Sony CFD-S700 Service Manual ▷ View online

13
CFD-S700
jack (J321)
set
32 
test tape
WS-48A
(3 kHz, 0 dB)
digital frequency
counter
  TAPE SECTION     0 dB = 0.775 V
• Standard Output Level
Output terminal
HP OUT
load impedance
32 
output signal level
0.25 V (–10 dB)
• Test Tape
Type
Signal
Used for
WS-48A
3 kHz, 0 dB
tape speed adjustment
Tape Speed Adjustment
Procedure:
Mode: playback
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened
swab :
record/playback head
pinch roller
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head demagne-
tizer. (Do not bring the head magnetizer close to the erase head.)
3. Do not use a magnetized screwdriver for the adjustments.
4. The adjustments should be performed with the rated power
supply voltage (9V) unless otherwise noted.
Torque Measurement
Mode
Torque meter
Meter reading
2.95 – 6.86 mN • m
FWD
CQ-102C
(30 – 70 g • cm)
(0.42 – 0.97 oz • inch)
FWD
0.15 – 0.53 mN • m
Back Tension
CQ-102C
(1.5 – 5.5 g • cm)
(0.021 – 0.076 oz • inch)
more than 5.88 mN • m
FF
CQ-201B
(more than 60 g • cm)
(more than 0.83 oz • inch)
more than 5.88 mN • m
REW
CQ-201B
(more than 60 g • cm)
(more than 0.83 oz • inch)
Tape Tension  Measurement
Mode
Tension meter
Meter Reading
FWD
CQ-403A
more than 100 g
(more than 3.53 oz)
SECTION 5
ELECTRICAL ADJUSTMENTS
SECTION 4
MECHANICAL ADJUSTMENTS
Adjust so that the value on the digital frequency counter is
3,000 Hz.
Specification Value:
Digital frequency counter
2,940 to 3,060 Hz
Adjust so that the frequency at the beginning and that at the end of
tape winding are between 2,970 to 3,030 Hz.
Adjustment Location:
Tape speed adjustment 
control inside motor
14
CFD-S700
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T2
10.7 MHz
FM FREQUENCY COVERAGE
ADJUSTMENT
Frequency Display
87.5 MHz
108 MHz
Reading on Digital voltmeter
1.3 ± 0.3 V
3.0 ± 0.2 V
Adjustment Part
<confirmation>
L2
FM TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
CT1
87.5 MHz
108 MHz
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
450 kHz
AM FREQUENCY COVERAGE
ADJUSTMENT
Frequency Display
530 kHz
1,710 kHz
Reading on Digital voltmeter
1.0 ± 0.1 V
5.3 ± 0.7 V
Adjustment Part
L4
<confirmation>
AM TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
CT3
620 kHz
1,400 kHz
digital
voltmeter
100 k
TP (VT)
i
 jack (J321)
set
32 
level meter
(range: 0.5–5 V ac)
Put the lead-wire
antenna close to
the set.
AM RF signal
generator
  TUNER SECTION     0 dB = 1 µV
• FM Section
Setting:
RADIO (BAND) button: FM
75 kHz frequency
deviation by 1 kHz signal
output level : as low as possible
• AM Section
Setting:
RADIO (BAND) button: AM
30% amplitude
modulation by
400 Hz signal
• Connecting Level Meter (FM and AM)
• Connecting Digital Voltmeter (FM and AM)
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
Adjustment Location: 
See page 15.
TP (JW1)
FM RF signal
generator
0.01 
µ
F
set
15
CFD-S700
TP
(RF)
TP
(FE)
TP
(TE)
TP
(VREF)
TP
(RF)
TP
(VREF)
– CD board (conductor side) –
Adjustment Location:
  CD SECTION
CD section adjustments are done automatically in this set.
In case of operation check, confirm that focus bias.
Focus Bias Check
1. Connect the oscilloscope between IC701 pin 4 and pin qa (or
TP (RF) and TP (VREF).
2. Insert the disc (YEDS-18). (Part No. : 3-702-101-01)
3. Press the CD N X button.
4. Confirm that the oscilloscope waveform is as shown in the
figure below. (eye pattern)
A good eye pattern means that the diamond shape (     ) in the
center of the waveform can be clearly distinguished.
• RF signal reference waveform (eye pattern)
Test Point:
RF level :
0.85 
±
 0.2 Vp-p
VOLT/DIV : 50 mV (10 : 1 probe in use)
TIME/DIV : 500 nS
When observing the eye pattern, set the oscilloscope for AC range
and raise vertical sensitivity.
– MAIN board (component side) –
T2
FM IF
ADJUSTMENT
T2
L2
TP(JW1)
T1
AM IF
ADJUSTMENT
T1
L4
L3
CT1
CT3
L1
L2
FM  FREQUENCY
COVERAGE
ADJUSTMENT
CT1, L1
FM  TRACKING
ADJUSTMENT
L4
AM
FREQUENCY
COVERAGE
ADJUSTMENT
CT3, L3
AM
TRACKING
ADJUSTMENT
16
CFD-S700
6-1. IC Pin Description
• IC802  uPD789477GC-A06-8BT (SYSTEM CONTROLLER)
Pin No.
Pin Name
I/O
Pin Description
1, 2
NC
Not used. (Open)
3 – 5
VLC2 – 0
O
LCD drive voltage output
6 – 9
COM0 – 3
O
LCD drive common output
10 – 26
S0 – 16
O
LCD drive segment output
27 – 29
S17 – 19
O
LCD drive segment output     Not used. (Open)
30
BL-CONT
Not used. (Open)
31
A-MUTE
O
Audio mute output    H: Mute
32
WB/FM.AM.TV
O
Tuner output level attenuator switch     Not used. (Open)
33
DBB
O
MEGA BASS control output     H: MEGA BASS off, L: MEGA BASS on
34
P-CON
O
System power control output     H: PCON
35
AC-CHK
I
AC power supply detection signal input  “L”: AC in
36
CD
O
CD function output    H: CD
37
TAPE
O
Tape function output    H: Tape
38
AVDD
Analog power supply pin for A/D converter (+3.3 V)
39
BTT-CHK-H
I
Battery check input for Hi-voltage
40
BTT-CHK-M
I
Battery check input for Mid-voltage
41
REC
I
Tape record signal input    H: REC
42 – 45
KEY1 – 4
I
Key input
46
MODE CHK
I
Mode set input
47
AGND
Analog GND for A/D converter
48
REMOTE
I
Sircs receiver data input
49
TC-PLAY
I
Tape play switch input    L: Tape
50
WP/INI
O
Initial set signal output
51
CD-DOOR
I
CD door open/close switch input    L: Close
52
C-WRQ
I
CD command data input
53
C-DOUT
I
CD sireal data input
54
C-DIN
O
CD sireal data output
55
C-CLK
I
Serial data transfer clock signal input
56
R-COUNT
I
Tuner PLL data input
57
R-DATA
O
Tuner PLL data output
58
R-CLK
O
Tuner PLL clock output
59
R-LAT
O
Tuner PLL latch output
60
B-MUTE
O
Tuner mute signal output     H: Mute
61
C-DRF
I
CD DRF signal input
62
C-CE
O
CD  SENSE read clock output
63
C-FSEQ
I
CD frame SYNC input
64
C-XRT
O
CD system reset output
65
V-LAT
O
Volume latch output     Not used. (Open)
66
V-DATA
O
Volume data output
67
V-CLK
O
Volume clock output
68
SUR
O
Surround switch signal output
69
ICO
Connected to GND
70
XT1
I
Sub system oscillation input (32.768 kHz)
71
XT2
O
Sub system oscillation output (32.768 kHz)
72
VDD
Main power supply pin for A/D converter (+3.3 V)
73
VSS
Main GND
74
X1
I
Main system oscillation input (4.19 MHz)