– 9 –
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw so
that outputs match within 1 dB of peak.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
Adjustment Location :
Tape Speed Adjustment
Procedure :
Mode : Playback
3. Mode : Playback
1. Insert the WS-48B into the deck, and playback.
2. Adjust the VR770/RELAY board so that the frequency counter
reading becomes 3000 ± 90 Hz.
Adjustment Location : RELAY board
Sample Value of Wow and flutter
W.RMS (JIS) less than 0.3%
(test tape: WS-48B)
Playback Level Adjustment
Procedure :
Mode : Playback
oscilloscope
MD OUT (JK301)
set
MD OUT (JK301)
test tape
P-4-A100
(10kHz, –10dB)
L
R
Waveform of oscilloscope
good
wrong
in phase
45 
°
90 
°
135 
°
180 
°
L-CH
peak
R-CH
peak
screw
position
output
level
within
1dB
L-CH
peak
R-CH
peak
screw
position
within 1dB
+
MD OUT (JK301)
set
frequency counter
test tape
WS-48B
(3kHz, 0dB)
 FWD side
REV side
Adjustment screw
level meter
MD OUT (JK301)
set
test tape
P-4-L300
(315Hz, 0dB)
Deck is VR703 (L-CH) and VR704 (R-CH)
so that adjustment within the following adjustment level.
Adjustment level :
Playback level: 301.5 to 338.3 mV (–8.2 to –7.2 dB) level dif-
ference between the channels: within ±0.5 dB
Adjustment Location : TAPE PREAMP board
– 10 –
2. Mode : Playback
2. Mode: Playback
Confirm playback the signal recorded in step 1 become adjustment
level as follows.
If these levels do not adjustment level, adjustment the VR701 (L-
CH) and VR702 (R-CH) on the TAPE PREAMP board to repeat
steps 1 and 2.
Adjustment level : Playback output of 10kHz level diffrence
against 315Hz reference should be ±0.5 dB.
Adjustment Location : TAPE PREAMP board
Record Level Adjustment
Procedure :
1. Mode: Record
Confirm playback the signal recorded in step 1 become adjustment
level as follows.
If these levels do not adjustment level, adjustment the VR705 (L-
CH) and VR706 (R-CH) on the TAPE PREAMP board to repeat
steps 1 and 2.
Adjustment level :
Playback level : 47.2 to 53.0 mV (–24.3 to –23.3 dB)
Adjustment Location : TAPE PREAMP board
Adjustment Location
[RELAY BOARD] (Component Side)
Record Bias Adjustment
Procedure :
1. Mode : Record
level meter
MD OUT (JK301)
set
recorded
position
AF OSC
attenuator
600
set
MD IN (JK301)
1) 315Hz
2) 10kHz
blank tape
CS-123
50 mV (–23.8 dB)
}
AF OSC
attenuator
600
set
MD IN (JK301)
315Hz 50 mV (–23.8 dB)
blank tape
CS-123
VR770
level meter
MD OUT (JK301)
set
recorded
position
VR704
VR703
VR706
VR705
VR701
VR702
IC703
1
21
22
42
[TAPE PREAMP BOARD] (Component Side)
– 11 –
Procedure:
1. Connect oscilloscope to test point TP (RF).
2. Turned Power switch on.
3. Put disc (YEDS-18) in and playback.
4. Adjust RV101 so that the waveform is clear.
(Clear RF signal waveform means that the shape “
” can be
clearly distinguished at the center of the waveform.)
5. After adjustment, check the RF signal level.
• RF signal
VOLT/DIV: 200 mV
TIME/DIV: 500 nS
S Curve Check
Procedure :
1. Connect oscilloscope to test point TP (FEO).
2. Connect between test point TP (FOK) and Ground by lead wire.
3. Turn Power switch on.
4. Put disc (YEDS-18) in and turned Power switch on again and
actuate the focus search. (actuate the focus search when disc
table is moving in and out.)
5. Check the oscilloscope waveform (S-curve) is symmetrical be-
tween A and B. And confirm peak to peak level within 2.4 ± 0.7
Vp-p.
S-curve waveform
6. After check, remove the lead wire connected in step 2.
Note:
 • Try to measure several times to make sure than the ratio of
A : B or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the bright-
ness to obtain best waveform.
RF Level Check
Procedure :
1. Connect oscilloscope to test point TP (RF) on BD board.
2. Turned Power switch on.
3. Put disc (YEDS-18) in and playback.
4. Confirm that oscilloscope waveform is clear and check RF sig-
nal level is correct or not.
Note:
Clear RF signal waveform means that the shape “
” can be
clearly distinguished at the center of the waveform.
RF signal waveform
CD SECTION
Note:
1. CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.
2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M
 impedance.
4. Clean the object lens by an applicator with lens cleaning liquid
when the signal level is low than specified value with the fol-
lowing checks.
5. Adjust the focus bias adjustment when optical block is replaced.
Focus Bias Adjustment
+
oscilloscope
 BD board
TP (RF)
TP (VC)
level : 1.3 
±
 0.3 Vp-p
+
oscilloscope
 BD board
TP (FEO)
TP (VC)
symmetry
A
B
within 2.4 
±
 0.7 Vp-p
+
oscilloscope
 BD board
TP (RF)
TP (VC)
level : 1.3 
±
 0.3 Vp-p
VOLT/DIV : 200 mV
TIME/DIV : 500 nS
– 12 –
Procedure :
1. Connect oscilloscpe to test point TP (TE) on BD board.
2. Turn Power switch on.
3. Put disc (YEDS-18) in to play the number five track.
4. Press the “
P (Pause)” button. (Becomes the 1 track jump mode)
5. Confirm that the oscilloscope waveform is symmetrical on the
top and bottom in relation to 0Vdc, and check this level.
1 track jump waveform
E-F Balance (1 Track Jump) Check
(Without remote commander)
Specified level: •                     x 100 = less than ± 7%
• A + B = 300 ± 100 mVp-p
6. Remove the lead wire connected in step 1.
Focus/Tracking Gain Adjustment (RV102, RV103)
This gain has a margin, so even if it is slightly off.
There is no problem.
Therfore, do not perform this adjustment.
Please note that it should be fixed to mechanical center position
when you moved and do not know original position.
A – B
2 (A + B)
Adjustment Location:
[BD BOARD] — Component Side —
+
oscilloscope
 BD board
TP (TE)
TP (VC)
A
B
0V
LEVEL : 300 
±
 100 mVp-p
RF
RV101
RV103
TEO
VC
FEO
RV102
TEI
FEI
FOK
IC101
IC104
GND
PCK
IC102