9
HCD-EH10
SECTION  4
TEST  MODE
COLD  RESET
*
The cold reset clears all data including preset data stored in
the RAM to initial conditions. Execute this mode when
returning the set to the customer.
Procedure:
1. Press the
I/
1
button to turn the power on.
2. While pressing the
x
button, press the
I/
1
and  [DSGX]
buttons.
3. The message “RESET” is displayed and the set is reset.
PANEL  TEST
*
All segments of liquid crystal display are tested, and the version
and released date of the micro computer are displayed.
Procedure:
1. Press the
I/
1
button to turn the power on.
2. While pressing the [DSGX] button, press the [DISPLAY] and
x
buttons.
Then all segments of liquid crystal display are turned on.
3. Press the [FUNCTION] button, the version and released date of
the micro computer are displayed.
example of display:
4. Press the [TUNER/BAND]  button, the model name and
distination are displayed.
example of display:
5. To exit from this mode, perform the step 2.
TUNER  STEP  CHANGE-OVER
(Except AEP, East European, Russian, UK models)
*
Either the 9 kHz step or 10 kHz step can be selected for the
AM channel step.
Procedure:
1. Set the FUNCTION to AM, and press the
I
/1
button to turn
the power off.
2. Press the [DISPLAY] button.
3. While pressing the [TUNING +] button, press the
I
/1
button.
4. The message “9K STEP” or “10K STEP” is displayed on the
liquid crystal display, and thus the channel step is changed
over.
0629 V008
Version of micro computer
(In this case, version 008)
released date of micro computer
(In this case, released of June 29)
JE   CE2
distination
(In this case, European model)
model name
(In this case, HCD-LFXX)
CD  POWER  MANEGE
*
This mode is for switch the CD power supply on/off. Even if
this state pulls out AC plug, it is held.
Procedure:
1. Press the
I/
1
button to turn the power on.
2. Set the FUNCTION to CD.
3. Press the
I/
1
button again to turn the power off (standby).
4. Press the [DISPLAY] button.
5. While pressing the  
x
  button, press the
I/
1
button.
6. If turns power on and display “CD POWER”, then display
“ON” or “OFF”.
5  REPEAT  OFF  MODE
*
Number of repeat for CD playback is 5 times when the repeat
mode is “REPEAT”. This mode is used to enables CD to repeat
playback for limitless times.
Procedure:
1. Press the
I/
1
button to turn the power on.
2. Press the [FUNCTION] button to select “CD”.
3. Press three buttons of [DSGX],  
CD
 
u
    and  [DISPLAY]
simultaneously.
4. When the 5 repeat off mode is activated, “NO LIMIT” is
displayed on the liquid crystal display.
10
HCD-EH10
SECTION  5
MECHANICAL  ADJUSTMENTS
SECTION  6
ELECTRICAL  ADJUSTMENTS
Precaution
1. Clean the following parts with a denatured-alcohol-moistened
swab :
record/playback head
pinch roller
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head
demagnetizer. (Do not bring the head magnetizer close to the
erase head.)
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, appiy suitable locking compound to
the parts adjusted.
5. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
Torque Measurement
Mode
Torque Meter
Meter Reading
2.0 – 8.0 mN
m
FWD
CQ-102AS
(20 – 80 g
cm)
(0.28 – 1.12 oz
inch)
FWD
0.15 – 0.6 mN
m
Back Tension
CQ-102C
(1.5 – 6.0 g
cm)
(0.021 – 0.083 oz
inch)
5.0 – 17.7 mN
m
FF
CQ-201AS
(50 – 177 g
cm)
(0.7 – 2.48 oz
inch)
5.0 – 17.7 mN
m
REW
CQ-201B
(50 – 177 g
cm)
(0.7 – 2.48 oz
inch)
Tape Tension  Measurement
Mode
Tension Meter
Meter Reading
FWD
CQ-403A
more than 80 g
(more than 2.82 oz)
TUNER  SECTION
0 dB=1 
µ
V
[AM (MW/LW)]
Setting:
Function : TUNER
BAND button : AM
[FM]
Setting:
Function : RADIO
RADIO BAND button: FM
Repeat the procedures in each adjustment several times, and
the  tracking adjustments should be finally done by the trimmer
capacitors.
Remove FM antenna in FM adjustment.
(
): AEP, East European, Russian, UK models
AM VT VOLTAGE ADJUSTMENT
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L852
530 (531) kHz
1.5 
±
 0.1 V
Confirmation
1710 (1602) kHz
8.0 (7.2) 
±
 0.5 V
(
): AEP, East European, Russian, UK models
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L851
530 (531) kHz
FM VT VOLTAGE ADJUSTMENT
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L805
87.5 MHz
1.75 
±
 0.1 V
Confirmation
108 MHz
6.2 
±
 0.5 V
AM RF signal 
generator
30% amplitude 
modulation by 
400 Hz signal
60 cm
set
loop antenna A
loop antenna B
FM RF signal
generator
1 kHz frequency
deviation by FM 75 kHz
signal
Output level: 
as low as possible
+
level meter
MAIN board
JW148
(GND)
MAIN board
JW403
(TUNER OUT L-ch)
set
MAIN board
CNP802 pin 
2
MAIN board
CNP802 pin 
1
digital voltmeter
JW821 (VT)
JW805 (GND)
10 k
MAIN board
Ver. 1.1
11
HCD-EH10
Adjustment Location:
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L804
98 MHz
FM DETECTOR ADJUSTMENT
Setting:
Function: TUNER
BAND button: FM
1. Tune the set to 98 MHz.
2. Adjust L806 so that modulation distortion may become the
best in the vicinity of the maximum value where the tuner out
level becomes -156Bs or more.
set
MAIN board
JW403
(TUNER OUT L-ch)
MAIN board
JW148 (GND)
Carrier frequency : 98 MHz
Modulation
: deviation by
FM 75 kHZ
Output level
: 60 dB
FM RF Signal 
generator
L851
AM Tracking
Adjustment
L805
FM VT
Voltage
Adjustment
L804
FM Tracking
Adjustment
L806
FM Detector
Adjustment
L852
AM VT
Voltage
Adjustment
– MAIN Board (Component Side) –
JW403
(TUNER OUT L-ch)
JW402
(TUNER OUT R-ch)
JW148
(GND)
JW821
(VT)
CNP802
JW805
(GND)
– MAIN Board (Conductor Side) –
3
1
12
HCD-EH10
0 dB=0.775 V
DECK  SECTION
1. Demagnetize the record/playback head with a head
demagnetizer.
2. Do not use a magnetized screwdriver for the adjustments.
Test Tape
Tape
Signal
Used for
P-4-A063
6.3 kHz, -10 dB
Azimuth Adjustment
RECORD/PLAYBACK  HEAD  AZIMUTH  ADJUSTMENT
Note:
Remove the sheet (azimuth) before this adjustment.
After the end of adjustment, try to paste sheet (azimuth) peeled off
to be the same position.
Adjust the tape mechanism deck detaching it from the set when there
is no hole for the azimuth adjustment in the set.
Procedure:
1. Mode:  Playback
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
3. Mode:  Playback
4. After the adjustments, apply suitable locking compound to
the pats adjusted.
Adjustment Location: Record/Playback/Erase Head
– When there is a hole for the azimuth adjustment –
– When there is no hole for the azimuth adjustment –
set
test tape
P-4-A063
(6.3 kHz, –10 dB)
oscilloscope
V
H
waveform of oscilloscope
in phase 45
°
90
°
135
°
180
°
good
wrong
MAIN board
PHONES jack
(J102)
Screw
position
L-CH
peak
within
1dB
Output
level
L-CH
peak
R-CH
peak
within
1dB
Screw
position
R-CH
peak
set
MAIN board
PHONES jack
(J102)
+
level meter
test tape
P-4-A063
(6.3 kHz, –10 dB)
mechanical deck
(H-21SB)
Page of 46