25
HCD-CP500MD
CD  SECITON
[CD SERVO Test Mode]
• Use this mode when checking CD servo.
Procedure:
1.
Press  ?/1  button to turn the set ON.
2.
Select the function “CD”.
3.
Press three buttons  X  (TAPE),  
REC MODE
  and  Z  (CD) simultaneously.
4.
Press the appropriate button for the following tests.
Button
Function
Button
Function
Z(CD)
TEST 1
PLAY MODE DIRECTION
TEST 6
x(CD)
TEST 2
u(CD)
TEST 7
>
TEST 3
x(MD)
TEST 8
.
TEST 4
x(TAPE)
TEST 9
REPEAT/STEREO/MONO
TEST 5
11. WHEN MEMORY NG IS DISPLAYED
If the nonvolatile memory data is abnormal, “E001 MEMORY NG” will be displayed so that the MD deck does not continue operations. In
this case, set the test mode promptly and perform the following procedure.
Procedure:
1. Enter the MD test mode.
2. Normally a message for selecting the test mode will be displayed. However if the nonvolatile memory is abnormal, the following will be
displayed “INIT EEP?”.
3. Press the
x
(MD) and Z (MD) buttons simultaneously.
4. Press the
“R”
or
 >
 “R”
button to display “MDM-7B”.
5. Press the
REC MODE
button. If the nonvolatile memory is successfully overwritten, the normal MD test mode will be set and a message
to select the MD test mode will be displayed.
12. CHECKS PRIOR TO PARTS REPLACEMENT AND ADJUSTMENTS IN MD
Before performing repairs, perform the following checks to determine the faulty locations up to a certain extent.
Details of the procedures are described in “Section 6 Electrical Adjustments”.
• 0.9 mW power
Specified value : figure1
• 7.0 mW power
Specified value : figure2
Iop (at 7.0mW)
• Labeled on the optical pick-up
Iop value 
±
 10mA
• Unsatisfactory if displayed as “NG : XXXX”NG
(XXXX are arbitrary numbers)
• Unsatisfactory if displayed as “T=@@ (##) [NG]”
NG
(@@, ## are both arbitrary numbers)
Laser power check
(6-2 : See page 31)
Auto check
(6-4 : See page 32)
Temperature
compensation
offset check
Criteria for Determination
(Unsatisfactory if specified value is not satisfied)
• Clean the optical pick-up
• Adjust again
• Replace the optical pick-up
• Replace the optical pick-up
• Replace the optical pick-up
• Check for disconnection of the circuits around
D101 (BD board)
• Check the signals around IC101, IC151, CN102,
CN103 (BD board)
Measure if unsatisfactory
Note:
The criteria for determination above is intended merely to determine if satisfactory or not, and does not serve as the specified value for adjustments.
When performing adjustments, use the specified values for adjustments.
5.
To exit from this mode, turn off the set.
Figure1:
SPECIFIED VALUE
KMS-260B
KMS-260E
0.85 to 0.91 mW
0.90 to 0.96 mW
Figure2:
SPECIFIED VALUE
KMS-260B
KMS-260E
6.8 to 7.2 mW
7.0 to 7.5 mW
(6-1 : See page 31)
26
HCD-CP500MD
Precaution
1.
Clean the following parts with a denatured alcohol-moistened
swab:
record/playback heads
pinch rollers
erase head
rubber belts
capstan
idlers
2.
Demagnetize the record/playback head with a head
demagnetizer.
3.
Do not use a magnetized screwdriver for the adjustments.
4.
The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
Torque Measurement
Note:
 Standard Volume Point is +10 dBs at SPEAKER Output Level (6
load resistance) during playbacking P-4-L300 Test Tape.
(DSG OFF, TREBLE/BASS CENTER)
Record/Playback Head Azimuth Adjustment
Procedure:
1.
Mode : Playback
Tape
P-4-A100
WS-48B
P-4-L300
10 kHz, –10 dB
3 kHz, 0 dB
315 Hz, 0 dB
Azimuth Adjustment
Tape Speed Adjustment
Level Adjustment
2.
Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1 dB of peak.
L-CH
peak
R-CH
peak
screw
position
output
level
within
1 dB
L-CH
peak
R-CH
peak
screw
position
within 1dB
3.04 – 6.96 N • m
(31 to 71 g • cm)
(0.43 – 0.98 oz • inch)
0.20 – 0.58 N • m
(2 to 6 g • cm)
(0.02 – 0.08 oz • inch)
3.04 – 6.96 N • m
(31 to 71 g • cm)
(0.43 – 0.98 oz • inch)
0.20 – 0.58 N • m
(2 to 6 g • cm)
(0.02 – 0.08 oz • inch)
6.97 – 14.02 N • m
(71 to 143 g • cm)
(0.98 – 1.99 oz • inch)
0.98 N • m or more
(100 g or more)
(3.53 oz or more)
0.98 N • m or more
(100 g or more)
(3.53 oz or more)
CQ-102C
CQ-102C
CQ-102RC
CQ-102RC
CQ-201B
CQ-403A
CQ-403R
Mode
FWD
FWD
back tension
REV
REV
back tension
FF/REW
FWD tension
REV tension
Torque meter
Meter reading
Signal
Used for
  DECK SECTION
0 dB=0.775V
1.
Demagnetize the record/playback head with a head demagnetizer.
2.
Do not use a magnetized screwdriver for the adjustments.
3.
After the adjustments, apply suitable locking compound to the
parts adjusted.
4.
The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
5.
The adjustments should be performed in the order given in this
service manual. (As a general rule, playback circuit adjustment
should be completed before performing recording circuit
adjustment.)
6.
The adjustments should be performed for both L-CH and R-
CH.
7.
Switches and controls should be set as follows unless otherwise
specified.
SECTION 5
MECHANICAL ADJUSTMENTS
SECTION 6
ELECTRICAL ADJUSTMENTS
test tape
P-4-A100
(10kHz, –10dB)
SJ301
 SPEAKER
Output Terminal
level meter
set
+
27
HCD-CP500MD
4.
After the adjustments, apply suitable locking compound to the
parts adjusted.
Adjustment Location:
3.
Mode: Playback
test tape
P-4-A100
(10kHz, –10dB)
oscilloscope
set
Waveform of oscilloscope
in phase
45
°
90
°
135
°
180
°
good
wrong
GND
R-ch
L
R
SJ301
 SPEAKER
Output Terminal
Sample Value of Wow and flutter
W.RMS (JIS) less than 0.35%
(test tape: WS-48B)
Record Level Check
Procedure:
1.
Press  FUNCTION  button to select ANALOG IN. (This step
is not necessary if the above test mode has already been set.)
2.
Insert a tape into deck, press the  z REC  (TAPE) button, and
then press the  X  (TAPE) button to start recording.
3.
Mode: Record
Tape Speed Check
Procedure:
1.
MODE : Playback.
test tape
WS-48B
(3kHz, 0dB)
SJ301
 SPEAKER
Output Terminal
frequency
counter
set
2.
Insert the WS-48B into deck.
3.
Press the  Y  button of deck.
4.
Check the reading of frequency counter becomes 3000 
±
 90
Hz.
(Top view)
Adjustment point
4.
Mode: Playback
5.
The playback output  level should be –4.5 
±
3 dB (60 Hz),
±
3 dB (8 kHz) and –3 
±
3 dB (10 kHz).
AF OSC
ANALOG IN
1) 60 Hz
2) 5 kHz
3) 10 kHz
blank tape
CS-123
set
attenuator
600 
109 mV (–17 dB)
recorded
position
level meter
set
SJ301
 SPEAKER
28
HCD-CP500MD
CD SECTION
Note :
1. CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.
2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M
 impedance.
4. Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the
following checks.
RF Level Check
Procedure :
1. Connect oscilloscope to TP (RFAC) and TP (DVC 1.65V).
2. Turned Power switch on.
3. Load a disc (YEDS-18) and playback the number five track.
4. Confirm that oscilloscope waveform is clear and check RF signal
level is correct or not.
Note:
Clear RF signal waveform means that the shape “
” can be
clearly distinguished at the center of the waveform.
E-F Balance (1 Track jump) Check
Procedure:
1.
Connect oscilloscope to TP (TE) and TP (DVC 1.65V).
2.
Turned Power switch on.
3.
Load a disc (YEDS-18) and playback the number five track.
4.
Press the  u  button. (Becomes the 1track jump mode.)
5.
Confirm that the level B and A (DC voltage) on the oscilloscope
waveform.
Specification level:      
x
 100=less than 
±
22%
TP(RFAC)
TP(DVC 1.65V)
CD BOARD
oscilloscope
VOLT/DIV : 200mV
TIME/DIV : 500ns
level : 1.1 
±
 0.3Vp-p 
CD BOARD
Oscilloscope
TP (TE)
TP (DVC 1.65V)
0V
Center of
waveform
B
Symmetry
A (DC voltage)
level=1.3 
±
0.6Vp-p
A
B
RF PLL Free-run Frequency
Procedure :
1.
Connect frequency counter to TP (XPCK) with lead wire.
2.
Turned Power switch on.
3.
Put the disc (YEDS-18) in to play the number five track.
Confirm that reading on frequency counter is 4.3218MHz.
Test Point Location :
[CD BOARD] — SIDE B —
+
frequency counter
CD BOARD
TP (XPCK)
TP
(DVC 1.65V)
TP
(TE)
IC101
IC103
TP 
(XPCK)
TP 
(RFAC)