7
CFS-929S
2-7. REC SW BOARD, BELT, MOTOR ASSY (W) (M301)
2-6. JOG, LED1 BOARDS
4
 BVTP 3x10
5
 LED1 board
6
 window (LED)
2
 BVTP 3x10
3
 JOG board
1
 jog dial
1
 PTT 2x6
2
 REC SW board
9
 motor screw
deck A
deck B
5
 PTT 2x5
7
 PTT 2x5
3
 PTT 2x5
0
 motor assy (M301)
6
 bracket
8
 chassis (joint)
4
 sssss
qa
 belt
qs
 belt
8
CFS-929S
SECTION 3
DIAL POINTER SETTING
UP
pointer
knob (TUNING) assy
knob (TUNING) assy
1
 pointer
2
 knob (TUNING) assy
3
 midway gear
midway gear
4
 PTPWH 3x10
4
 TUNER board
8
 F/T board
1
 gear (VC)
2
5
 BVTP 3x10
3
6
 BVTP 3x10
7
 BVTP 3x10
9
 BVTP 3x10
9
CFS-929S
PRECAUTION
1. Clean the following parts with a denatured alcohol-moistened
swab :
record/playback head
pinch roller
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head demagne-
tizer. (Do not bring the head demagnetizer close to the erase
head.)
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
6. Power supply voltage: 12 V dc.
Torque Measurement   DECK A     DECK B
Mode
Torque meter
Meter reading
2.21 to 5.39 mN • m
Forward
CQ-102C
22.5 to 55 g • cm
(0.31 to 0.76 oz • inch)
Forward
0.20 to 0.49 mN • m
back tension
CQ-102C
2 to 5 g • cm
(0.03 to 0.07 oz • inch)
Fast Forward
5.89 to 11.76 mN • m
and
CQ-201B
60 to 120 g • cm
Rewind
(0.83 to 1.67 oz • inch)
Tape Tension Measurement   DECK A     DECK B
Mode
Tension meter
Meter reading
Forward
CQ-403A
more than 150 g
(more than 5.29 oz)
SECTION 5
ELECTRICAL ADJUSTMENTS
SECTION 4
MECHANICAL ADJUSTMENTS
  TAPE SECTION     0 dB = 0.775 V
Standard Output Level
Output terminal
SP OUT
PHONES OUT
load impedance
32 
output signal level
0.775 V (0 dB)
0.25 V (–10 dB)
Test Tape
Tape
Signal
Used for
WS-48A
3 kHz, 0 dB
tape speed adjustment
Tape Speed Adjustment   DECK A     DECK B
Procedure:
• Perform normal speed adjustment before high speed check.
Mode: playback (deck A)
record (deck B)
Deck
Tape
Adjustment
Frequency
speed
point
counter
A
Normal (playback)
RV302
3,000 to 3,030 Hz
A
HI-SPEED DUBBING
(confirmation) 5,300 to 6,300 Hz
(playback)
B
HI-SPEED DUBBING
———
———
(record)
Frequency difference between the beginning and the end of the
tape should be within ± 1.0% (both Normal and Hi-speed).
Adjustment Location: – main board (component side) –
PHONES jack (J301)
set
32 
test tape
WS-48A
(3 kHz, 0 dB)
digital frequency
counter
Adjust RV301 so that reading on digital frequency counter
becomes 3,000 Hz.
Specification Value:
RV302
– MAIN board (component side) –
10
CFS-929S
Adjustment Location: See page 11
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
L9
10.7 MHz
FM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L2
87.35 MHz (EA model)
86.5 MHz (E15, UAE model)
CT2
107.8 MHz (EA model)
109.5 MHz (E15, UAE model)
FM TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
87.35 MHz (EA model)
86.5 MHz (E15, UAE model)
CT1
107.8 MHz (EA model)
109.5 MHz (E15, UAE model)
MW IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
455 kHz
MW FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L4
516 kHz (EA model)
520 kHz (E15, UAE model)
CT4
1,635 kHz (EA model)
1,680 kHz (E15, UAE model)
MW TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
600 kHz
CT3
1,400 kHz
SW1 FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L6
2.2 MHz
CT6
7.3 MHz
SW1 TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L5
2.2 MHz
< confirmation >
7.3 MHz
SW2 FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L8
6.8 MHz
CT8
22.5 MHz
SW2 TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L7
6.8 MHz
< confirmation >
22.5 MHz
  TUNER SECTION     0 dB = 1 µV
Common Setting:
SOUND SELECT control: FLAT
VOLUME control: MAX
MAXI BASS switch: OFF
• FM Section
BAND switch: FM
• MW Section
BAND switch: MW
FINE TUNING (RV2): mechanical center
• SW1/SW2 Section
BAND switch: SW1 or SW2
FINE TUNING (RV2): mechanical center
• Common Connecting Level Meter
telescopic
antenna terminal
0.01
µF
FM RF signal
generator
75kHz frequency deviation
by 1kHz signal
Output level: as low as possible
set
Put the lead-wire
antenna close to
the set.
AM RF signal
generator
400Hz, 30% 
AM modulation
Output level: as low as possible
telescopic
antenna terminal
12pF
AM RF signal
generator
400Hz, 30% 
AM modulation
Output level: as low as possible
set
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
PHONES jack (J301)