2. PRECAUTIONS FOR CHECKING LASER DIODE
EMISSION
To check the emission of the laser diode during adjustments, never
view directly from the top as this may lose your eye-sight.
3. PRECAUTIONS FOR USE OF OPTICAL PICK-UP
(KMS-260B/260E)
As the laser diode in the optical pick-up is easily damaged by static
electricity, solder the laser tap of the flexible board when handling
it.
Before disconnecting the connector, solder first. Before connecting
the connector, be careful not to remove the solder. Also take adequate
measures to prevent damage by static electricity. Handle the flexible
board with care as it breaks easily.
Optical pick-up flexible board
pick-up
flexible board
laser tap
4. PRECAUTIONS FOR ADJUSTMENTS
1. When replacing the following parts, perform the adjustments
and checks with 
 in the order shown in the following table.
2. Set the MD test mode when performing adjustments.
After completing the adjustments, exit the MD test mode.
Perform the adjustments and checks in “Group Service” of the
MD test mode.
3. Perform the adjustments to be needed in the order shown.
4. Use the following tools and measuring devices.
• Check Disc (TDYS-1) (Part No. : 4-963-646-01)
• Test Disk (MDW-74/GA-1) (Part No. : 4-229-747-01)
• Laser power meter LPM-8001 (Part No. : J-2501-046-A)
or MD Laser power meter 8010S (Part No. : J-2501-145-A)*
1
• Oscilloscope (Measure after performing CAL of prove.)
• Digital voltmeter
• Thermometer
• Jig for checking BD (MD) board waveform
(Part No. : J-2501-196-A)
5. When observing several signals on the oscilloscope, etc.,
make sure that VC and ground do not connect inside the
oscilloscope.
(VC and ground will become short-circuited.)
6. Using the above jig enables the waveform to be checked without
the need to solder.
(Refer to Servicing Notes on page 6.)
7. As the disc used will affect the adjustment results, make sure
that no dusts nor fingerprints are attached to it.
*
1
Laser power meter
When performing laser power checks and adjustment (electrical
adjustment), use of the new MD laser power meter 8010S (Part
No. J-2501-145-A) instead of the conventional laser power
meter is convenient.
It sharply reduces the time and trouble to set the laser power
meter sensor onto the objective lens of optical pick-up.
7.
Initial setting of adjustment value
8.
Recording of Iop information
9.
Temperature compensation
offset adjustment
10. Laser power adjustment
11. Iop NV Save
12. Traverse adjustment
13. Focus bias adjustment
16. Auto gain control output level
adjustment
6-4. AUTO CHECK
Optical
Pick-up
IC101
IC102
IC151
IC190
IC195
D101
Parts to be replaced
Adjustment
37
HCD-C5
5. USING THE CONTINUOUSLY RECORDED DISC
* This disc is used in focus bias adjustment and error rate check.
The following describes how to create a continuous recording
disc.
1. Insert a disc (blank disc) commercially available.
2. Press the  . 
“R”
  or  >
 “R”
   button and display “CREC 1MODE”
(C35).
3. Press the  
ENTER/YES “R”  
button again to display “CREC 1
MID”.
Display “CREC 1(0300)” and start to recording.
4. Complete recording within 5 minutes.
5. Press the  
MENU/NO “R”
  button and stop recording .
6. Press the  
MD 
Z  button and remove the disc.
The above has been how to create a continuous recorded data for
the focus bias adjustment and error rate check.
Note:
 Be careful not to apply vibration during continuous recording.
6. CHECKS PRIOR TO REPAIRS
These checks are performed before replacing parts according to
“approximate specifications” to determine the faulty locations. For
details, refer to “Checks Prior to Parts Replacement and Adjustments
in MD” (see page 30).
6-1. Temperature Compensation Offset Check
When performing adjustments, set the internal temperature and room
temperature to 22 to 28ºC.
Procedure:
1. Press the  
“R”
  or  
“R”
  button to display “TEMP
CHECK” (C12).
2. Press the  
ENTER/YES “R”
  
button.
3. “T=@@(##) [OK]” should be displayed. If “T=@@ (##) [NG]”
is displayed, it means that the results are bad.
(@@ indicates the current value set, and ## indicates the value
written in the non-volatile memory.)
6-2. Laser Power Check
Before starting adjustment;
The laser power adjustment value changes depending upon the types
of the optical pick-up (KMS-260B or KMS-260E).
Check the type of the optical pick-up before starting adjustment.
(See the illustrations “The method of identifying the optical pick-
up” on page 41)
Before checking, check the Iop value of the optical pick-up.
(Refer to 8. Recording and Displaying the Iop Information (see page
40))
Connection:
Procedure:
1. Set the laser power meter on the objective lens of the optical
pick-up. (When it cannot be set properly, press the  m
 “R”
  button
or  M 
“R”
  button to move the optical pick-up.)
Connect the digital volt meter to CN105 pin 1 (I+3V) and
CN105 pin 2 (IOP).
2. Then, press the  
“R”
  or  
“R”
  button and display
“LDPWR CHECK” (C13).
3. Press the  
ENTER/YES “R”
  
button once and display “LD 0.9mW$
  ”. Check that the reading of the laser power meter becomes
specified value.
4. Press the
ENTER/YES “R”
button once more and display “ LD
7.0mW$    ”. Check that the reading the laser power meter and
digital volt meter satisfy the specified value.
Specified Value:
Laser power meter reading :
Digital voltmeter reading : Optical pick-up displayed value 
±
 10%
5. Press the  
MENU/NO  “R”
  button and display “LDPWR
CHECK” (C13) and stop the laser emission.
(The  
MENU/NO “R”
  button is effective at all times to stop the
laser emission.)
Note:
After step 4, each time the  
ENTER/YES “R”  
button is pressed, the
display will be switched to “LD 0.7W$    ”and “LD 6.2mW$    ”
“LD WP 
 $    ”. Nothing needs to be performed here.
Checking Location: BD (MD) board (see page 44)
6-3. Iop Compare
The current Iop value at laser power 7.0 mW output and reference
Iop value (set at shipment) written in the nonvolatile memory are
compared, and the rate of increase/decrease will be displayed in
percentage.
Note:
Perform this function with the optical pick-up set at room tempera-
ture.
Procedure:
1. Press the  . 
“R”
  or  >
 “R”
  button to display “Iop Compare”
(C27).
2. Press the  
ENTER/YES “R”  
button and start measurements.
3. When measurements complete, the display changes to “
±
 xx%
yy”.
xx is the percentage of increase/decrease, and OK or NG is
displayed at yy to indicate whether the percentage of increase/
decrease is within the allowable range.
4. Press the  
MENU/NO “R”
  button to end.
Optical pick-up
objective lens
laser
power meter
+
BD (MD) board
digital voltmeter
CN105 pin 
1
 (I+3V)
CN105 pin 
2
 (IOP)
KMS260B
20101
H0576
lOP = 57.6 mA in this case
lOP (mA) = Digital voltmeter reading (mV)/1 (
)
(Optical pick-up label)
For details of the method for
checking this value, refer to 
“8. Recording and Displaying
the Iop Information”
SPECIFIED VALUE
KMS-260B
KMS-260E
0.85 to 0.91 mW
0.90 to 0.96 mW
KMS-260B
KMS-260E
7.0 to 0.2 mW
7.25 to 0.25 mW
38
HCD-C5
6-4. Auto Check
This test mode performs CREC and CPLAY automatically for
mainly checking the characteristics of the optical pick-up. To perform
this test mode, the laser power must first be checked. Perform Auto
Check after the laser power check and Iop compare.
Procedure:
1. Press the  
.
 “R”
  or  
>
 “R”
  button to display “AUTO CHECK”
(C01).
2. Press the  
ENTER/YES  “R”
   
button. If “LDPWR        ” is
displayed, it means that the laser power check has not been
performed. In this case, perform the laser power check and Iop
Compare, and then repeat from enter the MD test mode.
3. If a disc is in the mechanical deck, it will be ejected forcibly.
“DISC IN” will be displayed in this case. Load a test disc (MDW-
74/GA-1) which can be recorded.
4. If a disc is loaded at step 3, the check will start automatically.
5. When  “XX CHECK” is displayed, the item corresponding to
XX will be performed.
When “06 CHECK” completes, the disc loaded at step 3 will be
ejected.  “DISC IN” will be displayed. Load the check disc
(TDYS-1).
6. When the disc is loaded in the step 5, the check will automatically
be resumed from “07 CHECK”.
7. After completing to test item 12 (“oC CHECK”), check OK or
NG will be displayed. If all items are OK, “CHK ALL OK” will
be displayed. If any item is NG, it will be displayed as
“NG:xxxx”.
When “CHK ALL OK” is displayed, it means that the optical pick-
up is normal. Check the operations of other parts (spindle motor,
sled motor, etc.).
When displayed as “NG:xxxx”, it means that the optical pick-up is
faulty. In this case, replace the optical pick-up.
6-5. Other Checks
All the following checks are performed by the Auto Check mode.
They therefore need not be performed in normal operation.
6-6. Traverse Check
6-7. Focus Bias Check
6-8. C PLAY Check
6-9. Self-Recording/Playback Check
6-6. Traverse Check
Note 1:
Data will be erased during MO reading if a recorded disc is
used in this adjustment.
Note 2:
If the traverse waveform is not clear, connect the oscilloscope
as shown in the following figure so that it can be seen more
clearly.
Connection:
Procedure:
1. Connect an oscilloscope to CN105 pin 4 (TE) and CN105 pin
6
 (VC) on the BD (MD) board.
2. Load a disc (any available on the market). (Refer to Note 1)
3. Press the
M
 “R”
button to move the optical pick-up outside
the pit.
4. Press the
“R”
or
>
  “R”
button to display “EF MO
CHECK”(C14).
5. Press the
ENTER/YES “R”
button to display “EFB =     MO-
R”. (Laser power READ power/Focus servo ON/tracking servo
OFF/spindle (S) servo ON)
6. Observe the waveform of the oscilloscope, and check that the
specified value is satisfied. Do not press the
“R”
 or
 >
 “R”
button.
(Read power traverse checking)
Traverse Waveform
7. Press the  
ENTER/YES “R”
  
button to display “EFB =     MO-
W”.
8. Observe the waveform of the oscilloscope, and check that the
specified value is satisfied. Do not press the
“R”
 or
 >
 “R”
button. (Write power traverse checking)
Traverse Waveform
+
oscilloscope
(DC range)
10 pF
330 k 
CN105 pin 
4
 (TE)
CN105 pin 
6
 (VC)
BD (MD) board
A
B
VC
Specified value : Below 10% offset value
Offset value (%) =                  X 100  
I
A – B
I
2 (A + B)
A
B
VC
Specified value : Below 10% offset value
Offset value (%) =                  X 100  
I
A – B
I
2 (A + B)
+
oscilloscope
(DC range)
V: 0.1 V/div
H: 10 ms/div
BD (MD) board
CN105 pin 
4
 (TE)
CN105 pin 
6
 (VC)
39
HCD-C5
9. Press the
ENTER/YES “R”
button to display “EFB =     MO-
P”.
Then, the optical pick-up moves to the pit area automatically
and servo is imposed.
10. Observe the waveform of the oscilloscope, and check that the
specified value is satisfied. Do not press the . 
“R”
 or
>
 “R”
button.
Traverse Waveform
11. Press the
ENTER/YES “R”
button to display “EF MO CHECK”
(C14).
The disc stops rotating automatically.
12. Press the  
MD 
Z  button and take out the disc.
13. Load the check disc (TDYS-1).
14. Press the .
 “R”
or >
 “R”
button and display “EF CD
CHECK” (C15).
15. Press the
ENTER/YES “R”
button to display “EFB =      CD”.
Servo is imposed automatically.
16. Observe the waveform of the oscilloscope, and check that the
specified value is satisfied. Do not press the . 
“R” 
or
 >
 “R”
button.
Traverse Waveform
17. Press the
ENTER/YES  “R”
button to display “EF CD
CHECK” (C15).
18. Press the  
MD 
Z  button and take out the check disc (TDYS-1).
Checking Location: BD (MD) board (see page 44)
6-7. Focus Bias Check
Change the focus bias and check the focus tolerance amount.
Procedure:
1. Load the test disc (MDW-74/GA-1).
2. Press the  . 
“R”
  or  >
 “R”
  button to display “CPLAY
1MODE” (C34).
3. Press the
ENTER/YES “R”
button to display “CPLAY 1MID”.
4. Press the
MENU/NO “R”
button when “C =          AD =  
” is displayed.
5. Press the  . 
“R”
  or  >
 “R”
  button to display “FBIAS
CHECK” (C16).
A
B
VC
Specified value : Below 10% offset value
Offset value (%) =                  X 100  
I
A – B
I
2 (A + B)
A
B
VC
Specified value : Below 10% offset value
Offset value (%) =                  X 100  
I
A – B
I
2 (A + B)
6. Press the
ENTER/YES “R”
button to display “        /      c =
   ”.
The first four digits indicate the C1 error rate, the two digits
after [/] indicate ADER, and the 2 digits after [c =] indicate the
focus bias value.
Check that the C1 error is below 20 and ADER is below 2.
7. Press the  
ENTER/YES “R”  
button to display “        /      b =
   ”.
Check that the C1 error is about 100 and ADER is below 2.
8. Press the  
ENTER/YES “R”  
button to display “        /      a =
   ”.
Check that the C1 error is about 100 and ADER is below 2.
9. Press the  
MENU/NO “R”
  button, then press the  
MD 
Z  button
and take out the test disc.
6-8. C PLAY Check
MO Error Rate Check
Procedure:
1. Load the test disc (MDW-74/GA-1).
2. Press the  . 
“R”
  or  >
 “R”
  button to display “CPLAY
1MODE” (C34).
3. Press the  
ENTER/YES “R”  
button to display “CPLAY 1MID”.
4. The display changes to “C =         AD =     ”.
5. If the C1 error rate is below 20, check that ADER is 00.
6. Press the  
MENU/NO “R”
  button to stop playback, then press
the  
MD 
Z  button and take out the test disc.
CD Error Rate Check
Procedure:
1. Load the check disc (TDYS-1).
2. Press the  . 
“R”
  or  >
 “R”
  button to display “CPLAY
1MODE” (C34).
3. Press the  
ENTER/YES “R”  
button to display “CPLAY 1MID”.
4. The display changes to “C =         AD =     )”.
5. Check that the C1 error rate is below 20.
6. Press the  
MENU/NO “R”
  button to stop playback, then press
the   
MD 
Z  button and take out the check disc.
6-9. Self-Recording/playback Check
Prepare a continuous recording disc using the unit to be repaired
and check the error rate.
Procedure:
1. Load a recordable disc (blank disc).
2. Press the  . 
“R”
  or  >
 “R”
  button to display “CREC
1MODE” (C34).
3. Press the  
ENTER/YES “R”  
button to display “CREC 1MID”.
4. When recording starts,  “  
REC
  ” and display “CREC 1 @@@@”
(@@@@ is the address).
5. About 1 minute later, press the  
MENU/NO “R”
  button to stop
continuous recording.
6. Press the  . 
“R”
  or  >
 “R”
  button to display “CPLAY
1 MODE” (C34).
7. Press the
ENTER/YES  “R”
button to display “CPLAY 1
MID”.
8. “C =         AD =     )” will be displayed.
9. Check that the C1 error becomes below 20 and the AD error
below 2.
10. Press the
MENU/NO “R”
button to stop playback, then press
the   
MD 
Z  button and take out the disc.
REC
Page of 97