Sony CHC-P33D / HCD-H33D Service Manual ▷ View online

– 13 –
Record Bias Adjustment
Procedure :
1. Mode : Record
 DECK B
set
MD IN
1) 315 Hz
2) 10 kHz
blank tape
CS-123
600 
attenuator
AF OSC
38.8 mV (–26 dB)
2. Mode : Playback
3. Confirm playback the signal recorded in step 1 become adjust-
ment level as follows.
4. If these levels do not adjustment level, adjustment the RV341
(L-CH) and RV441 (R-CH) to repeat step 1 and 4.
Adjustment level :
Playback output of 315 Hz to playback output of 10 kHz : –0.5 dB
to 0.5 dB. (–1.3 to 1.3 mV)
Adjustment Location : AUDIO board
Record Level Adjustment
Procedure :
1.  Mode : Record
 DECK B
2. Mode : Playback
3. Confirm playback the signal recorded in step become adjust-
ment level as follows.
4. If these levels do not adjustment level, adjust the RV401 (L-
CH) and RV451 (R-CH) to repeat step 1 and 4.
Adjustment Level :
OUTPUT level : –26 dB ± 0.5 dB (36.7 to 41.1 mV)
Adjustment Location : MAIN board
Adjustment Location :
[AUDIO BOARD] – Conductor side –
set
+
recorded
portion
MD OUT
level meter
set
MD IN
315 Hz, 38.8 mV (–26 dB)
blank tape
CS-123
600 
attenuator
AF OSC
set
+
recorded
portion
MD OUT
level meter
RV301: Playback Level (Deck B L-CH)
RV401: Playback Level
(Deck B R-CH)
RV651:Tape Speed
(Normal)
RV652: Tape speed
(HIGH)
RV311: Playback Level
(Deck A L-CH)
RV411: Playback Level
(Deck A R-CH)
RV341: Record Bias (L-CH)
RV441: Record Bias (R-CH)
[MAIN BOARD]  – Component side –
RV401:
Record Level (L-CH)
RV451:
Record Level (R-CH)
– 14 –
Procedure :
1. Tune the set to 98 MHz
2. Adjust RV42 so that the TUNED indicatior goes on.
Adjustment Location : TCB board (see page 15)
SW OSC Voltage Adjustment (E3, EA, MY, SP, HK model)
Setting :
Band : SW
Procedure :
1. Connect digital Voltmeter to diode D1 center lead and ground.
2. Adjust for a following value reading on digital Voltmeter.
Set frequency
Adjustment
Reading on
part
digital voltmeter
SW
5.95 MHz
T2
1.2 Vdc
17.9 MHz
CV2
8.5 Vdc
Adjustment Location : TCB board (see page 15)
SW Tracking Adjustment (E3, EA, MY, SP, HK model)
Setting :
Band : SW
Procedure :
Adjust for maximum reading on level meter.
Set frequency
Adjustment
part
SW
7 MHz
T1
17 MHz
CV1
Repeat the procedures is each adjustment several times, and the
frequency coverage and tracking adjustment should be finally done
by the trimmer capacitors.
Adjustment Location : TCB board (see page 15)
set
AM RF signal
generator
Modulation: 400 Hz
30% modulation
+
level meter
SPEAKER terminal
AM ANTENNA terminal
TUNER SECTION
Precautions in Repairing
Note. 1 
: The adjustment should be performed in the publication.
(MW 
 FM 
 SW)
Note. 2 
: As a front-end (FE1) is difficult to repair if faulty, re-
place it with new one.
Abbreviation
E2
: Tuner sections SW BAND do not exist.
E3
: Turner sections SW BAND exist.
EA : Saudi Arabia
MY : Malaysia
SP
: Singapore
HK : Hong Kong
AM Tuned Level Adjustment
Setting :
Band : MW
Procedure :
1. Set loop antenna A so that the loop antenna B input level be-
comes 55 dBµ/m (0.56 mV/m)
2. Tune the set to 999 kHz (at 9 kHz step) or 1,050 kHz (at 10 kHz
step).
3. Adjust RV41 so that the TUNED indicatior goes on.
Adjustment Location : TCB board (see page 15)
FM Tuned Level Adjustment
Note :
Always make the tuning level adjustment first.
(Since it affects the FM tuning level).
Setting :
Band : FM
AM RF signal
generator
loop antenna A
set
loop antenna B
Carrier frequency
Modulation
: 999 kHz (at 9 kHz step) or
  1,050 kHz (at 10 kHz step)
: 400 Hz 30 % modulation
set
FM ANTENNA terminal (TM1)
FM RF stereo signal
generator
Carrier frequency : 98 MHz
Modulation
: 1 kHz, 75 kHz (100%)
Output level
: 0.018 mV (25 dB 
µ
)
75 
 coaxial
– 15 –
Adjustment Location
[TCB BOARD] – Component side –
CD SECTION
Note :
1. CD Block basically constructed to operate without adjustment.
Therefore, check each item in order given.
2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3. Use the oscilloscope with more than 10M
 impedance.
4. Clean an object lens by an applicatior with neutral detergent
when the signal level is low than specified value with the fol-
lowing checks.
Focus Bias Adjustment
This adjustment is to be done when the optical block is replaced.
Adjustment procedure :
1. Connect oscilloscope to test point TP (VC) and TP (RF) on BD
board.
2. Ground main board IC101 (pin (£) with the lead wire.
3. Turned power switch ON. (Stop mode)
4. Put disc (YEDS-18) in and press the 
( button.
5. Press the 
P button. (Tracking servo ON)
6. Adjust RV101 so that the oscilloscope waveform is as shown in
the figure below (eye pattern).
A good eye pattern means that the diamond shape (≈) in the
center of the waveform can be clearly distinguished.
7. After adjustment, remove the lead wire connecd in step 2.
 
RF signal reference waveform (eye pattern)
When observing the eye pattern, set the oscilloscope for AC
range and raise vertical sensitivity.
Adjustment Location : BD board (see page 16)
S-Curve Check
Procedure :
1. Connect oscilloscope to test point TP (FEO) on BD board.
2. Connect between test point TP (FOK) and TP (GND) by lead
wire.
3. Turned Power switch on.
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
1.3 
±
 0.3 Vp-p
+
BD board
TP (FEO)
TP (VC)
oscilloscope
+
BD board
TP (RF)
TP (VC)
oscilloscope
(DC range)
FE1
D1
CV1: SW Tracking Adjustmnet
T1: SW Tracking Adjustment
RV41:
AM Tuned Level
Adjustment
CV2:
SW OSC voltage
Adjustment
T2:
SW OSC voltage
Adjustment
RV42:
FM Tuned Level
Adjustment
– 16 –
6. After check, remove the lead wire connected in step 2.
Note :
Try to measure several times to make sure that the ratio
of A : B or B : A is more than 10 : 7.
Take sweep time as long as possible and light up the
brightness to obtain best waveform.
Adjustment Location : BD board (see page 16)
RF Level Check
+
BD board
TP (RF)
TP (VC)
oscilloscope
Procedure :
1. Connect oscilloscope to test point TP (RF) on BD board.
2. Turned Power switch on.
3. Put disc (YEDS-18) in and press the 
( button.
4. Confirm that oscilloscope waveform is clear and check RF sig-
nal level is correct or not.
Note :
Clear RF signal waveform means that the shape “≈” can be
clearly distinguished at the center of the waveform.
 
RF signal waveform
Adjustment Location : BD board (see page 16)
E-F Balance Check
+
BD board
TP (TEO)
TP (VC)
oscilloscope
Procedure :
1. Ground MAIN board IC101 (pin (£) with the lead wire.
2. Connect oscilloscope to test point TP (TEO) on BD board.
3. Turned Power switch on.
4. Put disc (YEDS-18) in and press the 
( button.
5. Confirm that the oscilloscope waveform is symmetrical on the
top and bottom in relation to 0 Vdc, and check this level.
specified level :
 —————— 
×
 100 = less than ± 7%
 A+B= 300 ± 100 mVp-p
6. Remove the lead wire connected in step 1.
Focus/Tracking Gain Adjustment (RV102, RV103)
This gain has a margin, so even if it is slightly off. There is no prob-
lem.
Therefore, do not perform, this adjustment.
Please note that it should be fixed to mechanical center position
when you moved and do not know original position.
Adjustment Location :
[BD BOARD] – Side B –
A-B
2 (A + B)
RF
FOK
RV101
IC101
IC102
TE1
FE1
FEO
RV103
TEO
VC
RV102
PCK
GND
IC104
symmetry
within 2.4 ± 0.7 Vp-p
4. Put disc (YEDS-18) in and turned Power switch on again and
actuate the focus search.  (actuate the focus search when disc
table is moving in and out.)
5. Check the oscilloscope waveform (S-curve) is symmetrical be-
tween A and B. And confirm peak to peak level within 2.4 ± 0.7
Vp-p.
 
S-curve waveform
B
A
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
level:
1.3 
±
 0.3Vp-p
level: 300 ± 100 mVp-p
0 V
A
B
 
Traverse waveform
Page of 45