “UNLOCKED” is displayed and the tray is
unlocked.
   Note :
When “LOCKED” is displayed, the tray lock is not released by
turning power on/off with  `/1  button.
[COMMON (MC) Test Mode]
This mode is used to check operations of the respective sections
of Amplifier, Tuner, and Tape.
Procedure:
To enter COMMON (MC) Test Mode
1. Press   ?/1  button to turn on the set.
2. Press the three buttons of  x  ,   DIRECTION  and  DSGX
simultaneously.
3. When  VOLUME  control knob is turned clockwise even
slightly, the sound volume increases to is maximum and a
message “VOLUME MAX” appears for two seconds, then
the display returns to the original display.
4. When  VOLUME  control knob is tuned counter-clockwise
even slightly, the sound volume decreases to its minimum and
a message “VOLUME MIN” appears for two seconds, then
the display returns to the original display.
5. When you press the  EQ EDIT  button, the message “GEQ
MAX” is displayed and the entire band of the graphic equalizer
is set to the maximum level.
6. When you press the  EQ EDIT  button, the message “GEQ
MIN” is displayed and the entire band of the graphic equalizer
is set to the minimum level.
7. When you press the  EQ EDIT  button, the message “GEQ
FLT” is displayed and the entire band of the graphic equalizer
is set to the center level.
8. When you want to exit this mode, press  ?/1  button.
9. The cold reset is enforced at the same time.
[Color System Change]
Procedure:
1. Press  ?/1  and  EX-CHANGE  buttons simultaneously, and
the display of fluorescent indicator tube changes to “COL
PAL” or “COL  NTSC”, and the color system is changed over.
[DVD and CD Ship Mode (No Memory Clear)]
This mode moves the position to the position durable to vibra-
tion Use this mode when returning the set to the customer
after repair.
Procedure:
1. Press  ?/1  button to turn the set ON.
2. Press three buttons  x  ,  ECHO  and  ?/1  simultaneously.
3. After the “STANBY” display blinks six times, a message
“LOCK” is displayed on the fluorescent indicator rube, and
the DVD ship mode is set.
[DVD and CD Ship Mode (Memory Clear)]
This mode moves the pick-up to the position durable to vibra-
tion. Use this mode when returning the set to the customer
after repair.
Procedure:
1. Press  ?/1  button to turn the set ON.
2. Press three buttons  DSGX  ,  DVD/u    , and  EQ EDIT
simultaneously.
3. After the “STANDBY” display blinks six times, a message
“LOCK” is displayed on the fluorescent indicator tube, and
the DVD ship mode is set.
Ver. 1.3
56
HCD-HPX11D
[Version Test  Mode]
Procedure:
1. When the panal test mode is activated, press the  EQ EDIT
button and the model name and destination is displayed one
after the other.
2. Whenever press the  EQ EDIT +  button, the version is
displayed in order of MC, GC, ST, TA, TM, TC and DVD.
3. Press the  EQ EDIT -  button and the date of the software
production is displayed.
4. Press the  EQ EDIT -  button again and the version is displayed.
5. To exit from this mode, press three buttons  x  ,  DSGX  and
ECHO  simultaneously.
[PANEL Test  Mode]
This mode is used to check the version, FL tube, LED and
keyboard.
Enter the panel test mode.
Procedure:
1. Press  ?/1  button to turn the set ON.
2. Press three buttons  x  ,  DSGX  , and  ECHO  simultaneously.
3. LEDs and fluorescent indicator tube are all turned on.
[Key Test  Mode]
Procedure:
1. When the panel test mode is activated, press the  DIRECTION
button, to select the key test mode. In the key check mode, the
fluorecent indicator displays “K 0  V0”. Each time a button is
pressed, “K” value increases. However, once a button is
pressed, it is no longer taken into account. When all keys are
pressed correctly, “K25  V0” is displayed.
2. To exit from this mode, press three buttons  x  ,  DSGX  and
ECHO  simultaneously.
[DVD Power Manage]
Procedure:
1. Press the  ?/1  button to turn the set on.
2. Select the FUNCTION to DVD.
3. Press the  ?/1  button to turn off the main power.
4. While depressing the  x  button, press the  ?/1  button.
5. The message “DVD POWER OFF” is displayed.
6. Press the  ?/1  button to turn off the main power.
7. Repeat step 1 to 4.
8. The message “DVD POWER ON” is displayed.
[DVD Service Mode]
Procedure:
1. Press the  ?/1  button on the main unit.
2. Set the FUNCTION to DVD.
3. Press two buttons of  Z  and  x   simultaneously.
4. When  VOLUME  control knob is turned clockwise.
The message “SERVICE IN” is displayed on the display. The
Test Mode Menu is displayed.
5. To execute each function, select the number on the remote
commander.
6. See the following section for explanation in detail.
7. To exit from this mode, press the  ?/1  button.
[REPEAT 5 LIMIT OFF MODE]
This mode is used to enable infinite repetitions. Normally, the
number of repetitions allowed is 5.
Procedure:
1. Press the  ?/1  button to turn the set on.
2. Select the FUNCTION to DVD.
3. Press three buttons  DISC SKIP  ,  x    and  ECHO
simultaneously.
4. Infinited repetitions is enable.
Ver. 1.3
Page of 127
Display