DOWNLOAD Sony CMT-GP6V / HCD-GP6V Service Manual ↓ Size: 5.04 MB | Pages: 57 in PDF or view online for FREE

Model
CMT-GP6V HCD-GP6V
Pages
57
Size
5.04 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
cmt-gp6v-hcd-gp6v.pdf
Date

Sony CMT-GP6V / HCD-GP6V Service Manual ▷ View online

13
HCD-GP6V
4
two floating screws
     (+PTPWH M2.6)
3
two floating screws
     (+PTPWH M2.6)
1
floating screws
     (+PTPWH M2.6)
2
5
BU holder (BU-30)
7
two insulators
6
two insulators
base unit
(BU-30BD61S)
8
wire (flat type) 9p (CN105)
3-11. BASE UNIT (BU-30BD61S)
14
HCD-GP6V
[Cold Reset]
The cold reset clears all data including preset data stored in
the RAM to initial conditions. Execute this mode when re-
turning the set to the customer.
Procedure:
1. Press the "/1 button to turn off the main power.
2. While depressing the  x  button, press the "/1 button.
3. The fluorescent indicator tube does not display any message
and the set is reset.
[Fluorescent Indicator Tube Test Mode]
Fluorescent segments are tested when this test is activated.
Procedure:
1. Extract an AC plug.
2. While depressing the  CD u  button, insert an AC plug.
3. All segments of the fluorescent indicator tube turn on.
4. CD test mode is activated.
5. To exit from this mode, press the "/1 button or disconnect the
power cord.
[Version Display Mode]
The model and the version are displayed.
Procedure:
1. Press the "/1 button to turn the set on.
2. To enter the test mode, press two buttons  x  and "/1 simulta-
neously for more than five seconds. The model and the ver-
sion are displayed.
[AMP Test]
This mode is used to check the function of the amplifier.
Procedure:
1. Extract an AC plug.
2. While depressing the [MD] button, insert an AC plug to enter
the AMP test mode. The message “AMP TEST” is displayed.
3. The message “Volume MAX” is displayed, when pressing the
[VOLUME +] button. The message “Volume MIN” is displayed,
when pressing the [VOLUME --] button.
4. Each time pressing the [PLAY MODE/TUNING MODE] button,
the message “EQ MAX”, “EQ MIN” or “EQ FLAT” is dis-
played in this order.
5. To release from this mode, disconnect the AC plug and turn
the power off.
[AM Channel Step 9 kHz/10kHz Selection Mode]
Either the 9 kHz step or 10 kHz step can be selected for the
AM channel step.
Procedure:
1. Set the function to AM.
2. While depressing the [TUNER/BAND]  button, press the "/1
button.
3. The channel step is changed over.
[TC Test  Mode]
Procedure:
1. Extract an AC plug.
2. While depressing the  TAPE nN  button, insert an AC plug.
3. The message “TC TEST” is displayed and TC test mode is
activated.
Zero Return
1. Press the + > M  or  – .m  button.
2. The tape is rewound to the counter zero position.
Automatic record/playback test
1. Press the [REC START/REC PAUSE] button.
2. The message “MD” is displayed and AUX input is selected.
3. The tape is rewound to the counter zero position and record-
ing is started automatically.
4. When the  x  button  is pressed, the tape is rewound to the
recording stated point and the set starts playback.
5. To exit from this mode, press the "/1 button or disconnect the
power cord.
SECTION 4
TEST MODE
15
HCD-GP6V
SECTION 5
MECHANICAL ADJUSTMENTS
3.04 – 6.96 mN • m
(31 to 71 g • cm)
(0.43 – 0.98 oz • inch)
0.20 – 0.58 mN • m
(2 to 6 g • cm)
(0.02 – 0.08 oz • inch)
3.04 – 6.96 mN • m
(31 to 71 g • cm)
(0.43 – 0.98 oz • inch)
0.20 – 0.58 mN • m
(2 to 6 g • cm)
(0.02 – 0.08 oz • inch)
6.97 – 14.02 mN • m
(71 to 143 g • cm)
(0.98 – 1.99 oz • inch)
9.8 mN • m or more
(100 g • cm or more)
(1.4 oz • inch or more)
9.8 mN • m or more
(100 g • cm or more)
(1.4 oz • inch or more)
CQ-102C
CQ-102C
CQ-102RC
CQ-102RC
CQ-201B
CQ-403A
CQ-403R
Precaution
1.
Clean the following parts with a denatured alcohol-moistened
swab:
record/playback heads
pinch rollers
erase head
rubber belts
capstan
idlers
2.
Demagnetize the record/playback head with a head demag-
netizer.
3.
Do not use a magnetized screwdriver for the adjustments.
4.
After the adjustments, apply suitable locking compound to the
parts adjusted.
5.
The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
Torque Measurement
Mode
FWD
FWD
back tension
REV
REV
back tension
FF/REW
FWD tension
REV tension
Torque meter
Meter reading
16
HCD-GP6V
SECTION 6
ELECTRICAL ADJUSTMENTS
[Record/Playback Head Azimuth Adjustment]
Procedure:
1.
Mode : Playback
2.
Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1 dB of peak.
test tape
P-4-A100
(10kHz, –10dB)
MAIN board
J203
speaker terminal
level meter
set
+
L-CH
peak
R-CH
peak
screw
position
output
level
within
1 dB
L-CH
peak
R-CH
peak
screw
position
within 1dB
Signal
Used for
Tape
P-4-A100
WS-48B
10 kHz, –10 dB
3 kHz, 0 dB
Azimuth Adjustment
Tape Speed Adjustment
 DECK SECTION
 0 dB=0.775V
1.
Demagnetize the record/playback head with a head demagnetizer.
2.
Do not use a magnetized screwdriver for the adjustments.
3.
After the adjustments, apply suitable locking compound to the
parts adjusted.
4.
The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
5.
The adjustments should be performed in the order given in this
service manual. (As a general rule, playback circuit adjustment
should be completed before performing recording circuit
adjustment.)
6.
The adjustments should be performed for both L-CH and R-
CH.
7.
Switches and controls should be set as follows unless otherwise
specified.
4.
After the adjustments, apply suitable locking compound to the
parts adjusted.
Adjustment Location: Record/Playback/Erase Head
[Tape Speed Check]
Procedure:
1.
Turn the power on.
2.
Insert the WS-48B into deck.
3.
Press the  Y  button of deck.
4.
Check the reading of frequency counter becomes 3000 ± 90 Hz.
Sample Value of Wow and flutter
W.RMS (JIS) less than 0.3%
(test tape: WS-48B)
3.
Mode: Playback
test tape
P-4-A100
(10kHz, –10dB)
oscilloscope
set
Waveform of oscilloscope
in phase
45
°
90
°
135
°
180
°
good
wrong
MAIN board
J203
speaker terminal
L
R
Page of 57
Display