6. CHECKS PRIOR TO REPAIRS
These checks are performed before replacing parts according to
“approximate specifications” to determine the faulty locations. For
details, refer to “Checks Prior to Parts Replacement and Adjustments
in MD” (see page 25).
6-1. Temperature Compensation Offset Check
When performing adjustments, set the internal temperature and room
temperature to 22 to 28ºC.
Procedure:
1. Press the
“R”
or
“R”
button to display “TEMP
CHECK” (C12).
2. Press the
ENTER/YES “R”
button.
3. “T=@@(##) [OK]” should be displayed. If “T=@@ (##) [NG]”
is displayed, it means that the results are bad.
(@@ indicates the current value set, and ## indicates the value
written in the non-volatile memory.)
6-2. Laser Power Check
Before starting adjustment;
The laser power adjustment value changes depending upon the types
of the optical pick-up (KMS-260B or KMS-260E).
Check the type of the optical pick-up before starting adjustment.
(See the illustrations “The method of ideutifying the optical pick-
up” on page 35
Before checking, check the Iop value of the optical pick-up.
(Refer to 8. Recording and Displaying the Iop Information (see page
34)
Connection:
Procedure:
1. Set the laser power meter on the objective lens of the optical
pick-up. (When it cannot be set properly, press the  m
 “R”
  button
or  M
“R”
  button to move the optical pick-up.)
Connect the digital volt meter to CN105 pin 1  (I+3V) and
CN105 pin 2 (IOP).
2. Then, press the
.
“R”
or
>
“R”
button and display
“LDPWR CHECK” (C13).
3. Press the
ENTER/YES “R”
button once and display “LD
0.9mW$
”. Check that the reading of the laser power meter
becomes specified value.
4. Press the
ENTER/YES “R”
button once more and display “ LD
8.4mW$
”. Check that the reading the laser power meter and
digital volt meter satisfy the specified value.
Specified Value:
Laser power meter reading :
Digital voltmeter reading : Optical pick-up displayed value 
±
 10%
5. Press the
MENU/NO “R”
button and display “LDPWR CHECK”
(C13) and stop the laser emission.
(The
MENU/NO “R”
button is effective at all times to stop the
laser emission.)
Note:
After step 4, each time the
ENTER/YES “R”
button is pressed, the
display will be switched to “LD 0.7W$
”and “LD 6.2mW$
”.
Nothing needs to be performed here.
Checking Location: BD (MD) board (see page 38)
6-3. Iop Compare
The current Iop value at laser power 7 mW output and reference
Iop value (set at shipment) written in the nonvolatile memory are
compared, and the rate of increase/decrease will be displayed in
percentage.
Note:
Perform this function with the optical pick-up set at room tempera-
ture.
Procedure:
1. Press the
.
“R”
or
>
 “R”
button to display “Iop Compare”
(C27).
2. Press the
ENTER/YES “R”
button and start measurements.
3. When measurements complete, the display changes to “
±
 xx%
yy”.
xx is the percentage of increase/decrease, and OK or NG is
displayed at yy to indicate whether the percentage of increase/
decrease is within the allowable range.
4. Press the
MENU/NO “R”
button to end.
5. USING THE CONTINUOUSLY RECORDED DISC
* This disc is used in focus bias adjustment and error rate check.
The following describes how to create a continuous recording
disc.
1. Insert a disc (blank disc) commercially available.
2. Press the
“R”
or
>
  “R”
button and display “CREC  1MODE”
(C35).
3. Press the
ENTER/YES “R”
button again to display “CREC 1
MID”.
Display “CREC 1(0300)” and start to recording.
4. Complete recording within 5 minutes.
5. Press the
MENU/NO “R”
button and stop recording .
6. Press the Z (MD) button and remove the disc.
The above has been how to create a continuous recorded data for
the focus bias adjustment and error rate check.
Note:
 Be careful not to apply vibration during continuous recording.
Optical pick-up
objective lens
laser
power meter
+
BD (MD) board
digital voltmeter
CN105 pin 
1
 (I+3V)
CN105 pin 
2
 (IOP)
KMS260B
20101
H0576
lOP=57.6 mA in this case
lOP (mA) = Digital voltmeter reading (mV)/1 (
)
(Optical pick-up label)
For details of the method for
checking this value, refer to 
“8. Recording and Displaying
the Iop Information”
SPECIFIED VALUE
KMS-260B
KMS-260E
0.85 to 0.91 mW
0.90 to 0.96 mW
KMS-260B
KMS-260E
6.8 to 7.2 mW
7.0 to 7.5 mW
32
HCD-CP500MD
6-4. Auto Check
This test mode performs CREC and CPLAY automatically for
mainly checking the characteristics of the optical pick-up. To perform
this test mode, the laser power must first be checked. Perform Auto
Check after the laser power check and Iop compare.
Procedure:
1. Press the
.
  “R”
or
>
  “R”
button to display “AUTO
CHECK” (C01).
2. Press the
ENTER/YES “R”
button. If “LDPWR 
” is
displayed, it means that the laser power check has not been
performed. In this case, perform the laser power check and Iop
Compare, and then repeat from enter the MD test mode.
3. If a disc is in the mechanical deck, it will be ejected forcibly.
“DISC IN” will be displayed in this case. Load a test disc (MDW-
74/GA-1) which can be recorded.
4. If a disc is loaded at step 3, the check will start automatically.
5. When “XX CHECK” is displayed, the item corresponding to
XX will be performed.
When “06 CHECK” completes, the disc loaded at step 3 will be
ejected. “DISC IN” will be displayed. Load the check disc
(TDYS-1).
6. When the disc is loaded in the step 5, the check will automatically
be resumed from “07 CHECK”.
7. After completing to “0C CHECK” of test item 12, check OK or
NG will be displayed. If all items are OK, “CHK ALL OK” will
be displayed. If any item is NG, it will be displayed as
“NG:xxxx”.
When “CHK ALL OK” is displayed, it means that the optical pick-
up is normal. Check the operations of other parts (spindle motor,
sled motor, etc.).
When displayed as “NG:xxxx”, it means that the optical pick-up is
faulty. In this case, replace the optical pick-up.
6-5. Other Checks
All the following checks are performed by the Auto Check mode.
They therefore need not be performed in normal operation.
6-6. Traverse Check
6-7. Focus Bias Check
6-8. C PLAY Check
6-9. Self-Recording/Playback Check
6-6. Traverse Check
Connection:
Procedure:
1. Connect an oscilloscope to CN105 pin 4 (TE) and CN105 pin
6
 (VC) on the BD (MD) board.
2. Load a disc (any available on the market). (Refer to Note 1)
3. Press the
M
 “R”
button to move the optical pick-up outside
the pit.
4. Press the
“R”
or
>
  “R”
button to display “EF MO
CHECK”(C14).
5. Press the
ENTER/YES “R”
button to display “EFB = 
 MO-
R”.
(Laser power READ power/Focus servo ON/tracking servo OFF/
spindle (S) servo ON)
6. Observe the waveform of the oscilloscope, and check that the
specified value is satisfied. Do not press the
“R”
  or
 >
 “R”
button.
(Read power traverse checking)
Traverse Waveform
7. Press the
ENTER/YES “R”
button to display “EFB = 
 MO-
W”.
8. Observe the waveform of the oscilloscope, and check that the
specified value is satisfied. Do not press the
“R”
  or
 >
 “R”
button.
(Write power traverse checking)
Traverse Waveform
Note 1:
Data will be erased during MO reading if a recorded disc is
used in this adjustment.
Note 2:
If the traverse waveform is not clear, connect the oscilloscope
as shown in the following figure so that it can be seen more
clearly.
+
oscilloscope
(DC range)
10 pF
330 k 
CN105 pin 
4
 (TE)
CN105 pin 
6
 (VC)
BD (MD) board
A
B
VC
Specified value : Below 10% offset value
Offset value (%) =                  X 100  
I
A – B
I
2 (A + B)
A
B
VC
Specified value : Below 10% offset value
Offset value (%) =                  X 100  
I
A – B
I
2 (A + B)
+
oscilloscope
(DC range)
V: 0.1 V/div
H: 10 ms/div
BD (MD) board
CN105 pin 
4
 (TE)
CN105 pin 
6
 (VC)
33
HCD-CP500MD
9. Press the
ENTER/YES “R”
button to display “EFB = 
 MO-
P”.
Then, the optical pick-up moves to the pit area automatically
and servo is imposed.
10. Observe the waveform of the oscilloscope, and check that the
specified value is satisfied. Do not press the
“R”
  or
>
 “R”
button.
Traverse Waveform
11. Press the
ENTER/YES “R”
button to display “EF MO CHECK”
(C14).
The disc stops rotating automatically.
12. Press the  Z  (MD) button and take out the disc.
13. Load the check disc (TDYS-1).
14. Press the
.
  “R”
or
>
  “R”
button and display “EF CD
CHECK” (C15).
15. Press the
ENTER/YES “R”
button to display “EFB = 
 CD”.
Servo is imposed automatically.
16. Observe the waveform of the oscilloscope, and check that the
specified value is satisfied. Do not press the
“R” 
or
 >
 “R”
button.
Traverse Waveform
17. Press the
ENTER/YES “R”
button to display “EF CD CHECK”
(C15).
18. Press the  Z  (MD) button and take out the check disc (TDYS-1).
Checking Location: BD (MD) board (see page 38)
6-7. Focus Bias Check
Change the focus bias and check the focus tolerance amount.
Procedure:
1. Load the test disc (MDW-74/GA-1).
2. Press the
“R”
or
>
 “R”
button to display “CPLAY 1MODE”
(C34).
3. Press the
ENTER/YES “R”
button to display “CPLAY 1MID”.
4. Press the
MENU/NO “R”
button when “C = 
 AD = 
)” is
displayed.
5. Press the
“R”
or
  >
  “R”
button to display “FBIAS
CHECK” (C16).
6. Press the
ENTER/YES “R”
button to display “
/
 c = 
”.
The first four digits indicate the C1 error rate, the two digits
after [/] indicate ADER, and the 2 digits after [c =] indicate the
focus bias value.
Check that the C1 error is below 50 and ADER is below 2.
7. Press the
ENTER/YES “R”
button to display “
/
 b = 
”.
Check that the C1 error is about 200 and ADER is below 2.
8. Press the
ENTER/YES “R”
button to display “
/
 a = 
”.
Check that the C1 error is about 200 and ADER is below 2.
9. Press the
MENU/NO “R”
button, then press the  Z  (MD) button
and take out the test disc.
6-8. C PLAY Check
MO Error Rate Check
Procedure:
1. Load the test disc (MDW-74/GA-1).
2. Press the
“R”
or
  >
 “R”
button to display “CPLAY 1MODE”
(C34).
3. Press the
ENTER/YES “R”
button to display “CPLAY 1MID”.
4. The display changes to “C = 
  AD = 
)”.
5. If the C1 error rate is below 50, check that ADER is 00.
6. Press the
MENU/NO “R”
button to stop playback, then press the
Z  (MD) button and take out the test disc.
CD Error Rate Check
Procedure:
1. Load the check disc (TDYS-1).
2. Press the
“R”
or 
 >
 “R”
button to display “CPLAY 1MODE”
(C34).
3. Press the
ENTER/YES “R”
button to display “CPLAY 1MID”.
4. The display changes to “C = 
 AD = 
)”.
5. Check that the C1 error rate is below 50.
6. Press the
MENU/NO “R”
button to stop playback, then press the
Z  (MD) button and take out the check disc.
6-9. Self-Recording/playback Check
Prepare a continuous recording disc using the unit to be repaired
and check the error rate.
Procedure:
1. Load a recordable disc (blank disc).
2. Press the
“R”
or
  >
  “R”
button to display “CREC
1MODE” (C35).
3. Press the
ENTER/YES “R”
button to display “CREC 1MID”.
4. When recording starts, “REC” and  “CREC 1 (@@@@)”
(@@@@ is the address) are displayed.
5. About 1 minute later, press the
MENU/NO “R”
button to stop
continuous recording.
6. Press the
“R”
or
  >
  “R”
button to display “CPLAY 1
MODE” (C34).
7. Press the
ENTER/YES “R”
button to display “CPLAY 1MID”.
8. “C = 
 AD = 
)” will be displayed.
9. Check that the C1 error becomes below 50 and the AD error
below 2.
10. Press the
MENU/NO “R”
button to stop playback, then press the
Z  (MD) button and take out the disc.
A
B
VC
Specified value : Below 10% offset value
Offset value (%) =                  X 100  
I
A – B
I
2 (A + B)
A
B
VC
Specified value : Below 10% offset value
Offset value (%) =                  X 100  
I
A – B
I
2 (A + B)
34
HCD-CP500MD
7. INITIAL  SETTING  OF  ADJUSTMENT  VALUE
Note:
Mode which sets the adjustment results recorded in the non-volatile
memory to the initial setting value. However the results of the tempera-
ture compensation offset adjustment will not change to the initial setting
value.
If initial setting is performed, perform all adjustments again excluding the
temperature compensation offset adjustment.
For details of the initial setting, refer to “4. Precautions for Adjustments”
(See page 39) and execute the initial setting before the adjustment as re-
quired.
Procedure:
1. Press the
“R”
or
>
 “R”
button to display “ADJ CLEAR”
(C28).
2. Press the
ENTER/YES “R”
button. “Complete!” will be
displayed momentarily and initial setting will be executed, after
which “ADJ CLEAR” (C28) will be displayed.
8. RECORDING  AND  DISPLAYING  THE  IOP
INFORMATION
The IOP data can be recorded in the non-volatile memory. The IOP
value on the optical pick-up label and the IOP value after the
adjustment will be recorded. Recording these data eliminates the
need to read the label on the optical pick-up.
Recording Procedure:
1. Press the
“R”
or
  >
 “R”
button to display “Iop Write”
(C05), and press the
ENTER/YES “R”
button.
2. The display becomes “Ref=@@@.@” (@ is an arbitrary
number) and the numbers which can be changed will blink.
3. Input the IOP value on the optical pick-up label.
To select the number : Press the
“R”
or
 >
 “R”
button.
To select the digit : Press the 
[REC MODE]
 button.
4. When the
ENTER/YES “R”
button is pressed, the display
becomes “Measu=@@@.@” (@ is an arbitrary number).
5. As the adjustment results are recorded for the step 4 value. Leave
it as it is and press the
ENTER/YES “R”
button.
6. “Complete!” will be displayed momentarily. The value will be
recorded in the non-volatile memory and the display will become
“Iop Write” (C05).
Display Procedure:
1. Press the
“R”
or 
 >
 “R”
button to display “IopRead”(C26).
2. “@@.@/##.#” is displayed and the recorded contents are
displayed.
@@.@ indicates the IOP value on the optical pick-up label.
##.# indicates the IOP value after adjustment
3. To end, press the
MENU/NO “R”
button to display “Iop Read”
(C26).
9. TEMPERATURE COMPENSATION OFFSET
ADJUSTMENT
Save the temperature data at that time in the non-volatile memory
as 25 ˚C reference data.
Note:
1. Usually, do not perform this adjustment.
2. Perform this adjustment in an ambient temperature of 22 ˚C to 28 ˚C.
Perform it immediately after the power is turned on when the internal
temperature of the unit is the same as the ambient temperature of 22 ˚C
to 28 ˚C.
3. When D101 has been replaced, perform this adjustment after the tem-
perature of this part has become the ambient temperature.
Procedure:
1. Press the
“R”
or
  >
  “R”
button to display “TEMP
ADJUST” (C03).
2. Press the
ENTER/YES “R”
button to select the “TEMP
ADJUST” mode.
3. “TEMP = 
 [OK]” and the current temperature data will be
displayed.
4. To save the data, press the
ENTER/YES “R”
button.
When not saving the data, press the
MENU/NO “R”
button.
5. When the
ENTER/YES “R”
button is pressed, “TEMP = 
SAVE” will be displayed and turned back to “TEMP ADJUST”
(C03) display then. When the
MENU/NO “R”
button is pressed,
“TEMP ADJUST” (C03) will be displayed immediately.
Specified Value:
The “TEMP =  
” should be within “E0 - EF”, “F0 - FF”, “00 -
0F”,  “10 - 1F” and “20 - 2F”.
10.LASER POWER ADJUSTMENT
Before starting adjustment;
The laser power adjustment value changes depending upon the types
of the optical pick-up (KMS-260B or KMS-260E).
Check the type of the optical pick-up before starting adjustment.
(See the illustrations “The method of identifying the optical pick-
up on page 35.)
Check the IOP value of the optical pick-up before adjustments.
(Refer to 8. Recording and Displaying the Iop Information)
Connection:
Procedure:
1. Insert the laser power meter probe into the disk insertion slot
and set it on top of the objective lens of the optical pick-up.
(When it cannot be set properly, press the
m
  “R”
  button
or
M
 “R”
button to move the optical pick-up)
Connect the digital voltmeter to CN105 pin 1  (I+3V) and
CN105pin 2 (IOP) on the BD (MD) board.
2. Press the
“R”
or
  >
  “R”
button to display “LDPWR
ADJUST” (C04).
(Laser power : For adjustment)
3. Press the
ENTER/YES “R”
button once to display “LD 0.9 mW
”.
4. Press the
“R”
or 
  >
  “R”
button until the laser power
meter reading matches with the specified value as described in
the following table.
Press the
ENTER/YES “R”
button after setting the range knob
of the laser power meter, and save the adjustment results. (“LD
SAVE $ 
” will be displayed for a moment)
5. Then “LD 7.0 mW $ 
” will be displayed.
Optical pick-up
objective lens
laser
power meter
+
BD (MD) board
digital voltmeter
CN105 pin 
1
 (I+3V)
CN105 pin 
2
 (IOP)
SPECIFIED VALUE
KMS-260B
KMS-260E
0.85 to 0.91 mW
0.90 to 0.96 mW