11
CFD-V3/V7/V7L
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
 (       ) : V3/V7: AEP, UK, CET, SP,KR
 <     > : V7:Italian
 [       ] : V7L
AM/LW IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T2
455kHz
EXCEPT V7L
AM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L4
520kHz  (   520kHz)  <   516kHz>
CT4
1,780kHz  (1,680kHz)  <1,630kHz>
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
620kHz
CT3
1,400kHz
V7L
LW FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L4
145kHz
CT4, CV2
300kHz
LW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
160kHz
CT3, CV3
260kHz
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
10.7MHz
FM FREQUENCY COVERAGE  ADJUSTMENT
Adjust for a maximum reading on level meter.
L2
86.5MHz (  87.0MHz) <  87.35MHz> [  87.0MHz]
CT2
109.5MHz (108.3MHz) <108.25MHz> [108.3MHz]
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
86.5MHz (  87.0MHz) <  87.35MHz> [  87.0MHz]
CT1
109.5MHz (108.3MHz) <108.25MHz> [108.3MHz]
Adjustment Location : Main board (See page 12)
CD section adjustments are done automatically in this set.
In case of operation check, confirm that focus bias.
Focus Bias Check
1. Connect the oscilloscope between TP (RF) and GND on CD
board.
2. Insert the disc (YEDS-18). (Part No. : 3-702-101-01)
3. Press the 7 button two times (LPC ON).
4. Confirm that the oscilloscope waveform is as shown in the fig-
ure below. (eye pattern)
A good eye pattern means that the diamond shape (
◊) in the
center of the waveform can be clearly distinguished.
RF Signal Reference Waveform (eye pattern)
When observing the eye pattern, set the oscilloscope for AC range
and raise certical sensitivity
RF level
0.7 – 1.0 Vp-p (LPC ON)
1.0 – 1.4 Vp-p (LPC OFF)
VOLT/TV : 200mV
TIME/DIV : 500 nS
CD SECTION
How to put the set into CD Test Mode
1. Set the function switch to power off.
2. Set the function switch to CD.
3. Set Test mode by momentarily shorting both of the IC801 51pin
to GND. (Shorting the terminals momentarily is sufficient).
The set is into CD test mode (
88 is displayed).
4. Turn the power off to release test mode.
S351
R812
R811
R809
R810
-1   -2
R851
C844
C
8
C8
R815
R814
R813
 
C801
R816
R
JC310
C810
JW316
JW317
JW318
320
21
IC801
GND
51pin
TEST mode : momentarily short
[MAIN BOARD] (Conductor side)
C730
R730
R729
C704
C736
C734
R704
R702
R703
R705
R701
C703
IC701
C731
R706
C
703
C743
C744
C
4
2
R709
R710
R708
C705
R711
TP
(RF)
J
JW
JW726
C
C747
JW710
9
oscilloscope
(AC range)
[CD BOARD] (Conductor side)
(GND)
TP (RF)
• Abbreviation
   CET  : East European & Russian
   SP     : Singapore
12
CFD-V3/V7/V7L
Adjustment Location :
[MAIN BOARD]
(Component side)
[MAIN BOARD]
(Conductor side)
CT1 : FM Tracking Adjustment
CT3 : AM/LW Tracking Adjustment
L3: AM/LW Tracking Adjustment
CV3: LW Tracking Adjustment (V7L)
T2 : AM/LW IF Adjustment
T1 : FM  IF Adjustment
L2 : FM Frequency Coverage Adjustment
CT4: AM/LW Frequency 
        Coverage Adjustment
CT2 : FM Frequency
          Coverage Adjustment
L4 : AM/LW Frequency 
       Coverage Adjustment
CV2 : LW Frequency Coverage Adjustment 
    (V7L)
L1 : FM Tracking Adjustment
13
CFD-V3/V7/V7L
Pin No.
Pin name
I/O
Description
1 – 4
NC
Not used (open)
5
IC
Connect to ground.
6
XT1
I
Connect to ground.
7
XT2
Not used (open)
8
VDD
Power supply terminal (B+ 3.3 V)
9
VSS
Ground terminal
10
CL1
I
Oscillator terminal (4 MHz)
11
CL2
Oscillator terminal (4 MHz)
12
RESET
I
Reset signal input
13
NC
Not used (open)
14
SYNC–R
Not used (open)
15
CE
O
Chip enable signal output
16
C–RST
O
Reset signal output to the LC78645E (IC701)
17
CAPH
Charge pump capacitor terminal
18
CAPL
Charge pump capacitor terminal
19 – 21
VLC0 – 2
Capacitor connect terminal
22 – 25
COM0 – 3
O
LCD common drive output
26 – 43
S0 – 17
Not used (open)
44 – 48
S18 – 22
O
LCD segment drive output
49
S23
Not used (open)
50
ENTER
I
Key (ENTER) input
51
MODE
I
Key (MODE) input
52
PLAY
I
Key (H PLAY) input
53
FR
I
Key (l FR) input
54
FF
I
Key (L FF) input
55
STOP
I
Key (s STOP) input
56
DOOR
I
Door open/close input
57
WRQ
I
Command signal input
58
TEST
I
Test mode signal terminal input (TEST: L)
59
MUTE
O
Mute signal output
60
FSEQ
I
Frame SYNC signal input
61
DRF
I
DRF (Defect RF) input
62
DO
O
Serial data output
63
DIN
I
Serial data input
64
CLK
I
Clock signal input
SECTION 6
DIAGRAMS
6-1. EXPLANATION OF IC TERMINALS
IC801   
µ
PD789316GK-903  SIGNAL PROCESSOR, D/A CONVERTER, LCD DRIVE, SYSTEM CONTROL
14
CFD-V3/V7/V7L
• Circuit Boards Location
INLET board
BATT (R) board
BATT (L) board
FM SW board
MAIN board
CD board
CONTROL board
VOLUME board
POWER board