Sony CFD-V14 Service Manual ▷ View online
– 9 –
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
done by the trimmer capacitors.
< > : East European model only
[ ] : Italian model only
[ ] : Italian model only
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T2
455kHz
AM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L4
520kHz
[516kHz]
CT4
1,680kHz
[1,630kHz]
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
620kHz
CT3
1,400kHz
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
10.7MHz
FM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L2
87.0MHz
<64.0MHz>
[87.35MHz]
CT2
108.3MHz
<109.5MHz>
[108.25MHz]
VCO Adjustment
Procedure :
1. Connect the frequency counter to 4 and 7 pin of IC 1 as
shown the figure below.
2. Turn the set to 98MHz.
3. Adjust RV1 for 75.95kHz – 76.05kHz reading frequency counter.
3. Adjust RV1 for 75.95kHz – 76.05kHz reading frequency counter.
[ MAIN BOARD] (Conductor side)
Adjustment Location : Main board (See page 10)
FM RF signal
generator
generator
Carrier frequency : 98MHz
Modulation : No modulation
Output level : 100dB
Modulation : No modulation
Output level : 100dB
µ
(100mV )
set
telescopic
antenna
terminal
0.01
µ
F
TUNER SECTION
0dB = 1
µ
V
AM Section
Function switch : AM
Volume
Volume
: MIN
FM Section
Function switch : FM
Volume
Volume
: MIN
AM RF signal
generator
generator
30% amplitude modulation by 400Hz
signal.
Output level : as low as possible
signal.
Output level : as low as possible
Put the lead-wire
antenna close to
the set.
antenna close to
the set.
FM RF signal
generator
generator
22.5kHz frequency deviation by
400Hz signal.
Output level : as low as possible
400Hz signal.
Output level : as low as possible
telescopic
antenna
terminal
antenna
terminal
0.01
µ
F
set
32
Ω
J301 (phones)
level meter
frequency counter
33k
Ω
1
µ
F
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
87.0MHz
<68.0MHz>
[87.35MHz]
CT1
108.3MHz
<102.0MHz>
[108.25MHz]
Adjustment Location : Main board (See page 10)
– 10 –
Adjustment Location
L4 : AM Frequency Coverage Adjustment
L2 : FM Frequency Coverage Adjustment
L1 : FM Tracking Adjustment
T2 : AM IF Adjustment
T1 : FM IF Adjustment
RV1 : VCO Adjustment
[MAIN BOARD]
(Component side)
(Component side)
L3 : AM Tracking Adjustment
[MAIN BOARD]
(Conductor side)
(Conductor side)
CT1 : FM Tracking Adjustment
CT3 : AM Tracking Adjustment
CT4 : AM Frequency Coverage Adjustment
CT2 : FM Frequency Coverage Adjustment
CD SECTION
•
Note :
Non Adjustment
How to put the set into CD Test Mode
1. Set the function switch to power off.
2. Set the function switch to CD while
2. Set the function switch to CD while
≠ key and p key pressing.
The set is into CD test mode (
The set is into CD test mode (
88 is displayed).
3. Turn the power off to release test mode.
– 11 –
Pin No.
Pin name
I/O
Description
1
SEIN
I
CD SENS input.
2
CNIN
I
CD SENS input.
3
DATO
O
CD DSP command data output.
4
XLTO
O
Latch output.
5
CLKO
O
Clock output for CD DSP command.
6
DV
SS
–
Digital ground.
7
DV
DD
–
Digital power supply (+5V).
8
MON
–
Not used (Open).
9
MDP
O
Spindle motor drive control.
10
MDS
–
Not used (Open).
11
LOCK
O
Lock signal output.
12
VPCO2
–
Not used (Open).
13
VPCO1
–
Not used (Open).
14
VCKI
–
Not used (Connect to !∞ pin).
15
V16M
–
Not used (Connect to !¢ pin).
16
VCTL
–
Not used (“H” level).
17
PCO
O
Decoder PLL phase comparator output.
18
FILI
I
Decoder PLL filter input.
19
FILO
O
Decoder PLL filter output.
20
AV
SS
–
Analog ground.
21
CLTV
I
Decoder PLL VCO control voltage input.
22
AV
DD
–
Analog power supply (+5V).
23
RF
I
CD RF signal input.
24
BIAS
I
Playback EFM asymmetry current constant input.
25
ASYI
I
Playback EFM asymmerty comparater voltage input.
26
ASYO
O
Playback EFM full swing output.
27
TEST1
I
Test terminal (Fixed at “L”).
28
TEST2
I
Test terminal (Fixed at “L”).
29
XRST
I
CD reset input.
30
XRSTO
O
CD reset output. “L” : Reset
31
FOK
I
FOK signal input.
32
LRCK
O
L/R clock signal output.
33
LRCKI
I
L/R clock signal input.
34
PCMD
O
PCM data output.
35
PCMDI
I
PCM data input.
36
BCK
O
Bit clock signal output.
37
BCKI
I
Bit clock signal input.
38
GTOP
–
Not used (Open).
39
XPCK
–
Not used (Open).
40
GFS
–
Not used (Open).
41
RFCK
–
Not used (Open).
42
C2PO
–
Not used (Open).
43
DV
SS
–
Digital ground.
44
DV
DD
–
Digital power supply (+5V).
45
XROF
–
Not used (Open).
SECTION 6
DIAGRAMS
6-1. EXPLANATION OF IC TERMINALS
IC702 CD DIGITAL SIGNAL PROCESSOR, LED DRIVE, SYSTEM CONTROL (CXP401-601R)
– 12 –
Pin No.
Pin name
I/O
Description
46
MNT3
–
Not used (Open).
47
MNT1
–
Not used (Open).
48
MNT0
–
Not used (Open).
49
C4M
–
Not used (Open).
50
DOUT
–
Not used (Open).
51
EMPHI
–
Not used (Open).
52
WFCK
–
Not used (Open).
53
SCOR
–
Not used (Open).
54
SBSO
–
Not used (Open).
55
EXCK
–
Not used (Open).
56
DTEST
I
Test terminal (Fixed at “L”).
57
CTEST
I
Test terminal (Fixed at “L”).
58
FR
I
≠ key input.
59
PLAY/PAUSE
I
fl key input.
60
FF
I
± key input.
61
STOP
I
p key input.
62
MODE
I
PLAY MODE key input.
63
DISP/ENTER
I
DISPLAY/ENTER key input.
64
AU MUTE
O
Audio mute signal output.
65
BTL MUTE
O
BTL mute signal output.
66
SENSE2
I
CD SENSE input.
67
REC
I
Function REC input.
68
LIMIT SW
I
LIMIT switch input.
69
OPEN/CLOSE
I
CD door open/close switch input.
70
RMC
–
Not used (Fixed at “H”).
71
DV
SS
–
Digital ground.
72
DV
DD
–
Digital power supply (+5V).
73
SEG 15
–
Not used (Open).
74
SEG 14
–
Not used (Open).
75 – 88
SEG 1 – 13
O
LCD segment output.
89 – 92
COM 0 – 3
O
LCD common output.
93 – 95
VCL 1 – 3
I
LCD drive device voltage input.
96
AV
SS
1
–
Analog ground.
97
AV
DD
1
–
Analog power supply (+5V).
98
AOUT1
O
Audio output.
99
AIN1
I
Audio input.
100
LOUT1
O
L-CH audio output.
101
AV
SS
1
–
Analog ground.
102
XV
DD
–
Oscillator power supply (+5V).
103
XTAI
I
Oscillator connect terminal (16.9344MHz).
104
XTAO
O
Oscillator connect terminal (16.9344MHz).
105
XV
SS
–
Oscillator ground.
106
AV
SS
2
–
Analog ground.
107
LOUT2
O
R-CH audio output.
108
AIN2
I
Audio input.
109
AOUT2
O
Audio output.
110
AV
DD
2
–
Digital power supply (+5V).
111
AV
SS
2
–
Ground terminal.
112
NC
–
Not used (Open).
Click on the first or last page to see other CFD-V14 service manuals if exist.